A3 MIG Welder© Kemppi Oy 2018 1826
INTEGRATION GUIDE
5. DIGITAL ROBOT INTERFACE
5.1 Control functions
The control functions are bit elds (values) and single bits
(signals) in the I/O table. They are set by a robot and read
by the welding system.
Table 6.1: Control functions in the A7 MIG Welder system
Function Bits
Value range
Min.
Max.
Units
Control values
WireFeedSpeed 16 10 250 0.1 m/min
Voltage 16 100 480 0.1 V
FineTuning 16 0 100 0.1
MemoryChannel 8 0 89 1
Control signals
SimulationMode 1
StartWelding 1
WireInch 1
WireRetract 1
GasBlow 1
TouchSensorToolSel 1
TouchSensorOn 1
OnlineControl 1
Watchdog 1
ErrorReset 1
5.1.1 WireFeedSpeed
This 16-bit function controls the wire feed speed during
welding. The value is given in scaled or non-scaled mode,
depending on the user setup.
In non-scaled mode:
The minimum setup value is 10 (1.0 m/min).
The maximum setup value is 250 (25.0 m/min).
The minimum step is 1 (0.1 m/min).
In scaled mode:
The minimum setup value is 0 (0.0 m/min).
With this value, the welding system limits the
minimum speed to 1.0 m/min.
The maximum setup value is the robot scaling
value, which is interpreted as 25.0 m/min.
The minimum step is 1. The wire feed speed value
is calculated from the setup value by means of
the value scaling formula.
This value has an eect only when the OnlineControl
signal is set (1), and it overrides the corresponding memory
channel value. If the OnlineControl signal is cleared (0), the
wire feed speed from the active memory channel is used.
5.1.2 Voltage
This 16-bit function controls the welding voltage for the
MIG process. For other processes, the FineTuning function
is used instead. The value is given in scaled or non-scaled
mode, depending on the user setup.
In non-scaled mode:
The minimum setup value is 100 (10.0 V).
The maximum setup value is 480 (48.0 V).
The minimum step is 1 (0.1 V).
In scaled mode:
The minimum setup value is 0 (0.0 V). With this
value, the welding system limits the minimum
voltage to 10.0 V.
The maximum setup value is the robot scaling
value, which is interpreted as 48.0 V.
The minimum step is 1. The voltage is calculated
from the setup value by means of the value
scaling formula.
The value has an eect only when the OnlineControl
signal is set (1), and it overrides the corresponding memory
channel value. If the OnlineControl signal is cleared (0), the
value from the active memory channel is used.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A3 MIG Welder at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A3 MIG Welder in the language / languages: English as an attachment in your email.

The manual is 2,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info