TROUBLESHOOTING
16
17
PROBLEM POSSIBLE CAUSE SOLUTION REF.
If your receiver seems to be malfunctioning, please check the following points before sending it to a service center.
Does not turn on.
No sound comes from the
speaker.
Sensitivity is low and only
strong signals are audible.
Frequency cannot be set
via the PC key board.
Program scan does not
operate.
Memory scan does not op-
erate.
The Communication error
occurs after launching the
IC-PCR1500_2500 pro-
gram.
The AC adapter is not fully seated in the power
jack on the Main unit’s rear panel.
An AC adapter is connected to the same AC outlet
with a PC, printer, etc.
•Volume is too low.
• The audio mute function is activated.
• Squelch is set too high.
Band scope function is activated in SSB or CW
mode.
Antenna feedline or the antenna connector has a
poor contact or is short circuited.
• Squelch attenuator function is activated.
The receiver screen is not selected.
• The squelch is open.
• The start and end frequencies are the same.
• The squelch is open.
Only 1 memory channel is programmed or other
channels are set as skip channel.
The computer does not recognize the connected
Main unit.
The protector circuit of the power supply is acti-
vated.
• Check the connection.
Check the connection.
• Right click [AF GAIN].
• Push [MUTE] to turn the mute function OFF.
• Set the squelch level to the threshold.
Pause or cancel the band scope function in SSB or
CW mode.
Check, and if necessary, replace the feedline or sol-
der the antenna connector again.
• Push [ATT] to turn the Attenuator function OFF.
•Click anywhere in the receiver screen first, then
input the frequency.
• Set the squelch to the threshold point.
• Set the different frequencies.
• Set the squelch to the threshold point.
Program other memory channels or cancel the
memory skip function in the desired channels.
Launch the program after approx. 20 sec. has
passed.
• Use the supplied AC adapter, or a stabilized power
supply with large capacity.
p. 1
p. 1
p. 52
p. 56
p. 53
p. 98
p. 1
p. 59
p. 48
p. 53
p. 71
p. 53
pgs. 70,
86
p. 27
pgs. 1,
2
143


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-PCR1500 IC-PCR2500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-PCR1500 IC-PCR2500 in the language / languages: English as an attachment in your email.

The manual is 9,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info