27
8.4 Concentrisch 80/125
rookgasafvoer langs de gevel en
luchttoevoer onderaan tegen de gevel
8.4 Concentrique 80/125
évacuation des gaz brûlés le long de
la façade et amenée d’air en bas
contre la façade
C53
TABEL EQUIVALENTE LENGTES
TABLEAU LONGUEURS EQUIVALENTES
C 53
gevelmontage (80 mm) **, luchttoevoer onderaan
montage contre la façade (80 mm) **, arrivée d’air en bas
diameter / diamètre
FCX 22 C
FCX 30 C
80 **
9 m
9 m
Op de gevel dient 80 enkel voor rookgasafvoer.
Hier geldt: 1 m buis = 1 m equivalente lengte.
Sur la façade
,
80 ne sert que pour l’évacuation des gaz
brûlés. Ici vaut:
1 m de conduit = 1 m de longueur
équivalente.
Voor de verbinding tussen de ketel en de schoorsteen,
moet een concentrische buis van
80/125 voor
rookgasafvoer en luchttoevoer gebruikt worden.
De eerste
bocht na het toestel is inbegrepen.
Voor de equivalente
lengtes, zie onderstaande tabel.
Pour le raccordement entre la chaudière et la
cheminée, on doit utiliser un conduit concentrique
80/125 pour l’évacuation des gaz brûlés et pour l’amenée
d’air. Le premier coude après la chaudière est inclus. Voir le
tableau ci-dessous pour les longueurs équivalentes.
1 meter buis
1 mètre de conduit
bocht 90°
coude 90°
bocht 45°
coude 45°
bocht 30°
coude 30°
80/125
2 m
4 m
2 m
2 m
** De buitenste buis
125 mm wordt omgekeerd
gemonteerd als bescherming tegen waterinfiltratie.
** Le conduit extérieur
125 mm doit être monté à l’inverse
pour éviter l’infiltration d’eau.
Voor de verbinding tussen de ketel en de gevel, moet een
rookgasbuis van 80/125 gebruikt worden.
Pour le raccordement entre la chaudière et la façade, on
doit utiliser un conduit gaz brûlés de 80/125.
Fig. 25
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Junkers FCX 22 C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Junkers FCX 22 C in the language / languages: Dutch, French as an attachment in your email.

The manual is 8,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Junkers FCX 22 C

Junkers FCX 22 C Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info