Drawing in water from tank
When you suction water out of an open
container you should
disconnect the water inlet at the pump head.
unscrew the top supply hose to the water tank
and connect it to the pump head.
use a water suction hose with a minimum
diameter of 3/4" provided with a vacuum filter.
* Until the pump sucks up water you should:
turn the pressure and flow regulation to MAX.
close the metering valve for the cleaning
agent.
Never suction up water out of a potable water
tank.
Never suction up solvent-bearing liquids such
as paint thinner, benzine, oil or unfiltered
water. The seals in the unit are not resistant
to solvents. The mist of solvents is highly
inflammable, explosive and poisonous!
Mains connection
Refer to technical data and rating plate for
connected loads.
Whenever socket is changed, check
direction of rotation of motor
If direction of rotation is correct, powerful jet of
air will be felt at exhaust-gas opening of burner.
If the direction of rotation is wrong: Change the
poles at the unit plug. See figure 16.
If an extension cable is used, this should always
be fully uncoiled and have an adequate cross-
section.
OPERATION
Switch the unit on
Set the unit switch (item 23) to "I"
The ready for working indicator lamp (item 29)
is lit
The temperature regulator (item 24) must be at
setting "0", since it is otherwise possible that the
burner switches itself on
Unit starts up briefly and is switched off as soon
as operating pressure is reached.
* Turn the unit off immedediately if during its
operation the indicator lamps
(item 25-item 28) light up. Eliminate fault,
refer to Faults.
Figure 8
Release handgun
Actuation of handgun switches unit back on
again.
Bleed pump if no water emerges from high-
pressure nozzle. Refer to Faults "No build-up of
pressure by unit"
Setting cleaning temperature
Set the temperature regulator (item 24) to the
required temperature
30°C to 90°C
Hot water cleaning
100°C to 150°C
Clean with steam, with steam nozzle -
4.766-023, at HDS 1195 and HDS 1295 -
4.766-024
Setting operating pressure and flow rate
Figure 9
Turning regulator clockwise: Increases
operating pressure (MAX)
Turning counter-clockwise: Reduces operating
pressure (MIN)
Servopress control
Set the temperature regulator (item 24) to
max. 9C.
Set regulator to maximum operating pressure.
Figure 8
Operating pressure and flow rate can be set at
handgun.
Set pressure on unit if use is to be made of
reduced pressure for a lengthy period.
See figure 9
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher HDS 745 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher HDS 745 in the language / languages: English as an attachment in your email.

The manual is 3,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info