22 Cushion nozzle
23 Crevice nozzle
24 "Filter" indicator lamp
25 Indicator tuft
26 Roller brush
Installation
Install the loose parts for handle provided with the de-
vice before using the device for the first time.
See page 4 for illustrations
1Handle with mains power cable
2Handle metal tube
3Suction pipe and suction hose
1. Open the handle adjustment.
2. Push the metal pipe of the handle into the mount all
the way to the lowest latching position (latches audi-
bly twice).
3. Insert the handle into the metal pipe and latch into
place. Take care to ensure that the mains cable is
not jammed or twisted.
4. Pull the handle to the first (uppermost) latching po-
sition.
5. Close the handle adjustment.
6. Insert the suction hose into the connection nozzle.
7. Insert the suction pipe into the mount on the device
Startup
Installing the filter bag
1. Unlock and remove the filter cover.
2. Turn the filter bag lock to the right to unlock.
3. Insert the filter bag and turn the filter bag lock to the
left to lock.
4. Fit and lock the filter cover.
Connecting the mains power cable to the
device
1. Open the cable holder at the handle.
2. Plug the mains cable provided into the socket on the
device.
3. Secure the plug connection against unintentional
unplugging using the cable holder on the handle.
Use only the mains cable provided and only replace it
with an equivalent cable in the case of damage (see
"Technical data").
Operation
Adjusting the height of the handle
The height of the handle is adjustable.
See page 4 for illustrations
1. Open the handle adjustment.
2. Move the handle up or down to set the desired
height.
3. Close the handle adjustment.
Switching on the device
1. Connect the mains plug.
2. Switch on the device at the main switch.
Electronic brush monitoring
The electronic brush monitoring continuously monitors
the function of the roller brush.
The indicator light shows the respective operating
mode:
Off: Roller brush functioning correctly.
Lights up orange: Incorrect fibre height setting - set
the fibre height selection knob to a lower fibre
height.
Also lights up orange at the lowest setting: Replace
the roller brush.
Note
Visual brush inspection: The degree of wear can be de-
termined by comparing the differently coloured indicator
tufts. Replace the roller brush when the black bristles
are the same height as the red bristles.
Roller brush operation
ATTENTION
Risk of damage to the floor covering!
Do not operate the device continuously at the same
point.
1. Adjust the fibre height using the selection knob on
the brush head.
2. Perform cleaning.
Using accessories
Vacuum with the crevice nozzle and cushion nozzle.
See page 4 for illustrations
1. Pull the suction pipe out of the mount.
2. Remove the desired accessory from the storage
compartment and plug it onto the suction pipe.
3. Perform cleaning.
Suction pipe operation
ATTENTION
Risk of damage!
When vacuuming using the suction hose, allow the de-
vice to latch into position without moving so that the
brush motor switches off and does not damage the car-
pet.
Switching off the device
1. Switch off the device at the main switch.
2. Pull out the mains plug.
Cable storage
The mains cable can be stored on the device.
See page 4 for illustrations
1. Wind the mains power cable onto the winding aid.
2. Wind the mains cable around the cable hook and
handle.
3. To remove the cable, open the cable hook and re-
move the cable from the handle.
Transport
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transporta-
tion.
1. Wind the mains cable around the cable storage.
2. Carry the device by the carrying handle.
3. When transporting the device in vehicles, secure it
to prevent it from slipping or overturning in accord-
ance with the respective valid guidelines.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher CV 38-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher CV 38-2 in the language / languages: All languages as an attachment in your email.

The manual is 9.35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info