615947
9
Zoom out
Zoom in
Previous page
1/25
Next page
FiberTEK III Document 164802 Iss 3
User Manual Page 9
Standards
Organization
Classification or
Application
Fiber Type
Core size (um) /
wavelength (nm)
Max Link Channel
Loss (dB)
Max Connector
Insertion Loss (dB)
Max Splice
Insertion Loss (dB)
Min Connector
Return Loss (dB)
Maximum Distance
(m)
Min Operating
Distance (m)
(50um/62.5um)
Max Fiber
Attenuation
(dB/km)
Min Fiber
Bandwidth (MHz-
km)
OF-500 OM2
50 or
62.5/850
3.25
0.75 ea/
1.5 total
0.3
>20 n/s 500 3.5 500
OF-500 OM2
50 or
62.5/1300
2.25
0.75 ea/
1.5 total
0.3
>20 n/s 500 3.5 500
OF-500 OM3 50/850
3.25
0.75 ea/
1.5 total
0.3
>20 n/s 500 3.5 1500
OF-500 OM3 50/130
2.25
0.75 ea/
1.5 total
0.3
>20 n/s 500 1.5 500
OF-500 OS1
9/1310 or
1550
2.00
0.75 ea/
1.5 total
0.3
>35 n/s 500 1.0 n/a
OF-2000 OM1
50 or
62.5/850
8.50
0.75 ea/
1.5 total
0.3
>20 n/s 2km 3.5 200
OF-2000 OM1
50 or
62.5/1300
4.50
0.75 ea/
1.5 total
0.3
>20 n/s 2km 1.5 500
OF-2000 OM2
50 or
62.5/850
8.50
0.75 ea/
1.5 total
0.3
>20 n/s 2km 3.5 500
OF-2000 OM2
50 or
62.5/1300
4.50
0.75 ea/
1.5 total
0.3
>20 n/s 2km 1.5 500
OF-2000 OM3 50/850
8.50
0.75 ea/
1.5 total
0.3
>20 n/s 2km 3.5 1500
OF-2000 OM3 50/130
4.50
0.75 ea/
1.5 total
0.3
>20 n/s 2km 1.5 500
OF-2000 OS1
9/1310 or
1550
3.50
0.75 ea/
1.5 total
0.3
>35 n/s 2km 1.0 n/a
IEEE 802.3 10Base-FL
Multimode/
OM1-OM2
62.5/850
12.50
0.75 ea/
1.5 total
n/s
>20 2km 0 3.75 160
10Base-FL
Multimode/
OM1-OM3
50/850
12.50
0.75 ea/
1.5 total
n/s
>20 1.5km 0 3.75 160
100Base-FX
Multimode/
OM1-OM3
62.5 or
50/1300
11.00
0.75 ea/
1.5 total
n/s
n/s 2km 0 3.75 500
1000Base-SX
Multimode/
OM1-OM2
62.5/850
2.33
0.75 ea/
1.5 total
n/s
>20 n/s 220 3.75 160
1000Base-SX
Multimode/
OM2-OM3
62.5/850
2.53
0.75 ea/
1.5 total
n/s
>20 n/s 275 3.75 200
1000Base-SX
Multimode/
OM1-OM3
50/850
3.25
0.75 ea/
1.5 total
n/s
>20 n/s 500 3.5 400
1000Base-SX
Multimode/
OM2-OM3
50/850
3.43
0.75 ea/
1.5 total
n/s
>20 n/s 550 3.5 500
1000Base-LX
Multimode/
OM1-OM2
62.5/1300
2.32
0.75 ea/
1.5 total
n/s
>20 n/s 550 1.5 500
1000Base-LX
Multimode/
OM1-OM2
50/1300
2.32
0.75 ea/
1.5 total
n/s
>20 n/s 550 1.5 400/500
1000Base-LX
Singlemode/
OS1
9/1310
4.50
0.75 ea/
1.5 total
n/s
>26 n/s 5km 0.5 n/a
10GBase-SR
Multimode-
OM1
62.5/850
2.60
0.75 ea/
1.5 total
n/s
>20 n/s 26 3.5 160
10GBase-SR
Multimode-
OM1
62.5/805
2.50
0.75 ea/
1.5 total
n/s
>20 n/s 33 3.5 200
10GBase-SR
Multimode/
OM2-OM3
50/850
2.20
0.75 ea/
1.5 total
n/s
>20 n/s 66 3.5 400
ISO 11801
Generic
Cabling
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ideal Networks FiberTEK III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ideal Networks FiberTEK III in the language / languages: English as an attachment in your email.

The manual is 0,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info