Examples of setting SMS:
MASTER P2 OUT
- terminal P2 will be set as an output, it is possible to control it via SMS
messages
MASTER P3 OUT INT 20M T3 T4
- terminal P3 will be set as an output, it is possible to control it via SMS
and phone calls from phone numbers TEL3 and TEL4, output will be
switched on for 20 minutes
MASTER RELAY OUT NEG T3 T4
- The output relay is possible to control via SMS and phone calls from
phone numbers TEL3 and TEL4, status of the output will be changed
(ON – OFF - ON) after every call
MASTER P6 OUT INT 3s ALL
- Terminal P6 will be set as output, it is possible to control it via SMS
and phone calls from all phone numbers, phone call will result in
switching the output on for 3 seconds
MASTER P6 OUT INT 48h T1 T2
- Terminal P6 will be set as output, it is possible to control it via SMS
or by phone calls from phone numbers TEL1 and TEL2, phone call
will result in switching the output on for 48 hours
MASTER P6 OUT INT 10s T2 DTMF 1234
- Terminal P6 will be set as output, it is possible to control it via SMS
or by phone calls from phone number TEL2, phone call will result in
switching an output on for 10 seconds. Every incoming phone call will
be answered and if DTMF code “1234” is detected, an output will be
switched on for 10 seconds
MASTER P4 OUT INT 24m DTMF 5678 TEMP 22
- Terminal P4 will be set as output, it is possible to control it via
incoming phone call. If DTMF code “5678” is detected, the output P4
will be switched on for 24 minutes. The output will be switched on if
the temperature is lower than 22 (– 0,5 °C adjustable hysteresis)
MASTER P6 DEL
- it will erase all previous settings for terminal P6. It will be set as an
input, no confirmation SMS will be sent.
3.3. Setting of the phone numbers and data transfer
Store the TEL1 to TEL8 telephone numbers using the below
programming SMS instruction sent from a GSM phone:
MASTER TELX YYY ZZZZZZZ PER
Where:
X is the position, to which the phone number / IP address will
be stored (number 1 to 8)
YYY is the method of sending the information according to table
4
ZZZZZZZ phone number; up to 20 digits, figures 0 – 9, +, *, #,
(+420…, 00420, 602…) can be used; or IP address: Port
(for example 214.55.250.10:8000)
PER
hh:mm Period of regular data transfers, it can be set up to 99
hours and 99 minutes. Text “communicator GD-06 reports:
date and time” is sent. To cancel function of regular data
transfer set 00:00.
Triggering of an input (according to its setting - see 3.1), will cause
the sending of an SMS report, making a phone call or sending data to
the preset phone number or IP address. Method of communication is
programmed for every phone number independently.
Setting method of communication
Parameter Description
SMS SMS message will be sent to the phone number
SMS+
SMS message will be sent to the phone number and
subsequently a phone call will be made to the number.
SMSD
Special data SMS will be sent to the phone number,
suitable for automatic collection of data
GPRS
Data in GPRS format will be sent to preset IP address.
Format of data is equal to SMSD. Setting of other GPRS
parameters is described in chapter 4.5.
CALL
Voice call will be made to selected number
HF-03 Hands Free set must be connected
Limited to 10 minutes max.
Next activation of the input will interrupt actual voice call,
but it will not cancelled the calling of any phone numbers
which has yet to be called and is on queue.
tab. 4
Examples of setting SMS:
MASTER TEL1 SMS 602111733
- Programming of phone number TEL1 to 602111733, reports will be
transferred via SMS
MASTER TEL2 SMSD 602111733 01:30
- Programming of phone number TEL2 to 602111733, messages for
TEL2 will be transferred via SMSD
Status report will be regularly sent to TEL2 on every hour and half
MASTER TEL5 GPRS 214.55.250.10:8000 00:10
- Messages to TEL5 will be transferred via GPRS to IP address
214:55:250:10, port 8000. Status report will be sent every 10 minutes
to this IP address
MASTER TEL4 DEL
- It will erase number TEL4 and all its settings
Format of SMSD and GPRS message:
Serial number # sequence of message # type of device # time # source
of event # event # status of terminals# voltage of terminal P1 # … #
voltage of terminal P6 # power supply voltage # strength of GSM signal
# temperature
- Description of segments of a message (separated by a # )
serial number identification of GD-06 by unique
production number
sequence of message ordinal number of message
type of device 01 for GD-06
time date and time YYYYMMDDHHMMSS
source of event source of event 0=P1 … 5=P6
event 0=deactivation, 1=activation, 2=regular transfer,
3=restoration of GSM (source=0), 3=restoration of AC (source=1)
status of terminals actual status of terminals P1 … P6, RELAY
voltage of terminal P1 … P6 actual voltage of terminals P1 … P6
power supply voltage voltage of the power supply (125=12,5V)
strength of GSM signal strength of GSM signal 1 – 9
temperature temperature measured by device (in °C)
minus temperature -24,9°C =–0249
plus temperature 24,9°C = 00249
Examples of data message:
0301000026#0001#01#20040923103111#00#01#1000000#006#125#1
26#127#125#127#142#08#00244#
3.4. Customization of SMS
The default SMS text can be modified according to needs of the user.
It is possible to send multiple texts in one SMS; individual items must be
separated by commas and a blank space. Texts (name of terminals,
their status…) are case sensitive. Command SMS are not case
sensitive “PUMP” = “pump”.
We recommend using short texts due to the limit of an SMS (160
characters). If a STATUS report is requested and due to long names
the message will be longer than 160 characters then only first 160
characters of the message will be sent.
Device also supports special national symbols – diacritic marks (so
called UNICODE). It is important to keep in mind, that not all mobile
phones neither GSM providers support usage of UNICODE. One SMS
message in UNICODE can contain up to 65 characters. For this reason,
we recommend using only the basic character set without the diacritic
marks.
MASTER TXT index, text, …
Where:
Index is the index according to table 5 and table 6
Text is a new text, which will be saved (next index, text
can continue after comma and blank space)
Texts for status and confirmation SMS after RESET EN
Index Parameters Meaning - description
10
P1 User name of P1 terminal – for
example „PUMP“
11
On P1 terminal is switched on – for
example. „PUMPING“
12
Off P1 terminal is switched off – for
example. „Idle“
20 P2
21 On
22 Off
30 P3
31 On
32 Off
40 P4
41 On
42 Off
50 P5
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron GD-06 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron GD-06 in the language / languages: English as an attachment in your email.

The manual is 0,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron GD-06

Jablotron GD-06 User Manual - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info