656267
11
Zoom out
Zoom in
Previous page
1/41
Next page
PELLET BURNING STOVES
INSTALLATION AND MAINTENANCE MANUAL
11
The external pipe must have minimum internal dimensions of cm. 10X10 or 10 cm
diameter. cm, and maximum. 20X20 or 20 cm diameter. Check with appropriate tools
that there is a draw of 10 Pa. It must use only, and only pipes insulated (double wall)
within the smooth stainless steel (stainless steel flexible tubes are not allowed) fixed to
the wall, to prevent, and / or minimize condensation problems. At the bottom of the
outer vertical duct an inspection tap for periodic inspections and cleaning to be done
annually. You must ensure that the chimney is installed according to wind force.
This type of connection, even in case of momentary power failure,
ensuring the evacuation of the fumes.
2.8. CONNECTION TO THE FLUE PIPE
The connection between stove and chimney or flue for the proper operation must not be
less than 5% slope in the horizontal sections whose total length should not exceed 1.5
meters. and the vertical by a "T" to another (changing direction) must not be less than 1.5
meters. Check with suitable instruments that there is a minimum draft. of 10 Pa. At the
bottom of the chimney inspected for periodic inspections and cleaning, which must be
conducted annually.
You must ensure that a chimney is installed according to wind force.
This type of connection, even in case of momentary power failure, ensuring
the evacuation of the fumes.
2.9. TROUBLESHOOTING RELATED TO DEFECTS IN THE CHIMNEY FLUE
Of all the meteorological and geographical factors that affect the operation of a flue
(rain, fog, snow, altitude above sea level, period of insulation, exposure to the
cardinal points, etc .) the wind is certainly the most decisive. In fact, besides the
thermal depression caused by the difference in temperature between the inside and
the outside the chimney, there is another type of depression (or overpressure ): the
dynamic pressure induced by the wind. An ascending wind always has the effect of
increasing depression and then the draft. A horizontal wind increases depression for
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Just Fire NB-B18-I at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Just Fire NB-B18-I in the language / languages: English as an attachment in your email.

The manual is 4,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info