771741
22
Zoom out
Zoom in
Previous page
1/140
Next page
Page 22
CAUTION
Ensure to wrap insulation around the piping.
Direct contact with the bare piping may result
in burns or frostbite.
Make sure the pipe is properly connected. Over
tightening may damage the bell mouth and
under tightening may lead to leakage.
CAUTION
Check to make sure there is no refrigerant leak
after completing the installation work. If there
is a refrigerant leak, ventilate the area immedi-
ately and evacuate the system (refer to the Air
Evacuation section of this manual).
6. Place flaring tool onto the form.
7. Turn the handle of the flaring tool clock-
wise until the pipe is fully flared. Flare the
pipe in accordance with the dimensions
shown in table 7.3.
8. Remove the flaring tool and flare form,
then inspect the end of the pipe for cracks
and even flaring.
Step 4: Connect pipes
Connect the copper pipes to the indoor unit
first, then connect it to the outdoor unit. You
should first connect the low-pressure pipe,
then the high-pressure pipe.
1. When connecting the flare nuts, apply a
thin coat of refrigeration oil to the flared
ends of the pipes.
2. Align the center of the two pipes that you
will connect.
6. After connecting the copper pipes to the in-
door unit, wrap the power cable, signal cable
and the piping together with binding tape.
7. Thread this pipeline through the wall and
connect it to the outdoor unit.
8. Insulate all the piping, including the valves
of the outdoor unit.
9. Open the stop valves of the outdoor unit
to start the flow of the refrigerant between
the indoor and outdoor unit.
3. Tighten the flare nut as tightly as possible
by hand.
4. Using a spanner, grip the nut on the unit
tubing.
5. While firmly gripping the nut, use a torque
wrench to tighten the flare nut according
to the torque values in table 7.5.
90°± 4
R0.4~0.8
45°± 2
Indoor unit tubing
min-radius 10cm (3.9”)
Bend the pipe with thumb
Flare nut Pipe
Table 7.3: PIPING EXTENSION BEYOND FLARE
FORM
Pipe
gauge
Tightening
torque
Flare dimension (A)
(Unit: mm/inch) Flare shape
Min. Max.
Ø 6.4 18-20 N.m
(183-204 kgf.cm) 8.4/0.33 8.7/0.34
Ø 9.5 25-26 N.m
(255-265 kgf.cm) 13.2/0.52 13.5/0.53
Ø 12.7 35-36 N.m
(357-367 kgf.cm) 16.2/0.64 16.5/0.65
Ø 15.9 45-47 N.m
(459-480 kgf.cm) 19.2/0.76 19.7/0.78
Ø 19.1 65-67 N.m
(663-683 kgf.cm) 23.2/0.91 23.7/0.93
Ø 22 75-85N.m
(765-867 kgf.cm) 26.4/1.04 26.9/1.06
Fig. 7.8
Fig. 7.9
Fig. 7.10
Fig. 7.11
NOTE: Use both a spanner and a torque
wrench when connecting or disconnecting
pipes to/from the unit.
NOTE: DO NOT intertwine signal cable with
other wires. While bundling these items to-
gether, do not intertwine or cross the signal
cable with any other wiring.
NOTE ON MINIMUM BEND RADIUS
Carefully bend the tubing in the middle ac-
cording to the diagram below. DO NOT bend
the tubing more than 90° or more than 3
times.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventor V6MKI32-WiFi at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventor V6MKI32-WiFi in the language / languages: English, German as an attachment in your email.

The manual is 22.17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Inventor V6MKI32-WiFi

Inventor V6MKI32-WiFi User Manual - English, German - 44 pages


The manual is sent by email. Check your email