458649
81
Zoom out
Zoom in
Previous page
1/108
Next page
68
12
CONTROL COMMAND
11
12
General
The IC-R20 can be connected to a PC via the PC’s RS-232C
port using an optional CT-17
CI-V LEVEL CONVERTOR
. This
allows you to control the receiver from the PC and/or transfer
data from the receiver to the PC.
Control is provided via Icom’s CI-V Communication Interface.
An appropriate application for CI-V command is not sup-
plied from Icom.
Data format
The CI-V system can be operated using the following data
formats. Data formats differ according to command numbers.
A data area is added for some commands.
Controller IC-R20
IC-R20 Controller
q Preamble code (xed)
w Receiver’s default address
e Controller’s default address
r Command number (see table below)
t Sub command number (see table below)
y BCD code data for frequency entry
u End of message code (xed)
Command table
FE FE 6C E0 Cn Sc Data area FD
q wert y u
FE
FE E0 6C Cn Sc Data area FD
q ewrt y u
Description Cn Sc
Transfers frequency data (transceive) 00
Transfers mode data (transceive) 01
Reads display frequency 03
Reads display mode 04
Sets frequency data 05
Sets LSB mode
06
00
Sets USB mode 01
Sets AM mode 02
Sets CW mode 03
Sets FM mode 05
Sets WFM mode
06
Reads squelch condition (open or closed)
15
01
Reads S-meter level
02
81


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-R20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-R20 in the language / languages: English as an attachment in your email.

The manual is 2,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info