INSTALLATION
The appliance is equipped with a power cord and plug
(Y-type connection, the cord can only be replaced by the
manufacturer, the assistance centre or a qualified installer).
If using a socket near the appliance, simply insert the plug.
Before connecting the conditioner check that:
- The power supply voltage and frequency values
comply with the data plate of the appliance.
- The power supply line has a suitable earth connection
and that it is sized for the maximum absorption of
the conditioner (minimum cable section equal to 1.5
mm
2
).
- Power is only supplied using a suitable socket through
the supplied plug.
If the supply cable is replaced, this must be done
exclusively by the technical assistance service or by
authorised personnel and in compliance with current
national regulations.
The appliance must be connected to 230V/50 Hz
mains via an omnipolar switch with a contact opening
distance of minimum 3 mm, or using a device
enabling the complete disconnection of the appliance
in overvoltage III category conditions.
It is possible to carry out the electrical connection using
a cable inside of the wall as indicated in the installation
template (recommended for installations in the upper part
of the wall).
Please check that the power supply is provided with
suitable protections against overloads and/or short-circuits
(using a 10 Amp Time delay fuse or other equivalent
devices is recommended).
To prevent any risk of electrocution, always disconnect the
main circuit breaker before making electric connections or
performing any maintenance on the units.
To carry out direct connections and substitute the power
cord using the cable in the wall, proceed as follows:
- Remove the upper grill.
- Remove the two plastic side panels, by lifting them
upwards.
- Undo the front panel fixing screws.
- Remove the front panel.
- Disconnect the power cord by unscrewing the 3
screws from the terminal block.
- Connect the wall cable, checking that the power
supply line has a suitable earth connection and that it
is sized for the maximum absorption of the conditioner
(minimum cable section equal to 1.5 mm
2
).
Electrical connection
Bracket
Bracket anchoring points
Anti-lifting bracket
After checking that the bracket is anchored to the wall and
that all necessary electrical connections and condensation
drain preparations have been made, you can mount the
conditioner. Lift it by the sides of the bottom base until
the bracket fits on all of the right spots on the appliance.
In order to ease the operation, slightly tilt the appliance
towards you.
Direct electrical connections (disconnecting the power
supply cable) and the anchoring of the condensation drain
must be carried out after having spaced the appliance
from the wall using a wooden wedge or any other similar
object.
Once the work is done, check that there are no openings
on the back of the appliance, especially where the air
ducts are connected. To improve installation safety, the
machine can be secured to the wall with a dedicated anti-
lifting bracket
which is located on the rear part of the machine. The
drilling position is indicated on the installation template.
Mounting the appliance on the bracket
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Innova 2.0 verticale at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Innova 2.0 verticale in the language / languages: English as an attachment in your email.

The manual is 3,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info