PROBLEM POSSIBLE CAUSE SOLUTION REF.
SPEECH
11
76
MAINTENANCE
Troubleshooting
The following chart is designed to help you correct
problems which are not equipment malfunctions.
If you are unable to locate the cause of a problem or
solve it through the use of this chart, contact your near-
est Icom Dealer or Service Center.
Power does not come on
when [POWER] is pushed.
No sounds comes from
the speaker.
Sensitivity is low.
Received audio is dis-
torted.
Transmitting is impossible.
Output power is too low.
No contact possible with
another station.
Transmitted signals are
distorted.
Repeater cannot be ac-
cessed.
Programmed scan does
not start.
Memory scan does not
start.
Mode select scan does not
start.
No announcement when
[SPCH] is pushed.
The displayed frequency
does not change properly.
DC power cable is improperly connected.
Fuse is blown.
Volume level is too low.
The squelch is closed.
The transceiver is in the transmitting condition.
The antenna is not connected properly.
The attenuator is activated.
The S-meter squelch is activated.
Incorrect sideband (USB/LSB) is selected.
Receiving an FM signal.
Noise blanker is activated.
Noise reduction is activated.
PTT lock function is activated.
[RF PWR] is set too far counterclockwise.
[MIC GAIN] is set too far counterclockwise.
Split frequency operation or duplex operation is
activated.
RIT function is activated.
[MIC GAIN] to far clockwise.
Duplex operation is not activated.
No subaudible tone or incorrect tone frequency
is selected.
VFO mode is not selected.
[RF/SQL] is assigned to RF gain and squelch is
opened.
Memory mode is not selected.
No memory channels are programmed.
Mode select scan mode has not been selected.
Only one channel is programmed with the se-
lected operating mode.
The voice synthesizer unit has not been in-
stalled.
The announcement level is set to 0 or too low.
The announcement language is set to oFF.
The dial lock function is activated.
The internal CPU has malfunctioned.
Reconnect the DC power cable correctly.
Check the cause, then replace the fuse with a
spare one. (Fuses are installed in the DC power
cable and the internal PA unit.)
Rotate [AF] clockwise to obtain a suitable listen-
ing level.
Rotate [RF/SQL] to 12 oclock position to open
the squelch.
Push [TRANSMIT] to receive or check the SEND
line of an external unit, if desired.
Reconnect to the antenna connector.
Push [ATT] to turn the attenuator OFF.
Rotate [RF/SQL] to the position where the noise
just disappears.
Switch USB and LSB by pushing [SSB/CW] for
1 sec.
Push [FM] to select FM mode.
Push [AFC/NB] to turn the noise blanker function
OFF.
Set the noise reduction level in the NR set mode
for maximum readability using [SET] and
[AFC/NBNR], or turn OFF the function by push-
ing [AFC/NBNR] for 1 sec.
Turn the PTT lock function OFF in the TRANSMIT
set mode using [SET] and [TRANSMIT].
Rotate [RF PWR] clockwise.
Rotate [MIC GAIN] clockwise.
Push [SPLIT] momentarily or for 1 sec. to turn the
split or duplex function OFF.
Push [RIT] to turn the RIT function OFF.
Set [MIC GAIN] to a suitable level.
Push [SPLITDUP] for 1 sec. to turn duplex oper-
ation ON.
Push [TONE] to activate the subaudible tone or
select a suitable tone frequency in the FM set
mode using [SET] and [FM].
Push [V/M 1] to select VFO mode.
Reset [RF/SQL] control assignment and set it to
the threshold point.
Push [V/M 1] to select memory mode.
Program desired frequencies into memory chan-
nels.
Push [SPCHLOCK] for 1 sec. on the desired op-
erating mode programmed channel.
Program more than two channels with the desired
operating mode.
Install the optional vice synthesizer unit, UT-102.
Set the announcement level to a suitable level in
the SPCH set mode using [SET] and [SPCH].
Set the announcement language to Eng (or JPn)
in the SPCH set mode using [SET] and [SPCH].
Push [SPCHLOCK] to turn the lock function OFF.
Reset the CPU.
p. 77
p. 26
p. 26
pgs.
2, 13
p. 29
p. 26
p. 23
p. 23
p. 30
p. 31
p. 66
p. 32
p. 32
p. 37
p. 27
p. 32
p. 34
p. 35
p. 21
p. 26
p. 40
p. 41
p. 47
p. 41
p. 71
p. 69
p. 69
p. 25
p. 77
78


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-910H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-910H in the language / languages: English as an attachment in your email.

The manual is 2,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info