15-80 ELECTRICAL SYSTEM
Junction Box
Diode Circuit Inspection
Remove the junction box.
Set the hand tester to the × 1 k range.
Check the continuity between the following terminals in
both directions:
Diode Circuit Inspection
Tester
Connection
13-8*, 13-9*, 12-11, 12-14, 15-14, 16-14
*: EJ650-A1 A4/C3 C4, Canada and Australia Mod-
els only.
EJ650-A5/C5 C7, C6F, All Models.
EJ650-A5/C5, All Models.
If there is continuity in one direction (forward direction) but
no continuity (infinity) in the reverse direction, the diode
is normal.
The diode is defective if there is continuity after changing
the direction, or if it remains with no continuity. In this
case, replace the junction box.
Special Tool - Kawasaki Hand Tester: 57001-1394
NOTE
The actual resistance measurement in the forward
direction v aries with the tester used and the individual
diodes. Generally speaking, it is acceptable if the
tester’s indicator swings approximately halfway.
400


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kawasaki W 650 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kawasaki W 650 in the language / languages: English as an attachment in your email.

The manual is 9,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info