Operation
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted ope-
ration in the first 3 minutes. This is to protect the unit.
Operation will automatically start after 3 minutes.
POWER MANAGEMENT feature (on some models)
When the ambient temperature is lower than the set-
ting temperature for a period of time, the unit will be au-
tomatically operate power management feature. The
compressor and fan motor stop. When the ambient
temperature is higher than the setting temperature, the
unit will be automatically quit the power management
feature. The compressor and (or) fan motor run.
NOTE: For unit with power management light, the light
will illuminate under this feature.
Water drainage
- During dehumidifying modes, remove the upper drain
plug from the back of the unit, install the drain con-
nector (5/8” universal female mender) with 3/4” hose
(locally purchased). For the models without drain
connector, just attach hose to the hole. Place the
open end of the hose directly over the drain area in
your basement.
- When the water level of the bottom tray reaches a
predetermined level, the unit beeps 8 times, the digi-
tal display area shows “P1”. At this time
the air conditioning/dehumidification
process will immediately stop. Howe-
ver, the fan motor will continue to ope-
rate (this is normal). Carefully, move
the unit to a drain location, remove the
bottom drain plug and let the water dra-
in away. Reinstall the bottom drain plug
and restart the machine until the “P1” symbol disa-
ppears. If the error repeats, call for service. NOTE: Be
sure to reinstall the bottom drain plug firmly to prevent
leakage before using the unit.
SCALE 0.500
Remove the
upper drain
plug
Continuous
drain hose
- During heating pump mode, remove the lower drain
plug from the back of the unit, install the drain con-
nector (5/8” universal female mender) with 3/4” hose
(locally purchased). For the models without drain
connector, just attach the drain hose to the hole. Pla-
ce the open end of the hose adaptor directly over the
drain area in your basement floor.
NOTE: Make sure the hose is secure so there are
no leaks. Direct the hose toward the drain, making
sure that there are no kinks that will stop the warter
flowing. Place the end of the hose into the drain and
make sure the end of the hose is down to let the water
flow smoothly. (See Figs with ). Do never let it up
(See Figs. with ). When the continuous drain hose
is not used, ensure that the corresponding drain plug
and knob are installed firmly to prevent leakage.
SCALE 0.500
Remove the
lower drain plug
Continuous
drain hose
Drain hose
adaptor
SCALE 0.500
X
.
Drain hose
adaptor
Drain hose
adaptor
Press the power
cord buckle into
the rear cover
delivery lift ≤ 1.8m
SCALE 0.500
Maintenance
WARNING
- Always unplug the unit before cleaning or servicing.
- DO NOT use flammable liquids or chemicals to clean
the unit.
- DO NOT wash the unit under running water. Doing so
causes electrical danger.
- DO NOT operate the machine if the power supply was
damaged during cleaning. A damaged power cord
must be replaced with a new cord from the manufac-
turer.
Clean the Air Filter
SCALE 0.500
Upper filter
(take out)
Remove
the screw,
then take
the lower
filter out
Remove the air filter
CAUTION
DO NOT operate the unit without filter becayse dirt
and lint will clog it and reduce performance.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun KP-35 HP10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun KP-35 HP10 in the language / languages: English as an attachment in your email.

The manual is 2,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun KP-35 HP10

Kaysun KP-35 HP10 User Manual - German - 20 pages

Kaysun KP-35 HP10 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info