5-3
5
RECEIVE FUNCTIONS
DD
Fixed frequency mode
Displays signals within the specified frequency range.
The selected frequency band conditions can be ob-
served at a glance when using this mode.
q Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w Push [F-1•SCOPE] to select the scope screen.
The spectrum scope shows the peak level holding func-
tion. Peak levels are displayed in the background of the
current spectrum in a different color until the receive fre-
quency changes. This can be deactivated and the
waveform color can be set in scope set mode. (p. 5-7)
e Push [F-6•CENT/FIX] to select the fixed mode.
•“ ” is displayed when fix mode is selected.
r Push [F-2•EDGE] once.
Multifunction switch guide changes to the resolution
band width/speed setting guide.
t Push [START] then edit the desired frequency using
the keypad to set the lower frequency edge, and
push [STOP] then edit the desired frequency using
the keypad to set the higher frequency edge.
y Push [F-3•BW/SPEED] once.
Multifunction switch guide changes to the resolution
band width/speed setting guide.
u Push [BW+] or [BW–] several times to select the
resolution band width.
0.2 k, 0.5 k, 1 k, 2 k, 5 k, 10 k and 20 kHz are available
depends on the frequency range.
i Push [SPEED–] or [SPEED+] several times to se-
lect the sweeping speed.
o Push [F-4•ATT] several times to activate an attenu-
ator or turn the attenuator OFF.
10, 20 and 30 dB attenuators are available.
!0 Push [F-5•HOLD] to freeze the current spectrum
waveform.
•“ ” appears while the function is in use.
The peak hold function can be deactivated in scope set
mode.
!1 Push [EXIT/SET] to exit the scope screen.
NOTE: If a strong signal is received, a ghost wave-
form may appear. Push [F-4•ATT] several times to
activate the spectrum scope attenuator in this case.
HOLD
FIX
[F-5][F-3][F-2][F-1] [F-6][F-4] [F-7]
EDGE
BW/SPEED
CENT/FIX
PEAK
SET
MENU1
ATT HOLD
W-BPFMENU2
[EXIT/SET][F-5][F-3]
[F-2]
[F-1]
Multifunction switch
[F-6]
69


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-R9500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-R9500 in the language / languages: English as an attachment in your email.

The manual is 21,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info