5
Air inlet
Air outlet A
B
C
C
D
D
Air outlet B
Air inlet
Air inlet
Air outlet
A
3.2 Air duct connection
1) Air outlet without duct, air inlet connects to duct.
Fig.3-3
2) Air outlet without duct, air inlet connects to duct. (A+D≤10m)
Fig.3-4
It is recommended to install unit by this way in summer that could
charge fresh air into room.
3) Air outlet connects to duct, air inlet without duct. (B+C≤10m)
Fig.3-5
It is recommended to install unit by this way in the winter where there
is other heat source in the room.
4) Duct Description
Table.3-1
Duct Round duct Rectangle duct Other shaped
duct
Dimension
(mm) Φ190 190X190
Refer to above
data
Straight-line
pressure drop
(Pa/m)
≤2 ≤2
Straight-line
length (m) ≤10 ≤10
Bent pressure
drop(Pa) ≤2 ≤2
Bent’s qty. ≤3 ≤3
50mm larger than
the dia. of unit
Max.22mm
Heat Pump
Water Heater
User
Water Inlet
Anode rod
Drainpipe
Barrel-drain
Expansion Tank for tank
(if required)
Upper
Condensate Outlet
Lower
Condensate Outlet
Notice:
The temperature limiting
valve is required on the
hot water usage terminal.
PTR valve
Water Outlet Temp. Limiting
Valve
Tap Water
One Way Valve
Shut-off Valve
Anode rod
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun COMPAK KHP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun COMPAK KHP in the language / languages: English as an attachment in your email.

The manual is 2.84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info