4.5 Travel Adjust (Function Mode)
The purpose of Travel Adjust, also known as endpoint
adjustment or adjustable travel volume, is to offer you precise
servo control deflection in either direction of servo operation.
The travel adjust range is from 0-150% (0 degrees to 60
degrees) from neutral and it can be adjusted for each direction
individually. The factory default (data reset) value is 100% for
each direction of servo travel.
In the Function Mode, use the UP or DN key to select the Travel
Adjust function and access by pressing the UP and DN keys
simultaneously.
Channel being programmed
THRO Throttle
AILE Aileron
ELEV Elevator
RUDD Rudder
GEAR Retract landing gear
FLAP Flap (Aux1)
SPOI Spoiler (Aux2)
AUX3 Extra channel (Aux3)
4.6 Elevator to Flap Mixing (Function Mode)
The upper-most position of the flap mixing switch activates the
Elevator to Flap Mixing Circuitry. When this system is active and
a value of flaps is input, the flaps will be deflected each time the
elevator stick is used. The actual flap movement is independently
adjustable for both up and down elevator. The most frequently
used application is up elevator/down flaps and down
elevator/up flaps. When used in this manner, the aircraft pitches
much more quickly than normal. When you want to reverse the
mixing directions, press the - key and change the mixing value
from + to - (or - to +).
In the Function Mode, use the UP or DN key to select the
Elevator to Flap Mixing function and access by pressing the UP
and DN keys simultaneously.
Note: The flap mixing switch must be in the upper postion to
adjust values.
Elevator operating direction
(D=down, U=up)
SW OFF appears when the
flap mixing switch is in the
middle or lower position
Press the UP and DN keys
simultaneously to enter/exit
the Function Mode
Press the DN and Select keys
simultaneously to access the
Function Mode List Display
Press to increase or
decrease travel value;
move stick or switch to
manipualte arrow to the
position to be adjusted
(high/low, left/right)
Channel
Selection
Reset travel
value to factory
preset (100%)
DN
SELECT
CH CH CLEARUP
To Elevator/Flap
Mixing function
To Sub-Trim
function
Press to display
channels 1-4 and
5-8 (2 screens)
Increase/decrease
applicable mixing
value; move the stick or
switch to manipulate
the arrow to the
position to be adjusted
(up/down)
Reset applicable
mixing value to
factory preset (0)
DN
SELECT
CH CH CLEARUP
To Aileron/Rudder
Mixing function
To Travel Adjust
function
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for JRpropo XP8103 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of JRpropo XP8103 in the language / languages: English as an attachment in your email.

The manual is 2,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info