725302
21
Zoom out
Zoom in
Previous page
1/312
Next page
– 8
Have the maintenance of the device
performed by the customer service.
Change the oil in the high pressure
pump.
For oil type refer to technical specifica-
tions.
Turn out the oil drain screw.
Drain the oil in a collection basin.
Screw in oil drain plug.
Fill in new oil slowly until the centre of
the oil level display.
Note:
Air pockets must be able to leak out.
DANGER
Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
Prior to all work on the appliance,
switch off the appliance and pull the
power plug.
Get the electrical components checked
and repaired only by authorised cus-
tomer service persons.
Contact an authorised customer service
person in case of problems not men-
tioned in this chapter or if you are in
doubt or when you have been explicitly
asked to do so.
The indicator lamps display the operating
states (green) and interruptions (red).
Reset:
Set the appliance switch to "0".
Wait for a while.
Set the appliance switch to "I".
Continuous green:
The appliance is now ready for opera-
tion.
1x blinking green:
Operational readiness has expired after
30 minutes.
The appliance has switched off after 30
minutes of continuous operation (safety
if the high pressure hose bursts).
Continuous red light:
Electrical problems in appliance
Pull out the mains plug.
Call Customer Service.
1x blinking red:
High pressure side is leaky
Check high pressure hose, hose con-
nections and hand spray gun for leaks.
2x blinking red:
Engine overload/overheat
Set the appliance switch to "0".
Allow device to cool down.
Set the appliance switch to "I".
Water pressure is too low
Ensure adequate water line pressure.
3x blinking red:
Fault in the voltage supply
Check main connections and mains
fuse.
4x blinking red:
Power consumption is too high
Call Customer Service.
No power
Check whether the voltage indicated on
the type plate corresponds to the volt-
age of the socket.
Check the mains connection cable for
damages.
Indicator lamp is blinking green
Operational readiness period has ex-
pired. Switch on/off the appliance
again.
The water shortage fuse (option) was
triggered due to low water inlet pres-
sure.
The indicator lamp "lack of water" will il-
luminate.
Check water inlet pressure, minimum
value see "Specifications".
Turn the device switch to "0" and turn
on again to restart the system.
Every 500 operating hours, at least
annually
Oil change
Troubleshooting
Indicator lamp
Operating status display
Fault indication
Appliance is not running
21EN
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher HD 16-15-4 Cage Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher HD 16-15-4 Cage Plus in the language / languages: All languages as an attachment in your email.

The manual is 10,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info