Before leaving the work area, a tightness check must be carried out.
9. DECOMMISSIONING OF THE REFRIGERANT
Before performing this procedure, it is essential that the technician is familiar with
the equipment and all its details. It is good practice to recommend that all refrigerants
are safely recovered. Before carrying out the work, you need to pick up a sample of oil
and refrigerant in case analysis is required before reusing the regenerated refrigerant.
It is essential that electricity is available before the start of the activity.
a) Become familiar with the equipment and its operation.
b) Isolate the system electrically.
c) Before attempting the procedure, make sure that: mechanical handling equipment
is available, if necessary, for handling the refrigerant cylinders; all personal protective
equipment is available and used correctly; the recovery process is supervised at
all times by a competent person; recovery equipment and cylinders conform to
appropriate standards.
d) Depressurize the refrigerant system, if possible
e) If a vacuum is not possible, make a manifold so that the refrigerant can be removed
from various parts of the system.
f) Make sure the cylinder is on the scale before recovery takes place.
g) Start the recovery machine and operate according to the manufacturer’s instructions.
h) Do not overfill the cylinders. (Not more than 80% volumetric liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
j) When the cylinders have been filled correctly and the process has been completed,
make sure that the cylinders and equipment have been removed from the site
immediately and that all isolation valves on the equipment have been closed.
k) The recovered refrigerant must not be charged to another refrigeration system
unless it has been cleaned and checked.
10. LABELING
The equipment must be labeled stating that it has been taken out of service and
GB
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Innoliving INN-520 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Innoliving INN-520 in the language / languages: English, Italian as an attachment in your email.

The manual is 2.8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info