631259
3
Zoom out
Zoom in
Previous page
1/10
Next page
The JA-80V LAN / PSTN line communicator - 3 - MKA51202
Function Sequence Options Factory default
Selection of events to report by
phone call
83 M ec x
x=1 report, x=0 no report
M5 & 6 alarms by SMS and call + Set/Unset
by SMS
M7 alarms by call
M8 technical faults by SMS (to installer)
SMS/phone call communication
checking period
84 hhmm
hhmm = hours and minutes in range from
00:00 to 24:00
(The time to wait after the last SMS/phone call
report before performing an SMS/phone
communication check)
24:00
SMS text editing*
Texts can be edited by Comlink software or by SMS instruction:
code TXT n,text,n,text... or by www.GSMLink.cz
via Internet
see 5.4
Enable reporting to phones 80 x
x=0 disabled
x=1 enabled (all programmed by 82.. & 83..)
x=2 enabled without reporting
setting/unsetting by users 41 to 50 (codes,
cards & key-fobs) and master code
setting/unsetting
x=3 only if ARC1 is not responding
x=4 only if ARC1 is not responding
x=1
enabled
Phone number for instant remote
access
902 xx..x 0
xx..x = tel. number (max.20 digits) erased
Remote access 903 x
x=0 disabled
x=1 enabled (by phone and Internet)
enabled
Forwarding of incoming SMSes 926 x
x=0 no, x=1 yes = if the incoming text is not an
SMS instruction it will be forwarded to the first
programmed number in memories M1 to M8
yes
Reaction to incoming calls 904 x
x=0: no reaction
x=1 to 8: answers after 1 to 8 rings
x=9: answers after the 2
nd
call
answers after 5 rings (25s)
Initialisation of GSMLink
communication
913 initialises communication to GSMLink
Tel. number to initialise GSMLink
communication
914 xx..x 0
xx..x = tel. number (max.20 digits) erased
Tx SMS center tel. number
942 xx..x 0
xx..x = tel. number (max.20 digits)
erased
Rx SMS center tel. number
943 xx..x 0
xx..x = tel. number (max.20 digits)
erased
Testing reporting to an ARC 961 a
a=1=ARC1, a=2=ARC2
Test calls to a phone number 962 M M = tel. number memory from 1 to 8
Programming by SMS
System can be programmed remotely via SMS instruction code PRG seq, seq,... where seq is programming
sequence set also from the keypad (e.g. 8080 PRG 08080,201,# set the 10s exit delay)
Triggering LAN re-log-in 935 The communicator will log out of the LAN network and then re-log-in (DHCP update)
Communicator reset 98080 Resets to the factory default settings and erases all phone numbers
Automatic DHCP 930 x
x=0 disabled
x=1 enabled
enabled
Communicator IP address 931 xx..x
xx..x = IP address 12 digits (if automatic
DHCP disabled)
192.168.001.211
Network mask 932 xx..x
xx..x = network mask 12 digits (if automatic
DHCP disabled)
255.255.255.0
Network gateway address 933 xx..x
xx..x = IP address 12 digits (if automatic
DHCP disabled)
192.168.001.001
DNS IP address 934 xx..x
xx..x = IP address 12 digits (if automatic
DHCP disabled)
192.168.001.001
ARC main tel. number/IP address
01 a xx..x 0
ARC backup tel. number/IP
address
02 a xx..x 0
a=1=ARC1, a=2=ARC2, xx..x = IP address &
port for ARC1 – e.g. 01 2 8 192 168 001 123
08080 0 (8= signifies an IP address, it must
have 12 digits followed by a 5 digit port
number).
Tel. number for ARC2 (max.20 digits)
Entering 01p0 or 02p0 will erase the
number/address
erased
Installation (alarm system) ID for
ARC use
03 a zz..z 0
a=1=ARC1, a=2=ARC2, zz..z = ID number
max. 8 digits 0 to 9 and 1=A to 6=F
(hexadecimal number)
0000
Selecting the ARC protocol 04 a x
a=1 ARC1, a=2 ARC2
x=0 CID, x=1 IP CID
CID
Selection of events to report to
ARCs
05 a ec x
a=1 ARC1, a=2 ARC2
ec event code (see 5.26)
x=1 report, x=0 no report
all events are reported
Defining the delay before data is
resent to an ARC
06 a x
a=1 ARC1, a=2 ARC2
x=0 to 9 min. (0=immediately, without delay)
1 minute
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-80V - LAN Communicator at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-80V - LAN Communicator in the language / languages: English as an attachment in your email.

The manual is 0,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info