771578
25
Zoom out
Zoom in
Previous page
1/64
Next page
25
8 - ELECTRICAL CONNECTIONS
8.1 - ELECTRICAL WIRINGDIAGRAM - 190
T3: Evaporator temperature sensor
T4: Ambient temperature sensor
T5U: Storage tank temperature sensor (Upper)
T5L: Storage tank temperature sensor (Lower)
TP: Discharge temperature sensor
TH: Suction temperature sensor
Item Content
CAP1 Fan capacity
CN1-40 Terminal base
TR Transformer
1A-1B-1D-1F Connected wires inside of the tank
CT1 Zero-phase electricity mutual inductor
CT2 AC mutual inductor
RY1,3 Relay connecting wires
KM1,KM2 Relay
TCO Temperature protective switch
UE Electric heater of the tank
XT1,XT2 Mid terminal base
ATCO Automatic temperature recover switch
EVV Electric expansive valve
Wiring diagram of
tank inside
1A/1B/1D/1F wire comes out from tank,must connect with the corresponding component.
Power supply
The L,N wires,which get through
the zero-phase electricity mutual
inductor, must keeping the sam
direction during wring,
otherwise, system malfunction
may caused.
MAIN CONTROL PANEL
SW1
ON OFF
SW1_1 Without Electric Heater With Electric Heater
SW1_2 Without Disinfect With Disinfect
Model selection(User never allow to alter the factory
settings)
SW2
ON OFF
SW2_1 300L model 190L model
SW2_2 Power furquency_60Hz Power furquency_50Hz
Model selection(User never allow to alter the factory
settings)
T3 Evaporator temperature sensor
T4 Ambient temperature sensor
T5U Tank temperature sensor (Upper)
T5L Tank temperature sensor (Lower)
TP Discharge temperature sensor
TH Suction temperature sensor
If the custom needs to install the solar energy coils, the the
CN26 terminal needs to be connected with the 220~240V
power supply. The CN2 supplies the control signal for the
solar energy water pump, and the water pump must be
controlled by the AC contactor, as the CN2 terminal should
not drive the water pump directly.
Please contact distributor technicians for wiring method
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun COMPAK KHPA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun COMPAK KHPA in the language / languages: English as an attachment in your email.

The manual is 14.06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info