SAVE THESE INSTRUCTIONS Page 5
(114) ELECTRIC POOL HEATER ENGLISH 7.5” X 10.5” PANTONE 295U 12/18/2006
SSEETT--UUPP IINNSSTTRRUUCCTTIIOONNSS
SET UP INSTRUCTIONS
IMPORTANT: The electrical pool heater must be installed as the last piece
of pool equipment before the saltwater pool or chlorine generator system in
the water return line to the pool
1. Assemble the above-ground-pool (AGP) and its filter pump per
installation instructions.
2. Remove the electrical pool heater and it’s accessories from the
packaging.
3. Place the electrical pool heater in line after the filter pump.
4. Connect the hose (1) to the electrical pool heater inlet. (See following
page)
5. If your above-ground-pool is filled up with water, unscrew the strainer
grids from the strainer connectors and insert the black hat-like plugs into
the strainer connectors before electrical pool heater installation. Go to
step 6 directly if your pool is empty.
6. Disconnect the water return (to the pool) hose from the filter pump
connection, and connect it to the upper electric pool heater connection
with a hose clamp.
7. Connect the second hose to the lower electric pool heater connection
and to the lower pump connection. Make sure all the hose clamps (2)
are tight.
8. If applicable, return strainer grids to strainer connectors inside pool after
removing black hat-like plugs that prevented water from flowing out of
the pool.
9. Connect the electric pool heater to the power outlet. Test RCD as
shown on following page.
10. Turn pump on. Check water is flowing through the heater. Then turn
heater on.
IMPORTANT
If the heater is not in an upright position a safety switch will
automatically turn the heater off. Be sure the heater is always in an
upright position while the cord is connected to the power outlet.