SPA WATER CHEMISTRY AND BALANCE (continued)
SPA Water Adjustment
How to adjust the spa water chemistry when the levels are off the range. CAUTION: Always follow the
chemical manufacturer’s directions, and the health and hazard warnings.
Total Alkalinity (TA) Adjustment
Remove the spa cover to aerate the water and use the included test strips to check the chemistry level.
Ensure the chlorine level in the water is between 2-4 ppm rst, as chlorine will affect the TA test result.
If the TA level (and not the pH) is higher than 120 ppm, to lower the TA level, you add muriatic acid (hydrochloric
acid) or sodium bisulfate.
If the TA level is lower than 60 ppm, you add sodium bicarbonate.
For example (for 4 adults’), if the TA level is 180 ppm, the desired decrease is 60 ppm, from below chart, you
need to add 0.269 Lb (121 g) of sodium bisulfate or 0.101 qt (96 ml) of muriatic acid.
If the test strip color is between 180 ppm and 240 ppm, and close to 180 ppm, you can also add 0.269 Lb
(121 g) of sodium bisulfate or 0.101 qt (96 ml) of muriatic acid.
If the reading is more than 240 ppm, you can add sodium bisulfate or muriatic acid to the water drop by drop
until the test strip indicates a 240 ppm reading, then add 0.528 Lb (238 g) of sodium bisulfate or 0.202 qt
(192 ml) of muriatic acid.
NOTE: After adjustment, retest the water after 24 hours and adjust again if necessary.
Desired level 60 ppm 80 ppm 100 ppm 120 ppm 140 ppm
Volume:
210 gal / 795 L
0.269 Lb 0.358 Lb 0.448 Lb 0.528 Lb 0.627 Lb
121 g 161 g 202 g 238 g 283 g
Volume:
290 gal / 1098 L
0.368 Lb 0.492 Lb 0.614 Lb 0.737 Lb 0.860 Lb
168 g 224 g 279 g 335 g 391 g
Lowering Total Alkalinity
Amount of Sodium Bisulfate to lower Total Alkalinity
Desired level 20 ppm 40 ppm 60 ppm 80 ppm
Volume:
210 gal / 795 L
0.059 Lb 0.118 Lb 0.178 Lb 0.237 Lb
27 g 53 g 80 g 107 g
Volume:
290 gal / 1098 L
0.081 Lb 0.162 Lb 0.244 Lb 0.326 Lb
37 g 74 g 111 g 148 g
Raising Total Alkalinity
Amount of Sodium Bicarbonate to raise Total Alkalinity
Desired level 60 ppm 80 ppm 100 ppm 120 ppm 140 ppm
Volume:
210 gal / 795 L
0.101 qt 0.135 qt 0.169 qt 0.202 qt 0.234 qt
96 mL 128 mL 160 mL 192 mL 223 mL
Volume:
290 gal / 1098 L
0.139 qt 0.185 qt 0.232 qt 0.278 qt 0.324 qt
132 mL 176 mL 220 mL 264 mL 308 mL
Amount of Muriatic Acid to lower Total Alkalinity
(Muriatic acid: 31.45%)
pH Adjustment
After the total alkalinity has been lowered to 120 ppm or raised to 80 ppm and the pH is still high or low, you
can adjust it using the following chart.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex SSP-H-10 PureSpa at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex SSP-H-10 PureSpa in the language / languages: English as an attachment in your email.

The manual is 3.12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info