804748
19
Zoom out
Zoom in
Previous page
1/296
Next page
English 19
Monthly
Empty and flush the fresh water tank.
Clean the fresh water filter.
Clean the float.
For a temporarily shut-down device with lead-acid
battery: Perform equalization charging of the bat-
tery.
Check battery poles for oxidation, brush off if neces-
sary. Make sure the connection cables are firmly in
place.
Clean the seals between the waste water tank and
the cover, check for leaks and replace if necessary.
Only with R cleaning head: Clean the brush tunnel.
Only with R cleaning head: Pull the water distribu-
tion strip off the cleaning head and clean the water
channel.
Check the acid density of the cells if the lead batter-
ies are not maintenance-free.
For longer downtime periods, shut the device down
with fully charged batteries. Fully charge the battery
at least once a month.
Annually
Have the prescribed inspection performed by Cus-
tomer Service.
Maintenance work
Cleaning the coarse dirt filter
1. Open the waste water tank cover.
Illustration R
1Coarse dirt filter
2. Pull the coarse dirt filter upwards and off.
3. Rinse off the coarse dirt filter under running water.
4. Reinsert the coarse dirt filter into the waste water
tank.
Cleaning the fresh water filter
1. Drain the fresh water.
2. Unscrew the fresh water tank cap.
Illustration S
1Fresh water filter
2Fresh water tank lock
3. Pull out the fresh water filter and rinse with clear wa-
ter.
4. Insert the fresh water filter.
5. Fit the fresh water tank lock.
Turn over or replace the worn suction lips
The suction lips must be turned over or replaced when
worn out.
The suction lips can be turned 3 times until all 4 edges
are worn.
1. Remove the suction bar.
2. Unscrew the star handles.
Illustration T
1Star grip
2Strap
3Inner part of the suction bar
4Tension lock
3. Pull out the inner part of the suction bar.
4. Open the tension lock.
5. Remove the strap.
6. Release the suction lips from the inner part.
Illustration U
1Squeegee blade
2Support lip
3Inner part of the suction bar
4Strap
7. Press the turned or new suction lips onto the knobs
of the inner part of the suction bar.
8. Attach the strap.
9. Push the inner part of the suction bar into the upper
part.
10. Screw in and tighten the star handles.
Replacing the disc brush
Note
Replace the disc brushes when the bristle length has
reached 10 mm.
1. Press the raise/lower cleaning head lever down and
latch it towards the right.
2. Push the brush replacement pedal down.
3. Pull the disc brush sideways and out from under-
neath the cleaning head.
4. Hold the new disc brush under the cleaning head,
then press upwards and latch it into position.
Replacing the roller brushes
Note
Replace the roller brushes when the bristle length has
reached 10 mm.
1. Press the raise/lower cleaning head lever down and
latch it towards the right.
2. Press the Brush replacement button.
Illustration V
1Brush replacement button
2Bearing cover
3Roller brush
3. Pivot the bearing cover to the right.
4. Pull out the roller brushes.
5. Position the new front roller brush in the bearings.
6. Position the new rear roller brush in the bearings.
7. Pivot back the bearing cover and latch it into place.
Cleaning the water distribution strip
1. Push the locking lever to the left and simultaneously
pull the water distribution strip away from the clean-
ing head.
Illustration W
1Water distribution strip
2Locking lever
2. Remove the water distribution strip from the clean-
ing head.
3. Clean the water distribution strip.
4. Fit the left side of the strip into the cleaning head.
5. Pivot the water distribution strip towards the clean-
ing head and latch it into place on the right-hand
side.
Animated maintenance work
Troubleshooting guide
DANGER
Inadvertently starting up device
Risk of injury
Set the program switch to "0" prior to all work on the de-
vice.
Remove the Intelligent Key prior to all work on the de-
vice.
Pull out the charger mains plug.
Drain and dispose of the waste water and fresh wa-
ter.
Contact Customer Service in the case of malfunc-
tions that cannot be corrected using this table.
Malfunctions without information shown on the display
Malfunction Rectification
The device cannot be started 1. Insert the Intelligent Key.
2. Set the program switch to the desired program.
3. Operate the driving lever.
4. Check the batteries and charge if necessary.
5. Check that the battery terminals are correctly connected.
The water quantity is insufficient 1. Check the fresh water filling level and fill the tank if necessary.
2. Increase the water quantity.
aDOSE version: Set the water quantity with the water quantity button on the control panel.
bOther versions: Set the water quantity using the water quantity regulating knob.
3. Clean the fresh water filter.
4. R cleaning head: Clean the water distribution strip.
5. Check the hoses for clogging and clean if necessary.
The suction performance is too low 1. Set the programme switch to NORMAL or INTENSIVE MODE.
2. Set the suction power in the app to HIGH.
3. Shut down the device and drain the waste water.
4. Check that the cap on the waste water drain hose is closed.
5. Clean the seals between the waste water tank and the cover, check for leaks and replace if necessary.
6. Check the turbine screen for soiling and clean if necessary.
7. Clean the suction lips at the suction bar, turn over or replace if necessary.
8. Check the suction hose for clogging and clean if necessary.
9. Check the suction hose for leaks and replace if necessary.
10. Check the adjustment of the suction bar.
11. Hold the waste water tank by the recessed grip and pivot it sideways and upwards.
a Check the seal on the suction turbine.
b Check the seal on the suction duct.
Illustration X
1Suction duct seal
2Suction turbine seal
The cleaning results are unsatisfacto-
ry
1. Reduce the driving speed.
2. Select a more intensive cleaning programme.
3. Check the brushes for wear and replace if necessary.
4. Check the brush for soiling and clean if necessary.
5. Check the suitability of the brush type and detergent used.
6. Check the water supply.
7. Increase the water quantity.
8. Use the two-step method: In the first pass clean without suction, in the second pass clean with suction.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher B50 W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher B50 W in the language / languages: All languages as an attachment in your email.

The manual is 34.13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info