Initial Delay (INITIAL DELAY)
In order to detect the Signal Pulse from the Brushless motor, it is essential to use ESC, however, certain ESC on
the R/C market o󰮏ers the function to alert initial start with sound of beep. This canbe recognised as a highest
RPM signal on this sensor, So False RPM may appear on the data screen. In order to avoid this false signal
reading, It is capable to set the transmitter to read the signal with some delay between 5seconds to 30seconds
(with 5seconds interval. Initially it is set as INH. Set the required timing by seconds to activate this function.
Altimeter▋(ALTITUDE)
UNIT (SCALE)
This selects the units Meter (m) or Feet (ft). Select the units as
desired.
Sound: Audio (SOUND1,2,3)
It is possible to select from three (3) types of audio for different
altitude indications. Initially it is set to inhibit. If desired, set the alert
sound depending on the situation. It is possible to set altitude between
1 2000m in 1.0 meter increments.
Types of Alert:
: When the altitude is greater than the set value.
: When the altitude is less than the set value.
〜 : When ying within the set altitude range.
When the alert is set in an altitude range, it can be set between 0.3m 〜 9.9m in 0.3m increments.
If the three (3) conditions overlap, Priority is set as “SOUND3 > SOUND2 > SOUND1.
Switch Select (SW SEL)
It is possible to set an Alert to be active by switches or stick position, or a combination of those devices by
using “SW SEL. Initially it is always turned on.
Climb▋Indicator▋(VARIOMETER)
UNIT (SCALE)
This selects the units(m/s, ft/s). Select the units as desired.
Audio for Ascent (UP SOUND1,2,3,4)
The Climb Rate can be set in 4 di󰮏erent ranges, with an alert for each
range. Each one of the setting can have an alert. Initially it is set to
“INH. The Climb Rate alert can be set between 0.1m/s 3.0m/s, in
0.1m/s increments.
If the four (4) conditions overlap, Priority is set as "SOUND4 > SOUND3 > SOUND2 > SOUND1".
Audio for Descent (DOWN SOUND)
The Descent Rate can be set in 4 different ranges, with an alert for each range. Each one of the setting can
have an alert. Initially it is set to “INH”. The Descent Rate alert can be set between 0.1m/s 3.0m/s, in 0.1m/s
increments.
Switch Select (SW SEL)
It is possible to set the Alert to be active by switches or stick position, or a combination of those devices by
using “SW SEL. Initially it is always turned on.
For▋Motive▋Power▋Battery▋(FLIGHT▋PACK)
Motive Power BatteryAlarm (VOLT-ALARM)
It is possible to set an alert for low Motive Power Battery voltage.
Initially it is set as Inhibited. Set the alert voltage as desired. The
Voltage can be set between 0.1V 〜 655.3V in 0.1V increments.
Nominal Capacity Value (CAPACITY)
It is possible to set a Nominal Capacity Value to match your Motive
Power battery capacity. The remaining battery capacity value is
displayed by deducting the consumed capacity value. It can be set
between 0mAh 〜 30,000mAh, in 10mAh increments.
Battery Capacity Alarm (CAPA-ALARM)
It is possible to set a capacity remaining alert based on the Nominal Capacity value of your battery. Initially
it is set as Inhibited. To activate, set a percentage between 0% to 100%. The alarm will sound when this
calculated percent capacity remaining reaches this gure.
Receiver Battery
Voltage
Temperature
Variometer
Motive Power Battery
(Voltage/Capacity)
Rotation Speed
Altitude
System▋List
Receiver Battery
Voltage
Temperature
Variometer
Motive Power Battery
(Voltage/Capacity)
Rotation Speed
Altitude
Receiver Battery
Voltage
Temperature
Variometer
Motive Power Battery
(Voltage/Capacity)
Rotation Speed
Altitude
XG14English.indd 80 2013/07/16 16:41
82


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for JRpropo XG14 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of JRpropo XG14 in the language / languages: English as an attachment in your email.

The manual is 25,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info