-4
Note
The cover is unlocked with the key of the
main switch.
Insert the key for the main switch into
the hood lock and rotate in a clockwise
direction by 90°.
Pull the hood lock out by the key.
Open the device hood.
Close the appliance cover, the cover
lock will lock automatically.
DANGER
Risk of injury, risk of damage!
Observe the weight of the appliance when
you load it!
Remove the cardboard.
Remove the wooden blocks that secure
the wheels and raise the device from
the palette by hand.
Release parking brake.
Loosen the screws.
Align the pushing handle.
Tighten the screws.
Note: Remove the waste container and
move the pushing handle to the front prior
to tilting the appliance. Do not rest the ap-
pliance on the pushing handle.
Clip side brush on to driver and screw
on.
Please observe the following warning notes
when handling batteries:
Danger
Risk of explosion! Do not put tools or similar
on the battery, i.e. on the terminal poles
and cell connectors.
Danger
Risk of injury! Ensure that wounds never
come into contact with lead. Always clean
your hands after having worked with batter-
ies.
DANGER
Risk of fire and explosion!
–Smoking and naked flames are strictly
prohibited.
–Rooms where batteries are charged
must have good ventilation because
highly explosive gas is emitted during
charging.
Danger
Danger of causticization!
–Rinse thoroughly with lots of clear water
if acid gets into the eye or comes in con-
tact with the skin.
–Then consult a doctor immediately.
–Wash off the acid If it comes in contact
with the clothes.
* Appliance requires 2 batteries
** in m3
*** in m3/h
Note
With the KM 75/40 W Bp Pack the battery
and the charger are already built in.
Open the device hood.
Set the batteries on to the motor carrier.
Secure the batteries with the holding
strap.
Connect pole terminal (red cable) to
positive pole (+).
Fit the connection wires to the batteries.
Connect pole terminal to negative pole
(-).
Note: Check that the battery pole and pole
terminals are adequately protected with
pole grease.
Only use batteries with terminal cover. Re-
store terminal cover in the event of loss.
CAUTION
Charge the batteries before commissioning
the machine.
Open the device hood.
Close device hood
Before Startup
Unloading tips
Net weight (transport weight)
KM 75/40 W Bp 79 kg
KM 75/40 W Bp Pack 125 kg
Permissible overall weight
KM 75/40 W Bp 205 kg
KM 75/40 W Bp Pack 205 kg
Unloading
Installing the pushing handle
Install side brush
Batteries
Safety notes regarding the batteries
Observe the directions on the
battery, in the instructions for
use and in the vehicle operat-
ing instructions!
Wear an eye shield!
Keep away children from acid
and batteries!
Risk of explosion!
Fire, sparks, open light, and
smoking not allowed!
Danger of causticization!
First aid!
Warning note!
Disposal!
Do not throw the battery in the
dustbin!
Recommended batteries
Order No. Volume Air
stream
60 Ah,
Mainte-
nance-
free
6.654-
226.0*
1,65** 0,66***
Maximum battery dimensions
Length Width Height
267 mm 177 mm 190 mm
Recommended chargers
Order No.
Charger 6.654-225.0
Installing and connecting the batteries