737431
36
Zoom out
Zoom in
Previous page
1/108
Next page
CONNECTING THE COOKER TO THE ELECTRICAL SYSTEM
The cooker is supplied without a connection cable and, in accordance with connection diagram A1, it is set
by default for 2 x 1 phase (230V). The cooker uses a so-called 5-pole Perilex plug (not included). In the meter
cupboard, the groups must each be protected with a 16 Ampere fuse at least.
The cooker can also be connected in accordance with connection diagram A2. This may only be performed
bya certified installer.
The socket for connecting to the electrical system must be provided with an earthing pen and may not be
located above the cooker. The socket for connecting to the electrical system must also be accessible for
theuser after placement of the cooker.
• Before connecting the cooker, check that:
- the fuse and electrical system are suitable for the load of the oven,
- the electrical system is equipped with an efficient earthing system that meets the current standards
andregulations.
- the socket is easily accessible.
ASSEMBLY OF THE TILTING SAFEGUARD
The tilting safeguard is mounted to prevent the cooker from tilting. Thanks to
the tilting safeguard, children are prevented from climbing on the open oven
door and tilting the cooker.
Cooker, 850 mm high
A = 60 mm
B = 103 mm
Cooker, 900 mm high
A = 104 mm
B = 147 mm
A
B
connection cableconnection blockconnection cableconnection block
A2
A1
36 English
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventum VFI5042RVS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventum VFI5042RVS in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 27,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Inventum VFI5042RVS

Inventum VFI5042RVS User Manual - English, German, Dutch, French - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info