English 15
chapter Dedusting the filter) or replaced
(see chapter Replacing the filter). The var-
ious different hose cross-sections allow ad-
aptation to the various different connection
cross-sections of the accessories.
Initial startup
WARNING
Danger from dust that is harmful to your
health
Respiratory sicknesses through inhalation
of dust.
Do not vacuum without correctly installed
filter elements, otherwise a danger to
health from increased fine dust emission is
present.
ATTENTION
Missing filter element
Damage to the suction motor
Do not vacuum without a filter element.
1. Bring the device into the working posi-
tion.
2. Secure the device with the parking
brakes.
3. Ensure that the suction head is fitted
correctly.
4. Insert the suction hose (not included in
the scope of delivery) into the suction
connection.
5. Make sure that the waste hose is fitted
correctly (see chapter Fitting the waste
hose).
6. Make sure that the disposal system is
used correctly (see chapter Fitting the
disposal system).
7. Attach the desired accessories (not in-
cluded in the scope of delivery) to the
suction hose.
Fitting the waste hose
1. Remove all 4 loops of the waste hose
(length 22 m).
Illustration B
2. Open the holder by turning it to the left
and pull it out downwards.
3. Fit the waste hose.
4. Push the holder in and close it by turning
it to the right.
Illustration C
5. Pull the waste hose 40-50 cm down.
6. Seal the end of the waste hose with a
cable tie.
Operation
The device is suitable for vacuuming fine
dust up to dust class M.
WARNING
Danger from dust that is harmful to your
health
Respiratory sicknesses through inhalation
of dust.
Do not vacuum without correctly installed
filter elements, otherwise a danger to
health from increased fine dust emission is
present.
Note
The device is an industrial vacuum cleaner
for vacuuming dry, non-inflammable dusts
with MAK values 0.1 mg/m3.
Switching on the device
1. Plug the mains plug into the socket.
2. Switch on the device via the suction tur-
bine power switches.
Note
Always switch the suction turbines on and
off one after the other. For the correct func-
tion of the pressure gauge for monitoring
the minimum volume flow, all suction tur-
bines must be switched on.
3. Start the vacuuming process.
Vacuuming process
1. Perform the vacuuming process.
The suction material does not fall into
the waste hose until the device is
switched off.
Regularly check the filling level in the
waste hose because the device does not
switch off automatically.
Illustration D
2. With light suction material or in the case
of clogging, pull the sheathed cable to
filter
(Order no. 9.990-018.0)
Waste hose
(Order no. 6.907-506.0)
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher IVM 40-24-2 M Lp at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher IVM 40-24-2 M Lp in the language / languages: All languages as an attachment in your email.

The manual is 4.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info