15
System
Local Setup
Each IDLV-4000P-xx has an IP address, a network sub mask and a gateway.
These parameters must be set to appropriate values so that the unit can be
accessed by the remote control system (for example: HDMS).
IP Address: The IP address for the unit.
Network Mask: The network mask for the subnet to which the unit is connected.
Gateway: The gateway for the network to which this unit is connected.
Trap IP
The IDLV-4000P provides a Monitor Center IP address. You can set this to be
the same IP address of the Monitor Center, which is typically a PC in order to
allow the device to send messages to the monitor center.
Unit Name
The IDLV-4000P allows you to edit the unit name which is displayed on the front
panel LCD. Default name is ‘Digital TV Processor”. The unit name should be
within 20 characters in ASCII format.
Properties
MAC address: Factory-set MAC address is guaranteed to be unique. You can-
not congure this address.
FW Version: the version of the FPGA software (note that this version number
will be changed automatically according to the TS/IP settings (‘IP In’ or ‘IP Out’).
SW Version: the version of the main software.
Factory
Settings
All the user congurable parameters will be set to the factory default settings,
including IP address and the unit name. Note the unit will not be connected with
the HDMS remote management system until the IP is properly congured.
O p t i o n a l
Function
External Board Type: Press the <ENTER>-key to activate the menu, and use
the <↑> <↓>-keys to congure the TS/IP functional block to ‘IP In’, ‘IP Out’ or ‘No
Exist’. Press the <ENTER>-key to conrm and save or press the <EXIT>-key to
discard and exit.
After the operation is complete, you need reboot the unit to valid the congura-
tion.
IP In: The TS/IP port is congured as input. You can feed transport stream over
IP into the unit. The menu ‘Ethernet’ will be shown under the inputs menu.
IP Out: The TS/IP port is congured as output. You can set the transport stream
over IP output to the IP network. The menu ‘Ethernet’ will be shown under the
outputs menu.
No Exist: The TS/IP port is invalid. Therefore, the menu ‘Ethernet’ will not be
shown anywhere.
Filter Function: Press the <ENTER>-key to activate the menu, and use the <↑>
<↓>-keys to enable MUX or Filter function. When enable this function, there will
be relative menu appearing in Output menu.
HTTP Login
Modify the username and password for the WEB management.
The default username: root
The default password: 12345
Machine Type
Reserved for factory operation, not open to customer.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inverto IDLV-4000P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inverto IDLV-4000P in the language / languages: English as an attachment in your email.

The manual is 2,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info