A5 TIG Orbital System 75© Kemppi Oy 2016 1615
OPERATING MANUAL
A
9. Press the Conrm button.
10. Make a second test weld. Repeat the adjustment
process as necessary.
If the weld is excessively wide and the OD is concave,
decrease the amperage by a percentage and make another
test weld. The correction percentage appears on the main
screen as a digit (+ amps) or as a minus digit (- amps).
3.5.12 Icons and screens during welding
Various screens display during welding to indicate the
function in progress.
21
3 4
1. Pre-purge
Press Start Weld on the weld head to initiate the weld
sequence. Purging of gas inlet hose and weld head with
argon occur for a preprogrammed time in seconds.
Remaining time is displayed.
2. Arc ignition and weld progress
The electrode does not start to rotate immediately
following arc ignition. This delay allows the arc to penetrate
to the tube I.D. The delay time is determined by the tube
wall thickness dimension. The electrode in the graphic
rotates at the same speed as the actual electrode.
3. Post-purge
Following weld completion, the purge gas continues to
ow for a predetermined time. This is to allow the weld to
cool adequately to prevent oxidation of the stainless weld.
Do not open the weld head during post-purge.
4. Weld cycle completed
You can now remove the weld head from the workpiece.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A5 TIG Orbital System 75 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A5 TIG Orbital System 75 in the language / languages: English as an attachment in your email.

The manual is 2,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info