5.6 Actions to Deal with Abnormalities and Breakdown
In the case of semiconductor circuits, except in cases of problems in the design or inspection of
such circuits or causes that are external or caused by humans, breakdown or deterioration of the
circuit does not often occur. In general, the causes of breakdown that are relatively frequently
found are wire cut in the high resistance device due to high humidity, defect in the variable
resistance and defective contact of switches and relays.
Moreover, in many cases the cause for breakdown is not a defect in parts but rather poor
adjustment (particularly inadequate tuning adjustment) or poor maintenance (particularly defect in
cable contact) and inspecting or readjusting these aspects is often effective in the case of
perceived abnormality or breakdown. The following table should be taken into consideration in
the case of abnormalities or breakdown.
There is always a cause for blown fuse and after replacing the fuse, it is necessary to
investigate the related circuits even when no abnormality remains. However, consideration
should be given to the fact that there is significant variance in the characteristics of fuse. Please
refer to the list on the fuses used given in Section 9.4.
No. Condition of the Breakdown Conceivable Cause
1 Nothing appears on the
CRT.
a. Breakdown in the power supply unit (CBD-1596)
b. Fuse F1 has blown
c. Breakdown of the monitor
d. Breakdown of the main control circuit (CMC-1156)
e. The electric power of the ship is inadequate.
2 The scanner unit does not
rotate.
a. Fuse F2 has blown
b. Breakdown in the motor unit (JMA-2343: CML-645
H-7BDRD0023 inside the scanner unit, JMA-2344:
CBP-153)
c. Breakdown of the safety switch of the scanner unit
(JMA-2344 only)
3 The scanner unit rotates but
no radar image appears
(characters and markers
are, however, displayed).
a. Breakdown of the receiver (JMA-2343: CAE-457,
JMA2344: CAE-457-1)
b. Breakdown of the main control circuit (CMC-1156).
What is the condition of the transmission trigger (TI)?
c. Breakdown of the motor unit (JMA-2343: CML-645
H-7BDRD0023 inside the scanner unit, JMA-2344:
CBP-153)
4 The operation switches do
not work.
a. If the switches do not work even after turning the power on
again, breakdown in the main control circuit (CMC-1156).
b. Breakdown in the main operation panel circuit
(CCK-873) or soft key panel circuit (CCK-872)
c. Cut in the cable connecting the operation unit.
232


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for JRC JMA2343 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of JRC JMA2343 in the language / languages: English as an attachment in your email.

The manual is 17,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info