BAND SCOPE
Operation
The band scope function allows you to visually check a spec-
ied frequency range.
Receive audio is muted while monitoring the band scope.
Push [s/❙❙] to pause sweeping and receive the audio.
D Using the multi-function receiver screen
q Click the sweep start/pause button ([s/❙❙]) to begin a
sweep; signal conditions appear starting from the center of
the range.
Conditions over the entire set frequency span can be observed
around the center frequency of the currently received frequency.
w Click the [SPAN+] or [SPAN] button to select the sweep
width through SPAN1 (±100 kHz) to SPAN4 (±2 MHz).
e Click the [TSJ] or [TSK] button to select the sweep tuning
step.
•“LIMITappears when a tuning step greater than the sweep step
range is selected.
r Click the waveform to select the frequency of the signal.
Click the [s/❙❙] button to pause a sweep and monitor the fre-
quency. Repeat to resume the sweep.
While pausing the band scope, you can also select the frequency
by clicking the waveform. The current receive frequency is
marked by a dotted line and the previous receive frequency is
displayed at center.
t Click the sweep stop button ([]) to cancel a sweep.
D Using the simple function receiver screen
q Call up the band scope screen if it is not displayed.
Click the [MENU] button and select the Band Scope.
w Click the sweep start/pause button ([s/❙❙]) to begin a
sweep; signal conditions appear starting from the center of
the range.
Conditions over the entire set frequency span can be observed
around the center frequency of the currently received frequency.
e Click the [] or [] button to select the sweep width
through SPAN1 (±100 kHz) to SPAN4 (±2 MHz).
Choose [SPAN1] when band conditions are crowded (many sig-
nals are present); choose [SPAN4] when few signals are present.
r Click the [TSJ] or [TSK] button on the function controller
screen to select the sweep tuning step.
Click [MENU] and select the Function controllerwhen it is not
displayed.
•“LIMITappears when a tuning step greater than the sweep step
range is selected.
Click to select sweep width.
Click to start or pause sweeping.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-PCR100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-PCR100 in the language / languages: English as an attachment in your email.

The manual is 0,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info