Suggestions for power saving
Diagnosis of problems
- Always keep the filters clean (see maintenance and
cleaning chapter).
- Keep the doors and windows of the rooms to be air
conditioned closed
Do not let direct sunlight to enter the room (use
curtains or lower the blinds or close the shutters)
- Do not block the air flow paths (input and output)
of the unit; this, as well as causing a non-optimal
performance of the unit, will jeopardise the correct
operation of the same and may cause irreparable
damage to the units.
For the User it is very important to distinguish any
inconveniences or abnormal operation of the unit
compared to its normal operation. Also, the most
common problems can be easily solved by means of
simple operations performed by the User (See paragraph:
Troubleshooting), while for some alarms signalled on the
display, it is necessary to contact Customer Service.
We also remind you that any attempt to repair the unit on part
of unauthorised technicians will void the warranty immediately.
- The compressor will not restart before a certain time has
passed (about three minutes from the previous stop). It is
not possible to stop and restart the compressor without
waiting at least three minutes. This is provided for in the
operating logic of the unit, so as to protect the compressor
from frequent activations.
- During operation in heating mode, the warm air is delivered
a few minutes after the activation of the compressor. If the
fan started at the same time as the compressor, in the first
minutes of operation the air delivered would be too cold
(which may disturb the occupants of the room) since the
unit is not yet ready.
If the remote control has been lost, the batteries are exhausted or it
no longer works, the unit can be operated by using the keys on the
touch screen display on the machine.
Operating aspects that should not be interpreted as problems
Season change procedure
Using the unit if the remote control is not available
Should any anomaly occur in the condensation water
system, the maximum level float blocks the conditioner
and the OF code appears on the display.
During cooling and dehumidification, electronics keeps the
water distribution system active with the battery - together
with the fan - to disperse excess water in the container.
If the problem persists, please contact the assistance
service.
During heating, condensation should drain freely through
the specific pipe. In the event of an alarm, check that
the condensation pipe is not bent or obstructed, thus
preventing the water from flowing out.
Note: At the end of the summer season empty the residual
condensation by opening the cap of the condensation
drainage pipe.
Evacuation of condensate water in the event of an emergency
If the presence contact is not closed, the appliance will
not start and the CP alarm appears on the display.
Open CP contact
Note: When installing the nebulizer 3.0 it's very important
to follow the indicated procedure to avoid a systematic
alarm and the possible failure of the nebulizer.
This procedure, enabled through the display of the air
conditioner ..2.0, modifies the default settings of the drain
pan of the appliance by disabling its automatic closure
during the summer season. This procedure is used to
avoid that during the summer season, with the opening
of the drain valve of the drain pan, the condensate itself
is poured all in the 3.0 nebulizer installed under the
appliance.
To activate this function:
- Press the cooling mode key on the display of the ..2.0
for 15 sec.
- The symbol “En” will appear
- Press again for 15 sec. the key
- The symbol “ds” will apppear
- Let the display go back to the main screen
The condensate drain will always remain open in both
seasons, guaranteeing a regular flow of condensation.
Configuration with the nebulizer 3.0
9


Need help? Post your question in this forum.

Forumrules
1

Forum

innova-2.0

Reset search

  • i need a simple instruction on hoe to operate the remote control for the innova2.0vertical 10-12DC Inverter A/C unit this is for a nursing home where the residents need the simple example please help i checked the operators manual and its to much for them to comprehend thanks Submitted on 15-7-2022 at 15:49

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Innova 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Innova 2.0 in the language / languages: English as an attachment in your email.

The manual is 6,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Innova 2.0

Innova 2.0 Installation Guide - English - 20 pages

Innova 2.0 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info