Risk of fire!
Grease deposits in the grease filter may
catch fire. The specified safety distances
must be observed in order to prevent an
accumulation of heat. Observe the
specifications for your cooking appliance. If
gas and electric hobs are operated
together, the largest specified distance
applies.
Only one side of the appliance may be
installed directly next to a high-sided unit or
a wall. The distance between the appliance
and wall or high-sided unit must be at least
50 mm.
Risk of injury!
Components inside the appliance may
have sharp edges. Wear protective gloves.
Risk of injury!
The appliance may fall down if it has not
been properly fastened in place. All
fastening components must be fixed firmly
and securely.
Risk of injury!
The appliance is heavy. To move the
appliance, 2 people are required. Use only
suitable tools and equipment.
Risk of electric shock!
Components inside the appliance may have
sharp edges. These may damage the
connecting cable. Do not kink or pinch the
connecting cable during installation.
Risk of electric shock!
It must always be possible to disconnect
the appliance from the electricity supply.
The appliance must only be connected to a
protective contact socket that has been
correctly installed. If the plug is no longer
accessible once the appliance has been
installed, or a fixed connection is required,
the installation must have an all-pole
isolating switch with a contact gap of at
least 3 mm. Only an electrician may install
the fixed connection. We recommend
installing a residual-current circuit breaker
(RCCB) in the appliance's power supply
circuit.
Danger of suffocation!
Packaging material is dangerous to
children. Never allow children to play with
packaging material.
General information
Exhaust air mode
: Risk of death!
Risk of poisoning from flue gases that are drawn back in. The
exhaust air must not be conveyed into a functioning smoke or
exhaust gas flue or into a shaft which is used to ventilate
installation rooms that contain heating appliances. If the
exhaust air is to be conveyed into a non-functioning smoke or
exhaust gas flue, you must obtain the consent of the heating
engineer responsible.
If the exhaust air is conveyed through the outer wall, a
telescopic wall box should be used.
Exhaust duct
Note: The appliance manufacturer does not provide any
warranty for faults attributable to the pipe section.
The appliance achieves its optimum performance by means
of a short, straight exhaust air pipe and as large a pipe
diameter as possible.
As a result of long, rough exhaust air pipes, many pipe bends
or pipe diameters that are smaller than 150 mm, the optimum
extraction performance is not achieved and fan noise is
increased.
The pipes or hoses for laying the exhaust air line must
consist of non-combustible material.
Round pipes
An inner diameter of 150 mm, but at least 120 mm, is
recommended.
Flat ducts
The inner cross-section must correspond to the diameter of the
round pipes.
150 mm diameter, approx. 177 cm
2
120 mm diameter, approx. 113 cm
2
Flat ducts should not have any sharp deflections.
Use sealing strips for different pipe diameters.




24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Junker JD36AE50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Junker JD36AE50 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info