- 6
You can sign with your dealer a contract for
regular safety inspection or even sign a
maintenance contract. Please take advice
on this matter.
Safety inspection/ maintenance
contract
Maintenance schedule
Time Activity Assembly affected Performance of whom
daily Check hand-
spray gun
Hand spray gun Check whether the hand-spray gun closes tightly
without any leaks. Check the protection mechanism
against accidental switching. Replace defective
hand-spray guns.
Operator
opinion Power cord
(Only with appliance versions
with power cable and mains
plug).
Check the mains cable regularly for damage such as
aging or formation of cracks. If you find a damage,
then the cable must be replaced before using it any
further.
Operator/
Customer
Service
Test fill level Detergent tank, Installation wa-
ter softener (optional)
Check filling level, refill if necessary. Operator
Check high pres-
sure hoses
Outlets, hoses towards working
machine
Check hoses to see if there are damages. Replace
defect hoses immediately. Danger of accident!
Operator
weekly or after
40 operating
hours
Check the unit for
leaks
Entire plant Check pumps and pipes for leaks. Inform Customer
Service if there is oil loss or if there is a leakage of
more than 10 drops of water per minute.
Operator/
Customer
Service
Check oil level Oil tank at the pump If the oil is milky, it needs to be replaced. It is recom-
mended likewise in this case that the pump's oil seal
be changed (Customer Service).
Operator/
Customer
Service
Check oil level Oil tank at the pump Check oil level of the pump. Refill oil if required (Or-
der no. 6.288-016)
Operator
Clean filter Filter at the detergent suck hose Clean filter at the detergent suck hose. Operator
Test vibration
dampener
Vibration dampener If the vibration of the pump increases it indicates that
the pressure tank is defective. Replace the vibration
dampener.
Customer
Service
monthly or after
200 operating
hours
Cleaning the
sieve
Sieve in water inlet Check, dismantle sieve and clean it. Operator
Test swimmer
valve
Float tank When the swimmer valve is closed no water can es-
cape the overflow.
Operator
Test automatic
start
Pressure switch Pump is at a standstill, because no water removal
has taken place. Turn on the hand spray gun. If the
pressure in the high pressure network falls below 3
MPa, the pump must be turned on.
Operator
Tighten hose
clips
All hose clips Tighten the hose clips using a torque wrench. Tight-
ening torque up to a diameter of 28 mm = 2Nm, from
29 mm = 6 Nm.
Operator
annually or after
1000 operating
hours
Oil change High-pressure pump Drain off oil. Refill oil. Check oil level in the oil tank. Operator
Check unit for
calcium deposits.
entire water system Improper functioning of valves or pumps can be an
indication of calcium deposits. If necessary decalcify.
Operator
trained in de-
calcification
annual Safety check Entire plant Safety check according to the guidelines for fluid
spraying equipment.
Technical ex-
pert
23EN
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher HD 7-16-4 ST at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher HD 7-16-4 ST in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 11,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info