636486
49
Zoom out
Zoom in
Previous page
1/116
Next page
Accessories / Services
6 720 645 817 (2010/09)
49
7.5 Boiler safety set
A factory-prepared boiler safety set is available for the
Suprapur KBR ...
This set comprises the following:
Pressure gauge
Safety valve R 1 (for boiler size 120 kW)
Safety valve R (for boiler sizes 160 kW to 280 kW)
Automatic air vent valve
Insulation, grey
Fig. 33 Boiler safety set
7.6 Safety equipment to DIN-EN 12828
As standard, the Suprapur KBR ... is equipped with a low
water indicator (minimum pressure switch) and boiler
drain & fill valve.
Fig. 34 Safety equipment to DIN EN 12828 for boilers
300 kW, operating temperature
105 °C
RK Boiler return
VK Boiler flow
1 Heat source
2 Shut-off valve, flow/return
3 Temperature controller (TR)
4 High limit safety cut-out (STB)
5 Temperature capturing facility
6 Diaphragm safety valve MSV 2.5 bar/3.0 bar or
7 Lift spring, safety valve HFS 2.5 bar
8 Pressure gauge
9 Low water indicator (WMS); not in systems 300 kW,
where instead a minimum pressure limiter or a replacement
measure approved by the manufacturer is provided for each
boiler
10 Non-return valve
11 Boiler drain & fill valve (KFE)
12 Expansion line
13 Shut-off valve - locked to prevent unintentional closure,
e.g. sealed cap valve
14 Drain upstream of diaphragm expansion vessel
15 Diaphragm expansion vessel (DIN-EN 13831)
1) At a shutdown temperature (STB) of 100 °C, the maximum
flow temperature would be 85 °C
The maximum flow temperature drops
through mixing to a lower temperature level
in the low loss header.
Max. boiler
flow
temperature
ΔT on
primary
side of low
loss header
ΔT on
secondary
side of low
loss header
Max. flow
temperature
for heating
system
C] [K] [K] C]
85 25
10 70
15 75
20 80
25 85
85 20
10 75
15 80
20 85
85 15
10 80
15 85
85 10 10 85
Tab. 26 Maximum possible flow temperature when using a
low loss header
6 720 619 235-119.1il
2
9
8
13
15
6/7
10
11
12
13
14
15
2
11
RK
VK
5
1)
4
1)
3
1)
1
300 kW
6 720 642 877-32.1il
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Junkers MKB 400-3 A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Junkers MKB 400-3 A in the language / languages: English as an attachment in your email.

The manual is 15,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info