555040
2
Zoom out
Zoom in
Previous page
1/6
Next page
GSM car alarm CA-1802 „Athos“ 2/6 MHF57202
phone number field) or by the SMS command “MASTER RESET 1”
which has to be sent to the car alarm’s SIM card number. Performing
a RESET is indicated by 4 beeps. The factory default is MODE 0
without any function assigned, except that the immobilization relay
switches on after the ignition key has been turned on. It is possible to
put the car alarm to RESET 0 mode also in the case, that its
functionality should be cancelled entirely.
By carrying out a RESET, you delete all the car alarm settings as well
as all the previously enrolled remote controllers and wireless sensors.
See configuration table 5.1 for performing any subsequent settings.
5. Enrollment of remote controls and detectors
Up to 4 RC-8x remote controllers and up to 8 JA-8x wireless detectors
can be enrolled. The detectors can be enrolled as either internal or
external. When the car alarm is only partially armed, the detectors enrolled
as internal are excluded from the system (see 8.1 for operating the car
alarm). The external detectors perform protection for every type of arming.
Steps to enroll RC-8x controllers:
1. The car alarm should be disarmed, with the ignition on.
2. Send the SMS instruction MASTER LEARN RC
3. The car alarm beeps 3 times and an LED starts to flash.
4. The RC-8x controller is enrolled by pressing buttons
and
simultaneously for approx. 3 sec. A siren chirp confirms the
enrollment. IBy enrolling the first remote control all other remote controls
previously enrolled will be erased (so enroll all the controllers intended for
use, one by one).
5. Exit enrollment by turning the ignition off. The alarm confirms the enrollment
by sending an SMS message to authorized phones TEL1 to TEL4.
Steps to enroll internal detectors:
1. The car alarm should be disarmed, ignition on.
2. To enroll the internal detectors, send the SMS command MASTER LEARN INT
3. The car alarm beeps 3 times and an LED starts to flash.
4. The detector is enrolled by inserting a battery. By enrolling the first detector
all detectors enrolled as internal will be erased (so, enroll all the detectors
which will be used as internal ones).
5. Exit enrollment by turning the ignition off. The alarm confirms enrollment by
sending an SMS message to authorized phones TEL1 to TEL4.
Steps to enroll external detectors:
1. The car alarm should be disarmed, ignition on.
2. To enroll the external detectors, send the SMS command MASTER LEARN EXT
3. The car alarm beeps 3 times and an LED starts to flash.
4. The detector is enrolled by inserting a battery. By enrolling the first detector all
detectors enrolled as external will be erased (therefore, enroll all the
detectors which will be used as external ones).
5. Exit enrollment by turning the ignition off. The alarm confirms enrollment by
sending an SMS message to authorized phones TEL1 to TEL4.
If a detector is switched to delay mode, the alarm will provide a 20 second
entrance delay after the detector has been triggered. An exit delay of 20 seconds is
provided to all enrolled detectors after the car alarm has been armed.
If a sensor has been enrolled as an internal one, it can be re-enrolled as an
external one by its enrollment to the desired group.
If a group of detectors should be erased, take the same steps as with
enrollment, except that a “0“ should be added to the instruction (e.g. “LEARN
INT 0“). This starts enrollment and erases previously enrolled detectors. If no
new detectors should be enrolled, only turn the ignition off.
In the case of a low battery in any enrolled detector, an SMS report will be sent
to the first phone number stored in the car alarm’s memory.
Fig. 1: Wiring the alarm in RESET 1 mode. Wiring the alarm this way makes it possible to control the car’s central locking.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron CA-1802 - Athos GSM RESET 1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron CA-1802 - Athos GSM RESET 1 in the language / languages: English as an attachment in your email.

The manual is 0,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron CA-1802 - Athos GSM RESET 1

Jablotron CA-1802 - Athos GSM RESET 1 User Manual - English - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info