WIREMAP TEST SCREEN
If more detail is required about the Wiremap Test, the Wiremap screen can be displayed by
highlighting the Wiremap Test icon on the HOME screen and pressing Enter.
Summary
Shows the status or result of the test. In this example, pins 1 and 2 are reversed, resulting in a
miswire fault. Ethernet is tolerant of such a fault, so the Data Test will pass in this case. That is why
it is important to perform both the data test and the wiremap test to prove that the cable meets all
of the required quality standards.
Test Status:
Ready to test
Test in progress
Test Passed
Test Failed
Shows the length of each pair (some
pairs may be longer than the overall
cable due to the cable construction)
Cable Type
Shows cable type selected in
SETUP
Remote Unit pin numbers
Test Unit pin numbers
Shows the overall cable length
Press F3 (SETUP) to adjust the
test settings
Press F1 (RUN) to run the
Wiremap test for
troubleshooting (result can not
be saved)
Press F2 (FAULT) to view the fault details
A split pair is a wiring error in which each pin is connected to the correct pin at the other end of the cable, but
the pairs of pins are connected using wires from different twisted pairs. Split pairs can cause crosstalk and
data failures, but are not reported as faults by simple wiremappers. The advanced wiremapper in SignalTEK
CT can detect split pairs that some other wiremappers can not detect. Split pairs can start with a simple wiring
error. In the example below, pins 3 and 4 are reversed at one end of the cable:
5
4
3
6
5
4
3
6
5
4
3
6
5
4
3
6
5
4
3
6
5
4
3
6
If the error is repaired at end of the cable where the fault is located, the fault is removed:
If the error is repaired at the wrong end of the cable, the end-to-end continuity is corrected,
but a split pair is formed:
This cable may cause Ethernet data errors, and if so it will fail the SignalTEK CT Data Test.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ideal Networks SignalTEK CT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ideal Networks SignalTEK CT in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 2,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info