615948
75
Zoom out
Zoom in
Previous page
1/110
Next page
Chapter 8
Fiber testing (LWL) FiberTEK™ FDX
74
8.4. Test Setup According to Reference Method with Three Test Cords
(based on ISO/IEC 14763-3)
This is the preferred measuring method, which can be used for any topology - both
installation and transmission line. Irrespective of the plug face, it is also used on the
measuring equipment and within the transmission line.
Calibration takes place via reference line between the launch cords and tail cords used for
measurement.
This measurement method is applied to FiberTEK™ FDX.
Illustration 8.4. Test Setup According to Reference Method with
Three Test Cords
8.5. Test setup According to Reference Method with One Test Cord
(based on ISO/IEC 14763-3)
This measuring method is only permitted for measurement of installation lines that are set up
as Simplex lines. Furthermore, all connectors on the measuring equipment and within the line
must be of the same type.
Calibration is performed with the launch cord used for the measurement. Subsequently, the
line to be measured and a tail cord are introduced.
Illustration 8.5. Test Setup According to Reference Method with One
Test Cord
75


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ideal Networks LanTEK III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ideal Networks LanTEK III in the language / languages: English as an attachment in your email.

The manual is 3,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info