7 SignalTEK CT 156840.02
DATA TEST SCREEN
If more detail is required about the Data Test, the Data screen can be displayed by highlighting the
Data Test icon on the HOME screen and pressing Enter.
Summary
Shows the status of the test
Duration
Shows the duration of the test. In order
to comply with the Ethernet standard
at 1Gb/s, the data test must be run for
10 seconds
Test Status:
Ready to test
Test in progress
Test Passed
Test Failed
Notifications Area
Shows details of the test
status
Frames Sent
Shows the number of Ethernet
frames sent over the cable. In
order for the cable to comply
with the Ethernet standard at
1Gb/s, 823,452 frames
(containing 10
10
bits) must be
sent and received error free
Frames Received
Shows the number of Ethernet
frames received error free
Frame Errors
Shows the number of errored
Ethernet frames received. One or
more errors will cause the cable to
fail the Ethernet standard
Press F2( FAULT) to display possible fault
causes
Possible causes of data test failures include:
Excessive cable length. The maximum length allowed by the Ethernet standard for 1Gb/s is
100 metres. Cables longer than this may still operate error free, but may be unreliable. Even
cables shorter than this may produce data errors and fail the data test if they have other
faults. If the Data Test fails, check the length of the cable ( shown in the HOME screen and in
the Wiremap result). If the cable exceeds 100 metres in length, it is recommended to replace
it with a shorter one.
Bad twisting. For optimum performance it is important that the twisting of the individual pairs
is carried right up to the termination, to avoid crosstalk which can affect data performance.
Bad twisting does not show up as a wiremap fault. If the data test fails, it is recommended to
inspect the terminations and re-terminate if the twisting is sub-standard.
Poor cable quality. Some brands of cable can give inferior data performance and cause
data errors, especially on longer lengths. If the data test fails, but the wiremap test passes,
and the length is approaching 100 metres, it is recommended to check the cable quality
Split pairs. Split pairs can cause data errors or complete failure of the cable to carry Ethernet
traffic. Cables that are a composite of a long length with no split pairs, connected to a shorter
length with split pairs, may not show up as a wiremap fault but can cause data errors and fail
the data test.
Data errors can occur even if the wiremap shows that the cable is correctly terminated. That is why it
is important to perform both the data test and the wiremap test to prove that the cable meets all of
the required quality standards.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ideal Networks SignalTEK CT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ideal Networks SignalTEK CT in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 2,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info