6.5 Programming the analog outputs
Select one of the Analog output tabs. The Analog output page looks like this:
This shows the analog output voltages versus Lambda for one of the two analog outputs. The
graph display is automatically scaled to the selected voltages. For each output you can specify a
minimum and maximum lambda value and the associated voltages. Below the minimum and
above the maximum lambda values the output voltages stay constant at the associated
programmed voltage.
By selecting the ‘use Air-Fuel-Ratio’ button you can program the curve by AFR instead of
Lambda. This does not change the programming, only the representation of the data.
When programming by AFR the LM Programmer converts the number to Lambda before
programming the LC-1.
Click the Program button to download the new data into the LC-1.
As factory programmed the first output simulates a typical narrow band oxygen sensor. The
second output is programmed to output between 0 V for an AFR of 7.35 (gasoline) and 5.0V for
an AFR of 22.39. Other curves of course are easily programmable
6.5.1 Advanced output programming
The normal state of the analog outputs is to update the outputs every time the LC-1 takes a new
measurement. The LC-1 is fast enough to distinguish individual pockets of exhaust gas. For
many applications this will be too fast. The advanced programming allows to set the analog out
update speed.
Press the “Advanced button” to set the advanced analog out settings. The following dialog box
will appear:
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Innovate LC-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Innovate LC-1 in the language / languages: English as an attachment in your email.

The manual is 0,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info