12296
6
Zoom out
Zoom in
Previous page
1/88
Next page
INSTRUCTION MANUAL
iC- 2710h
DUAL BAND FM TRANSCEIVER
IC-2710H.qxd 02.2.8 16:55 Page A (1,1)
RWARNING! NEVER connect the transceiver to an
AC outlet. This may pose a fire hazard or result in an electric
shock.
RWARNING! NEVER operate the transceiver while
driving a vehicle. Safe driving requires your full attention—
anything less may result in an accident.
NEVER connect the transceiver to a power source of more
than 16 V DC. This connection will ruin the transceiver.
NEVER connect the transceiver to a power source using
reverse polarity. This connection will ruin the transceiver.
NEVER cut the DC power cable between the DC plug and
fuse holder. If an incorrect connection is made after cutting,
the transceiver might be damaged.
NEVER place the transceiver where normal operation of
the vehicle may be hindered or where it could cause bodily
injury.
NEVER let objects impede the operation of the cooling fan
on the rear panel.
DO NOT push the PTT when not actually desiring to transmit.
i
IMPORTANT
READ ALL INSTRUCTIONS carefully and completely before
using the transceiver.
SAVE THIS INSTRUCTION MANUAL—This instruction man-
ual contains important operating instructions for the
IC-2710H.
EXPLICIT DEFINITIONS
The explicit definitions below apply to this instruction manual.
CAUTIONS
WORD DEFINITION
RWARNING
Personal injury, fire hazard or electric shock
may occur.
CAUTION
Equipment damage may occur.
NOTE
If disregarded, inconvenience only. No risk
of personal injury, fire or electric shock.
The IC-2710H Europe versions comply with essential re-
quirements of the 89/336/EEC directive for Electromagnetic
Compatibility. This compliance is based on conformity with
the ETSI specification prEIS300 684 (EMC product standard
for Commercially Available Amateur Radio Equipment).
IC-2710H.qxd 02.2.8 16:55 Page i (1,1)
ii
UNPACKING
Accessories included with the transceiver:
Qty.
DC power cable (OPC-346)............................................. 1
Mobile mounting bracket ................................................. 1
Microphone (HM-98)........................................................ 1
Fuse (20 A)...................................................................... 1
Knob bolt (M4 x 8) ........................................................... 4
Mounting bolt (M5 x 12)................................................... 4
Nut (M5)........................................................................... 4
Spring washer (M5) ......................................................... 4
Flat washer (M5).............................................................. 4
Self-tapping screws (A0 5 x 16)....................................... 4
DO NOT allow children to play with any radio equipment
containing a transmitter.
During mobile operation,
DO NOT operate the transceiver
without running the vehicle’s engine. When transceiver power
is ON and your vehicle’s engine is OFF, the vehicle’s battery
will soon become exhausted.
BE CAREFUL! The transceiver will become hot when
operating it continuously for long periods.
AVOID using or placing the transceiver in areas with tem-
peratures below –10°C (+14°F) or above +60°C (+140°F) or
in areas subject to direct sunlight, such as the dashboard.
AVOID the use of chemical agents such as benzine or al-
cohol when cleaning, as they can damage the transceiver
surfaces.
USE Icom microphones only (supplied or optional). Other
manufacturer’s microphones have different pin assignments
and may damage the transceiver.
➀➁
IC-2710H.qxd 02.2.8 16:55 Page ii (1,1)
TABLE OF CONTENTS
iii
IMPORTANT .................................................................................... i
EXPLICIT DEFINITIONS ................................................................. i
CAUTIONS ...................................................................................... i
UNPACKING ................................................................................... ii
TABLE OF CONTENTS ................................................................. iii
1 PANEL DESCRIPTION ....................................................... 1 – 8
Front panel ........................................................................................... 1
Function display ................................................................................... 3
Rear panel ............................................................................................ 5
Microphone .......................................................................................... 6
Microphone keypad .............................................................................. 7
2 INSTALLATION ................................................................. 9 14
Installation methods ............................................................................. 9
Location .............................................................................................. 10
Single body installation ...................................................................... 10
Microphone connection ...................................................................... 11
Separate installation ........................................................................... 11
Optional MB-58 installation ................................................................ 12
Battery connection ............................................................................. 13
DC power supply connection ............................................................. 13
Antenna installation ............................................................................ 14
3 SETTING A FREQUENCY .............................................. 15 19
Preparation ......................................................................................... 15
Lock functions .................................................................................... 16
Using a tuning dial .............................................................................. 17
Using [Y]/[Z] switches ....................................................................... 17
Tuning step selection ......................................................................... 18
Using the keypad ............................................................................... 19
4 BASIC OPERATION ....................................................... 20 – 26
Receiving ........................................................................................... 20
Monitor function .................................................................................. 21
Audio mute function ........................................................................... 21
Avionics band receive ........................................................................ 21
Sub band access ................................................................................ 22
Sub band mute/sub band busy beep ................................................. 23
Para-watch ......................................................................................... 24
Transmitting ........................................................................................ 25
Selecting the output power ................................................................. 25
Crossband full duplex ......................................................................... 26
One-touch PTT function ..................................................................... 26
5 REPEATER OPERATION ............................................... 27 – 31
Operation ........................................................................................... 27
Subaudible tones ............................................................................... 29
Offset frequency ................................................................................. 30
Auto repeater ..................................................................................... 31
6 MEMORY OPERATION .................................................. 32 – 36
General description ............................................................................ 32
Memory channel selection ................................................................. 32
Programming a memory channel ....................................................... 33
Programming a memory channel via the microphone .......................... 34
Transferring memory contents ........................................................... 35
Memory clearing ................................................................................. 36
7 CALL CHANNEL OPERATION ...................................... 37 38
Calling up a call channel contents ...................................................... 37
Transferring call channel contents ..................................................... 37
Programming a call channel ............................................................... 38
8 SCRATCH PAD MEMORY .............................................. 39 40
What is a scratch pad memory? ......................................................... 39
IC-2710H.qxd 02.2.8 16:55 Page iii (1,1)
iv
Calling up a scratch pad memory ....................................................... 39
Transferring scratch pad memory contents ........................................ 40
9 SCAN OPERATION ........................................................ 41 46
Scan types ......................................................................................... 41
Start/stop scan ................................................................................... 42
Programming scan edges .................................................................. 43
Programming scan edges via the microphone ................................... 44
Skip channel setting ........................................................................... 45
Scan resume condition ....................................................................... 46
10 PRIORITY WATCH .......................................................... 47 – 48
Priority watch types ............................................................................ 47
Priority watch operation ...................................................................... 48
11 DTMF MEMORY ENCODER .......................................... 49 – 52
Programming a DTMF code ............................................................... 49
Clearing the DTMF memory contents ................................................ 49
Programming a DTMF code via the microphone ............................... 50
Transmitting a DTMF code ................................................................. 51
DTMF speed ...................................................................................... 52
12 POCKET BEEP AND TONE SQUELCH ........................ 53 – 55
Pocket beep operation ....................................................................... 53
Tone squelch operation ...................................................................... 54
Tone scan ........................................................................................... 55
13 PAGER AND CODE SQUELCH ..................................... 56 – 62
Pager function .................................................................................... 56
Code channels ................................................................................... 57
Code programming ............................................................................ 58
Pager operation .................................................................................. 59
Code squelch function ........................................................................ 61
Code squelch operation ..................................................................... 62
14 EXTERNAL DTMF REMOTE .......................................... 63 – 64
15 OPTIONAL UNIT INSTALLATION ......................................... 65
Optional unit installation ..................................................................... 65
16 WIRELESS OPERATION ................................................ 66 – 71
Connection ......................................................................................... 66
HM-90
WIRELESS MICROPHONE
............................................................ 66
EX-1759 installation ........................................................................... 67
HM-90 switches .................................................................................. 68
Microphone address ........................................................................... 71
17 OTHER FUNCTIONS ...................................................... 72 74
Beep tones on/off ............................................................................... 72
Time-out timer .................................................................................... 72
Auto power-off .................................................................................... 73
Cooling fan setting ............................................................................. 73
Microphone [F-1]/[F-2] keys ............................................................... 74
Display dimmer setting ....................................................................... 74
Demonstration display ........................................................................ 74
18 MAINTENANCE .............................................................. 75 77
Troubleshooting .................................................................................. 75
Fuse replacement .............................................................................. 77
Partial resetting .................................................................................. 77
Total resetting ..................................................................................... 77
19 SPECIFICATIONS .................................................................. 78
20 OPTIONS ........................................................................ 79 – 80
21 MODE ARRANGEMENT CHART ................................... 81 – 82
IC-2710H.qxd 02.2.8 16:55 Page iv (1,1)
PANEL DESCRIPTION
1
1
q POWER SWITCH [POWER]
Turns power ON and OFF when pushed for 1 sec.
w TUNING DIALS
Select the operating frequency (p. 17), the memory
channel (p. 32), the contents of the set mode display
(p. 82) and the scanning direction. (p. 42)
Select the main band when pushed. (p. 15)
When the sub band is selected, activate the sub band
function when pushed and held. (p. 22)
When the main band is selected, change the operating
band (for para watch) when pushed and held. (p. 24)
e SQUELCH CONTROLS [SQL(MONI)]
Vary the squelch level. (p. 20)
RF attenuator activates and increases the attenuation when
rotated clockwise to the center position and further.
Toggles squelch opened and closed when pushed.
Transmit frequency is automatically selected when squelch
opens.
r VOLUME CONTROLS [VOL(SET L)]/[VOL(SET D)]
Adjust the audio levels. (p. 20)
Select set mode when pushed. (p. 82)
Toggles the lock function ON/OFF when pushed and
held [SET
(L)]. (p. 16)
Allows you to adjust the display brightness when
pushed and held [SET
(D)]. (p. 74)
V MHz
SCAN
S.MW MW
LOW DUP POWER DTMF T
MONI
SQL
MONI
SQL
SET L
VOL
SET D
VOL
M CALL
PRIO
V MHz
SCAN
S.MW MW
M CALL
PRIO
LOCK
VFO
CALL
MR
SUB
BAND
F-2
F-1
Function display (p. 3)
Front panel (remote controller)
IC-2710H.qxd 02.2.8 16:55 Page 1 (1,1)
1
PANEL DESCRIPTION
2
t VFO/MHz SWITCHES [V/MHz(SCAN)]
Select and toggle VFO mode and 1 MHz tuning display.
Start a scan when pushed and held. (p. 42)
y MEMORY/CALL CHANNEL SWITCHES
[M/CALL(PRIO)]
Select and toggle memory mode or a call channel.
(pgs. 32, 37)
Activate the priority watch function when pushed and
held. (p. 47)
u SELECT MEMORY/MEMORY WRITE SWITCHES
[S.MW(MW)]
Select a memory channel for programming. (p. 33)
Program selected memory when pushed and held. (p. 33)
i OUTPUT POWER/DUPLEX SWITCH [LOW(DUP)]
Each push changes the output power selection. (p. 25)
There are 3 output powers available: low, mid and high.
Push and hold to select a duplex setting. (p. 27)
There are 3 duplex settings available: minus duplex (“–
DUP appears, plus duplex (+ DUP appears) and simplex.
o DTMF/TONE SWITCH [DTMF(T)]
Turns DTMF memory encoder ON and OFF for au-
topatch operation. (p. 49)
When an optional UT-49 is installed, activates the DTMF
memory, pager or code squelch function in sequence.
Turns the subaudible tone encoder ON and OFF for re-
peater access when pushed and held. (p. 27)
When an optional UT-104 is installed, activates the subaudi-
ble tone encoder, pocket beep or tone squelch function in
sequence.
!0 MICROPHONE
To connect the supplied microphone, detach the front
panel in advance.
Multi-function keypad can be accessed by removing
the keypad cover. (p. 7)
Be careful not to lose the cover.
!1 FRONT PANEL RELEASE LATCH
While pushing this latch, slide the front panel to the left to
remove it.
!2 MICROPHONE CONNECTOR
Connect the supplied microphone or optional EX-1759
IN
-
FRARED RECEIVER
. (p. 11)
!3 CABLE GUTTERS
Pass the microphone cable through one of the gutters
when attaching the front panel.
!4 MICROPHONE RELEASE
Push to release the microphone.
IC-2710H.qxd 02.2.8 16:55 Page 2 (1,1)
1
PANEL DESCRIPTION
3
q SUB BAND ACCESS INDICATORS (p. 22)
Appear when the sub band access function is activated
and indicate the function control band via the microphone
and some front panel switches (except transmitting).
w MAIN BAND INDICATORS (p. 15)
Indicate the main band for transmit and function control.
e TRANSMIT INDICATORS (p. 25)
Appear while transmitting.
Flash while transmitting with the one-touch PTT func-
tion (p. 26).
r FREQUENCY READOUTS
Show the operating frequency, set mode contents, etc.
The decimal point of the frequency flashes while scanning.
(p. 42)
•“d appears in place of the 100 MHz while the DTMF memory
function is in use; when optional units are installed, P, or C
appears in place of the 100 MHz while the pager or code
squelch functions are in use, respectively. (pgs. 49, 59, 61)
t DUPLEX INDICATORS (p. 27)
DUP–” or DUP appear during semi-duplex operation (re-
peater operation).
y TONE INDICATORS
T appears while the subaudible tone encoder is in
use. (p. 27)
T SQL appears while the optional tone squelch func-
tion is in use. (p. 54)
T SQLS appears while the optional pocket beep
function is in use. (p. 53)
BUSY
LOW
LOW
MUTE
PRIO
DUP
SKIP SKIP
BUSY
MUTE
PRIO
T SQL
DUP
TSQL
TOT
AO
REMO
q
wert y ui
o
!0
!1
q
o
!0
!1
!2!3!4!5!6 !2!3!4!5!6!7
werty
Function display
IC-2710H.qxd 02.2.8 16:55 Page 3 (1,1)
4
1
PANEL DESCRIPTION
u EXTERNAL DTMF CONTROL INDICATOR (p. 63)
Appears when the optional external DTMF control function
is in use.
Available for the U.S.A. version only.
i TOT (TIME-OUT TIMER) INDICATOR (p. 72)
Appears while the time-out timer has been activated.
o AUDIO MUTE INDICATORS (p. 21)
Appear when the audio mute function is activated via mi-
crophone control.
This function is cancelled when any switch or control is oper-
ated.
!0 PRIORITY WATCH INDICATORS (p. 48)
Appear while the priority watch is activated; ash while the
watch is paused.
!1 OUTPUT POWER INDICATORS (p. 25)
LOW appears for low output power. (5 W)
LOW appears for mid output power. (10 W)
No indicator appears for high output power.
!2 MEMORY CHANNEL READOUTS
Show the selected memory channel numbers. (p. 32)
Only 2 capital L”’s appear while the frequency lock
function is in use. (p. 16)
A capital C appears while on a call channel (p. 37)
L1L3 appear when a scratch pad memory is se-
lected. (p. 39)
A small c appears when VFO mode is selected from
the call channel or a scratch pad memory (pgs. 37, 39)
!3 SKIP INDICATORS (p. 45)
Appear when the displayed memory channel is specied
as a skip channel.
!4 MEMORY INDICATORS (p. 32)
Appear when memory mode is selected.
!5 S/RF INDICATORS (p. 25)
Show the relative signal strength while receiving sig-
nals.
Show the output power selection while transmitting.
!6 BUSY INDICATORS (p. 20)
Appear while a signal is being received or the squelch is
open.
!7 AUTO POWER-OFF INDICATOR (p. 73)
Appears while the auto power-off function is in use.
IC-2710H.qxd 02.2.8 16:55 Page 4 (1,1)
1
PANEL DESCRIPTION
5
Rear panel
q
w
e
r
q ANTENNA CONNECTOR [ANT]
Accepts a 50 dual band antenna with a PL-259 connec-
tor. (p. 14)
w SPEAKER JACK 1 [144 MHz SP]
Connects a 48 speaker, if required. Outputs the 144
MHz bands audio. See the table at right for details.
e SPEAKER JACK 2 [430(440) MHz SP]
Connects a 48 speaker, if required. Outputs both
bands audio when [430(440) MHz SP] has no connection.
r POWER RECEPTACLE [DC13.8V]
Accepts 13.8 V DC with the supplied DC power cable.
D Speaker information
Connected
speaker
VHF band audio UHF band audio
With no exter-
nal speakers
Internal speaker (mixed audio)
[144 MHz SP]
only
External speaker
[430(440) MHz
SP] only
External speaker (mixed audio)
2 external
speakers
External speaker via
[144 MHz SP]
External speaker via
[430(440) MHz SP]
Internal speaker
IC-2710H.qxd 02.2.8 16:55 Page 5 (1,1)
1
PANEL DESCRIPTION
6
Microphone
LOCK
VFO
CALL
MR
SUB
BAND
MW
FUNC
A
CLR
D-OFF
B
SET
PTT-M
3
PRIO
DTMF
6
LOW
AFC-OFF
2
SCAN
CSQL
5
MID
AFC
1
MONI
PGR
4
HIGH
T-OFF
C
ENT
TSQL
9
SIMP
16
KEY LOCK
#
TSQLS
8
DUP+
TONE-2
0
TONE
7
DUP
TONE-1
F-2
F-1
DTMF-S
MUTE
D
SQLSQLVOLVOL
Mic element
q
w
e
r
t
y
u
i
o
q UP/DOWN SWITCHES [Y]/[Z]
Push either switch to change the operating frequency,
memory channel, set mode contents, etc. (pgs. 17, 32)
Push and hold either switch to start scanning. (p. 42)
w PTT SWITCH
Push and hold to transmit; release to receive. (p. 25)
Toggles between transmitting and receiving while the
one-touch PTT function is in use. (p. 26)
e VFO SWITCH [VFO(LOCK)]
Push to select VFO mode.
Push and hold to toggle the lock function ON and OFF.
r MEMORY SWITCH [MR(CALL)]
Push to select memory mode. (p. 32)
Push and hold to select the call channel. (p. 37)
t ACTIVITY INDICATOR
Lights red while a key is pushed; lights green while the
one-touch PTT function is in use.
y BAND SWITCH
Push to toggle the main band. (p. 15)
Push and hold to turn the sub band access function ON
and OFF. (p. 22)
u FUNCTION SWITCHES [F-1]/[F-2] (p. 74)
Assign your desired key function from the front panel
switches.
Default settings are VHF and UHF tuning dials to [F-1] and [F-2],
respectively for quick band selection.
i FUNCTION INDICATOR
Lights yellow while [FUNC] is activatedindicates the
secondary function of switches can be accessed.
Lights green when [DTMF-S] is activatedDTMF sig-
nals can be transmitted with the keypad. (p. 51)
o KEYPAD
Used for controlling the transceiver, transmitting a DTMF
encoder, etc. See pgs. 7 and 8 for function details.
IC-2710H.qxd 02.2.8 16:55 Page 6 (1,1)
1
PANEL DESCRIPTION
7
Microphone keypad
FUNCTION
SECONDARY FUNCTION (after )
OTHER FUNCTIONS
Toggles between opening and closing the
accessed bands squelch. (p. 20)
No secondary function.
After :
Transmit the appropriate
DTMF code or push [1] to
[8] to transmit the DTMF
memory contents when
the DTMF memory en-
coder is activated. (p. 51)
Starts and stops scanning. (p. 42)
Starts tone scan when an optional tone
squelch is in use. (p. 55)
No secondary function.
Starts and stops priority watch. (p. 48)
Turns the one-touch PTT function ON and
OFF. (p. 26)
Selects high output power. (p. 26) Turns the optional pager function ON.(p. 59)
Selects middle output power. (p. 26) Turns the optional code squelch function
ON. (p. 62)
Selects low output power. (p. 26)
Turns the DTMF memory encoder function
ON. (p. 50)
Selects duplex. (p. 28)
Turns the subaudible tone encoder ON.
(p. 28)
Selects +duplex. (p. 28)
Turns the optional pocket beep function ON.
(p. 53)
Selects simplex (p. 28)
Turns the optional tone squelch function
ON. (p. 54)
Increases the audio output. (p. 20)
While being pushed, transmits a 1750 Hz
tone. (p. 28)
AFC
1
MONI
AFC-OFF
2
SCAN
PTT-M
3
PRIO
PGR
4
HIGH
CSQL
5
MID
DTMF
6
LOW
TONE
7
DUP
TSQLS
8
DUP+
TSQL
9
SIMP
TONE-2
0
VOL
KEY
IC-2710H.qxd 02.2.8 16:55 Page 7 (1,1)
1
PANEL DESCRIPTION
8
KEY FUNCTION
SECONDARY FUNCTION (after )
OTHER FUNCTIONS
Clears a digit before entry. (p. 19)
Cancels the scan, priority watch, pager,
code squelch or DTMF memory function.
(pgs. 42, 48, 51, 59, 62)
Writes the VFO contents into the memory
channel or call channel. (pgs. 34, 38)
Advances the memory channel number
when continuously pushed after program-
ming is completed. (p. 34)
After :
Transmit the appropriate
DTMF code. (p. 51)
Enters set mode and advances the set
mode selection order. (p. 82)
Turns the pager, code squelch, DTMF mem-
ory or DTMF remote function OFF.
(pgs. 59, 62, 63)
Sets the keypad for numeral input.
(p. 19)
Decreases the set mode selection order
after entering set mode. (p. 82)
Turns the subaudible tone encoder, pocket
beep or tone squelch OFF. (pgs. 28, 53, 54)
Increases the squelch level. (p. 20)
The [SQL] control on the front panel has prior-
ity when rotated.
Mutes both bands audio signals. (p. 21)
Mute function is released when any operation is
performed.
Decreases the squelch level. (p. 20)
The [SQL] control on the front panel has prior-
ity when rotated.
Locks the digit keys on the keypad (including
the AD, # and
M
keys. (p. 16)
Decreases the audio output. (p. 20) Sends a 1750 Hz tone signal for 1 sec.
(p. 28)
MW
A
CLR
D-OFF
B
SET
16
KEY LOCK
#
SQL
T-OFF
C
ENT
MUTE
D
SQL
TONE-1
M
VOL
IC-2710H.qxd 02.2.8 16:55 Page 8 (1,1)
D Separate installation
Optional OPC-600
SEPARATION CABLE
(3.5 m; 11.5 ft) or
OPC-601 (7.0 m; 23.0 ft) is necessary.
Optional MB-58
REMOTE CONTROLLER BRACKET
is available
for front panel mounting.
Optional MB-65
MOUNTING BASE
is available for increasing
front panel mounting possibilities (MB-58 is necessary).
Optional OPC-440
MICROPHONE CABLE
(5.0 m; 16.4 ft) and
OPC-647 (2.5 m; 8.2 ft) are available to extend the micro-
phone cable.
Optional OPC-441
SPEAKER CABLE
(5.0 m; 16.4 ft) is avail-
able to extend the speaker cable.
INSTALLATION
2
9
Installation methods
D Single body installation
It is not necessary to purchase a mounting bracket. The
supplied mounting bracket (or optional MB-17A) can be
used for installation.
Main body
Front panel
IC-2710H.qxd 02.2.8 16:55 Page 9 (1,1)
2
INSTALLATION
10
Location
Select a location which can support the weight of the trans-
ceiver and does not interfere with driving in any way. We rec-
ommend the locations shown in the diagram below.
Single body installation
Drill 4 holes where the mounting bracket is to be installed.
Approx. 5.56 mm (
3
16 in) when using nuts; approx. 23 mm (
1
16
in) when using self-tapping screws.
Insert the supplied screws, nuts and washers through the
mounting bracket and tighten.
Adjust the angle for the clearest view of the function dis-
play.
NEVER place the transceiver or remote controller where
normal operation of the vehicle may be hindered or where
it could cause bodily injury.
NEVER place the transceiver or remote controller where
air bag deployment may be obstructed.
DO NOT place the transceiver or remote controller where
hot or cold air blows directly onto it.
AVOID placing the transceiver or remote controller in di-
rect sunlight.
EXAMPLE INSTALLATION LOCATIONS
20°
Mounting nut
Mounting
bracket
When using
self-tapping
screws.
Nut
Spring washer
Flat washer
Flat washer
Spring
washer
IC-2710H.qxd 02.2.8 16:55 Page 10 (1,1)
2
INSTALLATION
11
Microphone connection
The microphone connector is located behind the front panel.
Connect the supplied microphone as follows:
Push the release button, then detach the remote controller
as shown below.
Connect the supplied microphone to the microphone con-
nector.
Reattach the remote controller to the main body.
To remove the microphone, push the release button as
above.
Separate installation
Using an optional OPC-600/601
SEPARATION CABLE
, the front
panel can be separated from the main body, doubling as a re-
mote controller.
Detach the front panel as shown at left.
Connect a separation cable to the front panel and to the
main body using the supplied screws as illustrated below.
mic release
Push
Release
button
OPC-600 or OPC-601
Rear of front panel Main body
8 V OUT
Freq. up/down
8 V control IN
PTT
Mic AF ()
Mic AF (+)
Ground
Data IN
Microphone pin assignments
IC-2710H.qxd 02.2.8 16:55 Page 11 (1,1)
2
INSTALLATION
12
Optional MB-58 installation
The optional MB-58
REMOTE CONTROLLER BRACKET
is avail-
able for separate installation.
Drill 2 or 4 holes where the bracket or mounting base is to
be installed, respectively.
Approx. 4 mm (
1
8 in) when using nuts; approx. 12 mm (
1
16 in)
when using self-tapping screws.
Insert the supplied screws, bolts and washers through the
mounting base and tighten.
Adjust the angle for the clearest view of the function dis-
play and tighten 2 screws when the mounting base is used.
Bracket
When using self-
tapping screws.
Mounting
base
Mounting
bolt
Attach the supplied Velcro pads (large) to the remote con-
troller and bracket.
Attach the supplied Velcro pad (small) or rubber pad to the
bracket as shown below; then attach the remote controller.
D When using the MB-65
MB-58 IC-2710H remote controller
MB-58
MB-65
Adjust the viewing
angle for maximum
visibility of the
function display.
IC-2710H.qxd 02.2.8 16:55 Page 12 (1,1)
2
INSTALLATION
13
Battery connection DC power supply connection
Use a 13.8 V DC power supply with more than 12 A capabil-
ity. An optional IC-PS30
DC POWER SUPPLY
is available for
using the transceiver with a DC power supply in your home.
Make sure the ground terminal of the DC power supply is
grounded.
NEVER connect the transceiver directly to a 24 V battery.
DO NOT use the cigarette lighter socket for power con-
nections.
Attach a rubber grommet when passing the DC power
cable through a metal plate to prevent short circuits.
CONNECTING TO A DC POWER SOURCE
See p. 77 for fuse replacement.
Fuses
20 A
black
red
red
Grommet
black
12 V
Supplied
DC power cable
CONNECTING TO A DC POWER SUPPLY
See p.77 for fuse replacement.
DC power
supply 13.8 V
to an
AC
outlet
Fuses
20 A
black
red
IC-2710H.qxd 02.2.8 16:55 Page 13 (1,1)
2
INSTALLATION
14
Antenna installation
D Antenna location
To obtain maximum performance from the transceiver, select
a high-quality antenna and mount it in a good location. A non-
radial antenna should be used when using a magnetic mount.
D Antenna splitter
You can use a dual band antenna because a duplexer is in-
stalled in the transceiver. However, an external duplexer must
be connected when using a separate antenna for each band.
D Antenna connector
The antenna uses a PL-259 connector.
30 mm
10 mm (soft solder)
10 mm
12 mm
solder solder
Soft
solder
Coupling ring
PL-259 CONNECTOR
Slide the coupling ring
down. Strip the cable
jacket and soft solder.
Slide the connector
body on and solder it.
Screw the coupling
ring onto the connec-
tor body.
Strip the cable as
shown at right. Soft
solder the center con-
ductor.
(10 mm
3
8 in)
Roof-mount antenna
(Drill a hole or use a magnetic mount.)
Gutter-mount antenna
Trunk-mount
antenna
IC-2710H.qxd 02.2.8 16:55 Page 14 (1,1)
SETTING A FREQUENCY
3
15
Preparation
D Turning power ON
Push [POWER] for 1 sec. to turn power ON.
D Main band
The IC-2710H can receive 144 MHz and 430(440) MHz band
signals simultaneously. Function access or frequency
changes affect the main band only. In addition, signals can
be transmitted on the main band only. Set the desired band
as the main band.
Push the desired bands tuning dial to select the main band.
•“Q indicates the main band.
Push [BAND] to toggle the main band selection
between the 144 and 430(440) MHz bands.
D VFO and memory modes
The transeiver has 2 normal operating modes: VFO mode
and memory mode. You can select VFO mode or memory
mode independently on each band.
Push the desired bands [V/MHz] to select VFO mode when
the transceiver is not in VFO mode.
If VFO mode is already selected, the digits below 100 kHz disap-
pear. In this case, push [V/MHz] again (or push twice depending on
version).
Push [VFO] to select VFO mode.
The microphone controls the main band only (or using
sub band access; p. 22). Push [BAND] to toggle the
main band, then push [VFO], if necessary.
Push [POWER] for 1 sec.
BAND
Indicates memory modeVFO mode is selected
VFO
IC-2710H.qxd 02.2.8 16:55 Page 15 (1,1)
3
SETTING A FREQUENCY
16
Lock functions
To prevent accidental frequency changes and unnecessary
function access, use the lock function. The transceiver has 2
different lock functions.
D Frequency lock
This function locks the tuning dials and switches electronically
and can be used together with the microphone lock function.
Push and hold [
(SET)L] until L appears in the memory chan-
nel readout to activate the function.
To cancel the function, push and hold [
(SET)L] until L disappears.
[PTT], [BAND], [MONI], [MUTE], [VOL] and [SQL] can be used while
the frequency lock function is in use. Also, DTMF tones or DTMF
memory contents can be transmitted from the microphone.
Push and hold [(VFO)LOCK] for 1 sec. to toggle
the function ON and OFF.
D Microphone keypad lock
This function locks the microphone keypad.
Push [FUNC] then [
A16 KEYLOCK] to toggle
the microphone keypad lock function ON and
OFF.
[PTT] and the 7 keys on the upper half of the mi-
crophone can be used.
All switches on the transceiver can be used.
The keypad lock function is released when the
power is turned OFF then ON again.
2 Ls appear while the frequency lock function
is in use.
16 KEY LOCK
#
LOCK
IC-2710H.qxd 02.2.8 16:55 Page 16 (1,1)
3
SETTING A FREQUENCY
17
Using a tuning dial
Rotate the desired bands tuning dial to set the frequency.
If VFO mode is not selected, push the same bands [V/MHz] to
select VFO mode.
Frequency changes according to the selected tuning steps.
(p. 18)
For the 1 MHz frequency setting, rotate the same bands
tuning dial after pushing [V/MHz].
Pushing [V/MHz] for 1 sec. starts a scan function. If this happens,
push [V/MHz] again to stop the scan.
D 10 MHz steps
Some versions have 10 MHz tuning steps. For these versions
the [V/MHz] switch selects 10 MHz, 1 MHz then kHz steps in
sequence.
Using [Y]/[Z] switches
Push [Y] or [Z] to set the main bands frequency.
If VFO mode is not selected, push [VFO] to select it.
Frequency changes according to the selected tuning
steps. (p. 18)
Pushing [Y] or [Z] for more than 0.5 sec. activates a
scan. If this happens, push [Y] or [Z] again to stop it.
NOTE: 1 MHz steps cannot be used via the [Y]/[Z]
switches
The display shows that the 1 MHz tuning step is
selected for the VHF band.
YZ
59
IC-2710H.qxd 02.2.8 16:55 Page 17 (1,1)
3
SETTING A FREQUENCY
18
Tuning step selection
Tuning steps are the minimum frequency change increments
when you rotate the tuning dial or push the [Y] or [Z]
switches on the microphone. The following tuning steps are
available:
5 kHz 10 kHz 12.5 kHz 15 kHz
20 kHz 25 kHz 30 kHz 50 kHz
NOTE: For convenience, select a tuning step that
matches the frequency intervals of repeaters in your area.
Push the desired bands tuning dial.
Push the selected bands [V/MHz] to select VFO mode if
another mode has been selected.
Push the selected bands [
(VOL)SET] one or more times
until tS appears as shown below.
Pushing [(SQL)MONI] reverses the order of selection.
Cancel the DTMF memory or optional pager/code squelch in ad-
vance. (pgs. 49, 59, 62)
Rotate the selected bands tuning dial to select the tuning
step.
Push the selected bands tuning dial to exit set mode.
Ä Push [BAND] to set the main band, if neces-
sary.
Å Push [VFO] to select VFO mode.
Ç Push [FSET] one or more times until tS ap-
pears as shown previously.
Push [ENT] to reverse the order of selection.
Cancel the DTMF memory or optional pager/code
squelch in advance. (pgs. 49, 59, 62)
É Push [Y] or [Z] to select the tuning step.
Ñ Push [CLR] to exit set mode.
USING
SET MODE
25 kHz tuning step15 kHz tuning step
SET
B
IC-2710H.qxd 02.2.8 16:55 Page 18 (1,1)
3
SETTING A FREQUENCY
19
Using the keypad
The frequency can be directly set via numeral
keys on the microphone.
Ä Push [BAND] to set the main band, if necessary.
Å Push [VFO] to select VFO mode.
Ç Push [ENT] to activate the keypad for digit input.
É Push 5 keys to input a frequency.
When a digit is mistakenly input, push [ENT] to clear the input,
then input from the 1st digit.
Pushing [CLR] clears input digits and retrieves the frequency.
Ñ Push [Y] or [Z] to make adjustments below the 10 kHz
digit, if desired.
ENT
C
[EXAMPLE]: Setting the frequency to 145.360 MHz.
[EXAMPLE]: Setting the frequency to 446.325 MHz. (When the 25 kHz tuning step is selected in UHF.)
BAND
then
VFO
C
ENT
3
PRIO
5
MID
1
MONI
4
HIGH
6
LOW
BAND
then
VFO
C
ENT
3
PRIO
6
LOW
4
HIGH
4
HIGH
0
VOL
IC-2710H.qxd 02.2.8 16:55 Page 19 (1,1)
BASIC OPERATION
4
20
Receiving
The IC-2710H can receive 144 MHz and 430(440) MHz band
signals simultaneously.
Push [POWER] for 1 sec. to turn power ON.
Set the audio levels.
Push [
(SQL)MONI] to open the squelch.
Rotate the [VOL] control to adjust the audio output level.
Push [
(SQL)MONI] again to close the squelch.
Set the squelch levels.
Rotate [SQL] fully counterclockwise in advance.
Rotate [SQL] clockwise until the noise just disappears.
When interference is received, rotate [SQL] clockwise
again for attenuator operation.
Set the operating frequency. (pgs. 1519)
When receiving a signal on the set frequency, squelch
opens and the transceiver emits audio.
•“BUSY appears and the S/RF indicator shows the relative signal
strength on the received band.
BUSY
159
When receiving a signal on VHF.
The volume and squelch levels can be adjusted via the mi-
crophone. However, levels return to the front panel setting
when power is turned OFF or a front panel control is adjusted.
Ä Push [POWER] on the transceiver for 1 sec. to
turn power ON.
Å Set the audio levels.
Select the desired band.
Push [MONI], then push [BZVOL] or
[IYVOL] to adjust the audio level.
Push [MONI] again to close the squelch.
Ç Set the squelch level using [AZSQL] or
[HYSQL], if desired.
É Set the operating frequency. (pgs. 1519)
CONVENIENT
RF attenuator: The transceiver has an RF attenuator related
to the [SQL] setting. The attenuator is automatically activated
when [SQL] is rotated further than the 12 oclock position.
Approx. 10 dB attenuation is obtained at full rotation.
BAND
VOL
VOL
Appears while setting volume Appears while setting squelch
BUSY
1 1
IC-2710H.qxd 02.2.8 16:55 Page 20 (1,1)
4
BASIC OPERATION
21
Avionics band receive
(U.S.A. version only)
AM mode can be selected over the range of 118.000 to
135.995 MHz for reception of avionics-related broadcasts.
Push and hold [
(SQL)MONI] to toggle between AM and FM
modes.
Mode selection cannot be performed via the microphone.
NOTE: The avionics band can be selected in the left band
only, even when the para watch fuinction is in use.
CONVENIENT
The tuning steps for the avionics band are available sepa-
rately from those for other ranges.
159
Appears when AM
mode is selected.
Monitor function
This function is used to listen to weak signals without disturb-
ing the squelch setting or to open the desired bands squelch
manually even when the optional mute functions such as tone
squelch, pager functions, etc., are in use.
Push the desired bands [MONI] to open the desired bands
squelch.
Push [MONI] again to cancel the function.
While duplex is ON for repeater operation, the transmitting fre-
quency can be monitored with [MONI].
Ä Push [BAND] to change bands, if necessary.
Å Push [MONI] to open the main bands
squelch.
Push [MONI] again to cancel the function.
Audio mute function
This function mutes both bands audio signals
without disturbing the volume settings.
Ä Push [FUNC] then [HMUTE] to mute both bands audio signals.
•“MUTE appears for both bands.
Å Push [ECLR] (or any other key) to cancel the function.
•“MUTE disappears.
MONI
MUTE
H
IC-2710H.qxd 02.2.8 16:55 Page 21 (1,1)
4
BASIC OPERATION
22
Sub band access
This function allows you to change sub band settings such as
duplex settings, especially useful from the microphone, during
transmission standby on the main band.
Its easy to access the sub band and return to the main band
with the band switch.
Push and hold the sub bands tuning dial until ^ ap-
pears as shown below.
If the [PTT] is pushed at this time, transmit is on the main band.
If the main bands tuning dial is mistakenly pushed and held, the
para-watch function is activated. In this case, push the main
bands tuning dial for 1 sec. and repeat again. (p. 24)
Activate functions such as duplex setting, subaudible
tones, etc.
To exit sub band access, push the main bands tuning dial.
To switch from the sub band to the main band, push the sub
bands tuning dial.
Pushing and holding the sub bands tuning dial until ^ dis-
appears also exits sub band access.
The sub band access function is also available from the mi-
crophone and is useful for setting the sub bands frequency,
etc. during transmission standby on the main band.
Ä Push and hold [(BAND)SUB].
•“^ appears.
If the [PTT] is pushed at this time, transmit is on the
main band.
Å Set the sub bands operating frequency or acti-
vate functions.
Ç To exit sub band access, push and hold
[
(BAND)
SUB] again.
•“^ disappears.
To switch from the sub band to the main band (for
transmitting), push [(BAND)
SUB] (momentarily).
^ appears
BAND
IC-2710H.qxd 02.2.8 16:55 Page 22 (1,1)
4
BASIC OPERATION
23
Sub band mute/
sub band busy beep
The sub band mute function automatically cuts out sub band
AF signals when both main and sub band signals are re-
ceived simultaneously.
The sub band busy beep sounds when the sub bands
squelch is closed to inform you that the sub bands squelch
has been opened.
While pushing [(VOL)SET L] (on the left side of the trans-
ceiver), push [POWER] to enter initial set mode.
Push [SET] one or more times until Sub appears in the
display as shown above.
Push [MONI] to reverse the order of selection.
USING
INITIAL SET MODE
The display shows that the sub
band mute is turned ON and
the sub band busy beep is
turned OFF.
Common setting for each band
Rotate the main bands tuning dial to set the condition.
Push [POWER] momentarily to exit initial set mode.
DISPLAY SUB BAND MUTE BUSY BEEP
Sub-oF OFF OFF
Sub-oF S
OFF ON
Sub-on ON OFF
Sub-on S
ON ON
IC-2710H.qxd 02.2.8 16:55 Page 23 (1,1)
4
BASIC OPERATION
24
Para-watch
The IC-2710H can simultaneously receive 2 signals on the
same band, 144 MHz or 430(440) MHz band, using the para-
watch function.
[EXAMPLE]
Can be switched
between VHF and
UHF.
Push the desired band's tuning dial to assign the main
band.
Push and hold the main bands tuning dial until -144- or
-430- (or -440- for U.S.A. version) appears to change
the operating band.
Repeat step again to cancel the function.
NOTE:
Memory channels are common for the same band.
Transmitting on the para-watch frequency is possible and
the transmission quality is the same as usual. However,
the opposite bands audio is muted, even when both
bands are reversed.
The para-watch function cannot be activated from
the regular microphone keys. However, when the
tuning dial function is assigned to the user-pro-
grammable keys, [F-1] and [F-2], the para-watch
function can be activated via the microphone in
the same manner as described above.
F-1
F-2
Receiving a VHF signal
IC-2710H.qxd 02.2.8 16:55 Page 24 (1,1)
4
BASIC OPERATION
25
Transmitting
NOTE:
To prevent interference, listen on the frequency before
transmitting by pushing the main bands [
(SQL)MONI] or
the microphones [MONI].
To prevent howling and sensitivity rejection, AVOID set-
ting the 430(440) MHz band frequency near a multiple
of the 144 MHz band frequency, e.g. setting for
145 MHz and 435 MHz.
Push the desired bands tuning dial to select the main band
for transmitting.
Set the operating frequency. (pgs. 1519)
Select output power if desired. See section at right for details.
Push and hold [PTT] to transmit.
•“$ appears.
The S/RF indicator shows the output power selection.
The operating frequency, etc. are automatically programmed into
a scratch pad memory. See p. 39 for details.
One-touch PTT function is available. See p. 26 for details.
Speak into the microphone using your normal voice level.
DO NOT hold the microphone too close to your mouth or speak
too loudly. This may distort the signal.
Release [PTT] to return to receive.
Selecting the output power
The transceiver has 3 output power levels to suit your oper-
ating requirements. Lower output power during short-distance
communication may reduce interference to other stations and
reduces current consumption.
Push the desired bands tuning dial.
Push [LOW] one or more times to select the desired out-
put power.
The output power can be changed while transmitting.
CAUTION: Transmitting without an antenna may dam-
age the transceiver.
POWER
SELECTION
S/RF INDICATOR
VHF
UHF
HIGH 50 W 35 W
MID 10 W 10 W
LOW 5 W 5 W
159
LOW
1515
LOW
11
IC-2710H.qxd 02.2.8 16:55 Page 25 (1,1)
4
BASIC OPERATION
26
The microphone can select the desired output
power directly.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Push [HIGH] for high output power; [MID] for
middle output power; and [LOW] for low out-
put power.
The output power CANNOT be changed while trans-
mitting.
Crossband full duplex
The transceiver can receive a signal on the sub band while
transmitting on the main band. Using this capability, cross-
band full duplex operation is possible. No special setting is
necessary for crossband full duplex operation.
Set the desired transmit and receive frequencies on the
main and sub bands respectively for your transceiver.
(pgs. 1519)
Set the same frequencies, but set the receive band as the
main band for the other transceiver.
Push and hold [PTT] to operate with full duplex.
Transmitting and receiving activate simultaneously.
One-touch PTT function (at right) and time-out timer are useful
for crossband full duplex operation. (p. 72)
One-touch PTT function
The PTT switch can be operated as a one-touch
PTT switch (each push toggles transmit/receive).
Using this function, you can transmit without push-
ing and holding the PTT switch.
To prevent accidental, continuous transmissions
with the one-touch PTT function, the transceiver
has a time-out timer. See p. 72 for details.
Ä Push [FUNC] then [PTT-M] to turn the one-touch PTT
function ON.
The activity indicator lights green.
Å Push [PTT] to transmit and push again to receive.
Two beeps sound when transmission is started and a long beep
sounds when returning to receive.
•“$ ashes while transmitting with the one-touch PTT func-
tion.
Ç Push [FUNC] then [PTT-M] to turn the one-touch PTT
function OFF.
The activity indicator goes out.
HIGH
4
MID
5
LOW
6
PTT-M
3
IC-2710H.qxd 02.2.8 16:55 Page 26 (1,1)
REPEATER OPERATION
5
27
Operation
Push the desired bands tuning dial.
Set the receive frequency (repeater output frequency).
(pgs. 1519)
Push and hold [DUP] to select duplex or push it for 1 sec.
again for + duplex.
•“DUP –” or DUP appears to indicate the transmit frequency for
minus shift or plus shift, respectively.
When the auto repeater function is turned ON, (available for the
U.S.A. version only), steps and are not necessary. (p. 31)
Push and hold [(DTMF)T] to turn ON the subaudible tone
encoder, according to repeater requirements.
Refer to p. 29 for tone frequency settings.
When the repeater requires a different tone system, see the page
at right.
Push and hold [PTT] to transmit.
The displayed frequency automatically changes to the transmit
frequency (repeater input frequency).
The operating condition is automatically programmed into a
scratch pad memory. See p. 39 for details.
If oFF appears, conrm the offset frequency. (p. 30)
Release [PTT] to receive.
Push the selected bands [MONI] to check whether the
other stations transmit signal can be directly received or
not.
To return to simplex, push [DUP] for 1 sec., once or twice,
to clear the DUP indicator.
To turn OFF the subaudible tone encoder, push and hold
[
(DTMF)T].
•“T disappears.
When the optional UT-104 is installed, push and hold [(DTMF)T]
an additional 2 times (for a total of 3 times).
DUP
DUP
T
IC-2710H.qxd 02.2.8 16:55 Page 27 (1,1)
5
REPEATER OPERATION
28
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Set the receive frequency (repeater output fre-
quency). (pgs. 1519)
Ç Push [DUP] to select duplex; push
[DUP+] for + duplex.
É Push [FUNC] then [TONE] to turn ON the sub-
audible tone encoder according to repeater re-
quirements.
Refer to p. 29 for tone frequency setting.
When the repeater requires a different tone system,
see at right.
Ñ Push and hold [PTT] to transmit.
Ö Push and hold [MONI] to check whether the
other stations signal can be directly received.
Ü Release [PTT] to receive.
á To return to simplex operation, push [SIMP].
à To turn OFF the subaudible tone encoder, push
[FUNC], then [GT-OFF].
D DTMF tones
Push [DTMF-S], then push the keys of the desired
DTMF digits.
The function indicator lights green.
09, AD, M(E) and #(F) are available.
Cancel the DTMF memory encoder or optional pager/code
squelch function in advance. (pgs. 49, 59, 62)
Push [DTMF-S] again to return the keypad to normal
function control.
The transceiver has 8 DTMF memory channels for au-
topatch operation. See p. 49 for details.
D 1750 Hz tone
A 1750 Hz tone is required to access most
European repeaters. The microphone has 1750
Hz tone capability.
Ä Push [FUNC].
The mode indicator lights orange.
Å Push [BTONE-1] to transmit a 1750 Hz tone call signal for
1 sec.; push and hold [
ITONE-2] to transmit a 1750 Hz
tone call signal for an arbitrary period.
The mode indicator goes out automatically.
The optional HM-90 also has 1750 Hz tone capability.
DTMF S
TONE-1
TONE-2
DUP
7
DUP+
8
SIMP
9
IC-2710H.qxd 02.2.8 16:55 Page 28 (1,1)
5
REPEATER OPERATION
29
Subaudible tones
Push the desired bands tuning dial.
Select the mode/channel you wish to set the subaudible
tone frequency to, such as VFO mode or memory/call
channel.
Push [SET] one or more times until T appears and
ashes as shown above.
Push [MONI] to reverse the order of selection.
Cancel the DTMF memory encoder or optional pager/code
squelch function in advance. (pgs. 49, 59, 62)
Rotate the selected bands tuning dial to select and set the
desired frequency.
Push the desired bands tuning dial to exit set mode.
NOTE: The subaudible tone frequency can be set in a
memory channel temporarily. However, the set contents
are cleared once the memory/call mode is selected. To
store the tone frequency permanently, overwrite the chan-
nel information.
USING
SET MODE
159
T
Separate setting for each band
The display shows that an
88.5 Hz subaudible tone fre-
quency is set.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Set the mode/channel you wish to set the sub-
audible tone frequency to, such as VFO mode,
memory/call channel or scratch pad memory.
The subaudible tone frequency is independently pro-
grammed into each mode or channel.
Ç Push [FSET] one or more times until T ap-
pears and ashes as shown at left.
Pushing [GENT] reverses the order of selection.
Cancel the DTMF memory encoder or optional
pager/code squelch function in advance. (pgs. 49,
59, 62)
É Push [Y] or [Z] to select and set the desired
frequency.
Pushing and holding [Y] or [Z] changes the fre-
quency continuously.
Ñ Push [ECLR] to exit set mode.
Subaudible tone frequency list (unit: Hz)
SET
B
67.0
79.7 94.8 110.9 131.8 156.7 171.3 186.2
69.3 82.5 97.4 114.8 136.5 159.8 173.8 189.9
71.9 85.4 100.0 118.8 141.3 162.2 177.3 192.8
74.4 88.5 103.5 123.0 146.2 165.5 179.9 196.6
77.0
91.5 107.2 127.3 151.4 167.9 183.5 199.5
203.5
206.5
210.7
218.1
225.7
229.1
233.6
241.8
250.3
254.1
IC-2710H.qxd 02.2.8 16:55 Page 29 (1,1)
5
REPEATER OPERATION
30
Offset frequency
Push the desired bands tuning dial.
Select the mode/channel you wish to set the offset fre-
quency to, such as VFO mode or memory/call channel.
The offset frequency can be independently programmed into
each mode or channel.
Push [SET] one or more times until DUP appears and
ashes as shown above.
Pushing [MONI] reverses the order of selection.
Cancel the DTMF memory encoder or optional pager/code
squelch function in advance. (pgs. 49, 59, 62)
Rotate the selected bands tuning dial to set the desired
frequency.
Selectable step increment is the same as the preset tuning step.
(p. 18)
Use the selected bands [V/MHz] for quick MHz setting.
Push the selected bands tuning dial to exit set mode.
USING
SET MODE
Separate setting for each band
The display shows that a 0.6
MHz (600 kHz) frequency is
set.
DUP
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Set the mode/channel you wish to set the offset
frequency to, such as VFO mode or
memory/call channel.
The offset frequency can be independently pro-
grammed into each mode or channel.
Ç Push [FSET] one or more times until DUP ap-
pears and ashes as shown at left.
Pushing [GENT] reverses the order of selection.
Cancel the DTMF memory encoder or optional
pager/code squelch function in advance. (pgs. 49,
59, 62)
É Push [Y] or [Z] to select and set the desired
frequency.
Selectable step increment is the same as the preset
tuning step. (p. 18)
Pushing and holding [Y] or [Z] changes the fre-
quency continuously.
Ñ Push [ECLR] to exit set mode.
NOTE: The offset frequency can be set in a memory chan-
nel temporarily. However, the set contents are cleared
once the memory/call mode is selected. To store the offset
frequency permanently, overwrite the channel information.
SET
B
IC-2710H.qxd 02.2.8 16:55 Page 30 (1,1)
5
REPEATER OPERATION
31
Auto repeater
(U.S.A. version only)
The U.S.A. version automatically activates the repeater set-
tings (DUP or DUP and tone encoder ON/OFF) when the
operating frequency falls within the general repeater output
frequency range and deactivates them when outside of the
range.
D Setting the auto repeater function ON/OFF
Push [POWER] to turn power OFF.
While pushing [(VOL)
SET L] (left side), turn power ON to
enter initial set mode.
Push [SET L] one or more times until the rPt display ap-
pears as shown below.
Rotate the left-hand tuning dial to turn the auto repeater
function ON (rPt-r1 or rPt-r2) or OFF (rPt-oF).
•“rPt-r1 and rPt-r2 automatically set the duplex setting and du-
plex/tone encoder settings, respectively.
Push [POWER] momentarily to exit initial set mode.
USING
INITIAL SET MODE
Duplex setting:
Tone encoder:
Automatic ON
Automatic OFF
Automatic ON
Automatic ON
DUP
T
DUP
D Frequency range and offset direction
FREQUENCY RANGE DUPLEX DIRECTION
145.200145.495 MHz
146.610146.995 MHz
DUP–” appears
147.000147.395 MHz DUP appears
442.000444.995 MHz DUP appears
447.000449.995 MHz DUP–” appears
IC-2710H.qxd 02.2.8 16:55 Page 31 (1,1)
MEMORY OPERATION
6
32
General description
The transceiver has 99 regular memory channels plus 6 scan
edge memory channels (3 pairs) on each band; each of these
can be individually programmed with the following data.
Operating frequency (pgs. 1519)
Duplex direction (DUP or DUP) and its offset frequency
(pgs. 27, 30)
Subaudible tone encoder or tone squelch*
1
and its tone fre-
quency (pgs. 27, 29)
Skip information*
2
(p. 45)
*
1
An optional UT-104
TONE SQUELCH UNIT
is necessary.
*
2
Except for the scan edge memory channels.
Memory channel selection
D Using a tuning dial
Push the desired bands [M/CALL] once or twice to display
!.
Rotate the same bands tuning dial to select the desired
memory channel.
Only the programmed memory can be selected.
D Using [Y]/[Z] switches
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Push [MR] to select memory mode.
Ç Push [Y] or [Z] several times to select the de-
sired memory channel.
Pushing [Y]/[Z] more than 0.5 sec. activates a scan.
If a scan is activated, push [Y] or [Z] again to stop it.
D Using the keypad
Ä Push [BAND] to select the desired band, if necessary.
Å Push [MR] to select memory mode.
Ç Push [GENT] to activate the keypad for numeral input.
É Push 2 appropriate digit keys to input a channel
number.
When inputting non-programmed channel numbers
the previous memory channel appears.
To select scan edge channels, B and A can be
used for A and b respectively.
MR
Y/Z
MR
ENT
C
IC-2710H.qxd 02.2.8 16:55 Page 32 (1,1)
6
MEMORY OPERATION
33
Programming a memory channel
VFO mode settings, including the set mode contents such as
subaudible tone frequency, etc., are programmed into a mem-
ory channel.
Set the desired frequency in VFO mode:
Push the desired bands [V/MHz] to select VFO mode.
Set the frequency using the desired bands tuning dial.
Set other data (e.g. tone frequency, etc.) if required.
Push [S.MW] momentarily.
•“! and the memory channel number ashes.
Rotate the tuning dial to select the memory channel to be
programmed.
Memory channels not yet programmed are blank.
Push [S.MW] for 1 sec. to program.
3 beeps may sound.
Memory channel number automatically advances when continu-
ing to push [S.MW] after programming.
CONVENIENT
Memory programming can be performed in versatile ways
e.g. memory channel to the same (or different) memory chan-
nel, memory channel to the call channel, etc.
[EXAMPLE]: Programming 145.870 MHz into memory channel 20 via the remote controller.
159
159159
S.MW MW
Push and Rotate for setting
freq., etc.
Rotate
Push
momentarily
S.MW MW
Push
for 1 sec. and continue pushing
V/MHz
SCAN
IC-2710H.qxd 02.2.8 16:55 Page 33 (1,1)
6
MEMORY OPERATION
34
Programming a memory channel via the microphone
Memory channel programming can be performed
via the microphone.
Ä Push [BAND] to select the desired band, if necessary.
Å Set the desired frequency in VFO mode:
Push [VFO] to select VFO mode.
Set the frequency using the keypad.
Set other data (e.g. offset frequency, duplex direction, subaudi-
ble tone encoder ON/OFF and its frequency), if required.
MW
Ç Push [FUNC] then [EMW] momentarily.
É Select the memory channel to be programmed:
Push [Y] or [Z] to select the memory channel (direct numeral
input cannot be used).
Ñ Push [FUNC] then [EMW] for 1 sec. to program.
3 beeps may sound and the VFO contents (including the sub-
audible tone frequency, etc.) are programmed.
Memory channel number advances when continuing to push
[MW] after programming.
[EXAMPLE]: Programming 145.870 MHz into memory channel 20 via the microphone.
159
159159
Push , Push then
momentarily
PushPush for 1 sec. and
continue pushing
BAND VFO
8
DUP+
7
DUP
5
MID
1
MONI
4
HIGH
C
ENT
MW
FUNC
A
CLR
then
MW
FUNC A
CLR
IC-2710H.qxd 02.2.8 16:55 Page 34 (1,1)
6
MEMORY OPERATION
35
Transferring memory
contents
This function transfers a memory channels contents into a VFO
(or another memory/call channel). This is useful when search-
ing for signals around a memory channel frequency and for re-
calling the offset frequency, subaudible tone frequency, etc.
Push the desired bands tuning dial.
Select the memory channel to be transferred:
Select memory mode by pushing the selected bands [M/CALL]
once or twice (! appears).
Rotate the selected bands tuning dial to select the memory
channel.
Push [S.MW] momentarily, then rotate the tuning dial to se-
lect another memory channel to transfer.
To transfer to the VFO, push and hold [
(S.MW)MW] instead of
pushing momentarily.
Push and hold [(S.MW)MW] to transfer when a momentary
push was used in the previous step.
DUP
T
DUP
T
S.MW MW
Push
+
for 1 sec.
MW
FUNC
A
CLR
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Select the memory channel to be transferred:
Push [MR] to select memory mode.
Push [Y] or [Z] to select the memory channel; or
push [GENT] then push the desired memory chan-
nel number (2 digits) to select the memory channel
directly.
Ç Push [FUNC] then [EMW] momentarily, then
push [Y] or [Z] to select another memory chan-
nel to transfer.
To transfer to the VFO, push [FUNC] then push and
hold [EMW] instead of pushing momentarily.
É Push [FUNC] then [EMW] for 1 sec. to transfer
when a momentary push was used in the pre-
vious step.
MW
IC-2710H.qxd 02.2.8 16:55 Page 35 (1,1)
Memory clearing
Contents of programmed memories can be cleared (blanked),
if desired.
Push [S.MW] momentarily.
Select the memory channel to be cleared with the tuning
dial.
Push [S.MW] briey, then a second time for 1 sec.
3 beeps sound, then the frequency is cleared.
•“! ashes continuously.
Scan edges and call channel cannot be cleared.
Push any switch to stop the ashing.
[EXAMPLE]: Clearing memory channel 20.
NOTE:
Be carefulthe contents of cleared memories CANNOT
be recalled.
Memory channel 0 and scan edge channels 1A/1b cannot be
cleared.
Memory clearing may not be performed from the
microphone.
6
MEMORY OPERATION
36
159
Push Rotate
momentarily
again for 1 sec.
S.MW MW
Push
briefly, then push
S.MW MW
S.MW MW
Push
IC-2710H.qxd 02.2.8 16:55 Page 36 (1,1)
CALL CHANNEL OPERATION
7
37
Calling up a call channel
Each band has an independent call channel to store a most-
often-used frequency for quick recall.
Push the desired bands [M/CALL] once or twice to display
a large C in the memory channel readout.
To transmit on the call channel, select the desired band as the
main band in advance.
Push the same bands [V/MHz] or [M/CALL] to exit the call
channel.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Push [(MR)CALL] for 1 sec. to select the call
channel.
Transferring call channel
contents
Push the desired bands tuning dial.
Select the call channel by pushing the selected bands
[M/CALL] once or twice.
A large C appears.
Push [S.MW] momentarily, then rotate the tuning dial to se-
lect another memory channel to transfer.
To transfer to the VFO, push and hold [(S.MW)MW] instead of
pushing momentarily.
Push and hold [(S.MW)MW] to transfer when a momentary
push was used in the previous step.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Push [(MR)CALL] for 1 sec. to select the call
channel.
Ç Push [FUNC], then [EMW] momentarily.
To transfer to the VFO, push [FUNC] then [EMW] in-
stead of pushing [EMW] momentarily.
É Push [FUNC] then [EMW] for 1 sec. to transfer
when momentarily pushing [EMW] in step .
Large C shows the call
channel is selected.
Small c shows VFO mode
was selected from the call
channel.
CALL
MW
A
IC-2710H.qxd 02.2.8 16:55 Page 37 (1,1)
7
CALL CHANNEL OPERATION
38
Programming a call channel
In addition to an operating frequency, duplex information and
subaudible tone information (tone encoder or tone squelch*
ON/OFF and its frequency) can be programmed into the call
channel.
*An optional UT-104 is necessary.
Push the desired bands tuning dial.
Select the call channel by pushing the selected bands
[M/CALL] once or twice. (A large C appears.)
Set the desired frequency in VFO mode:
Push [VFO] to select VFO mode.
Set the frequency using the keypad.
Set other data (e.g. offset frequency, duplex direction, subaudi-
ble tone encoder ON/OFF and its frequency), if required.
Push [(S.MW)MW] for 1 sec. to program.
[EXAMPLE]: Programming 145.120 MHz into the VHF call channel via the microphone.
CONVENIENT
The call channel can also be programmed from the VFO di-
rectly (similar to memory programming).
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Push [(MR)CALL] for 1 sec. to select the call
channel.
Ç Set the desired frequency in VFO mode:
Push [VFO] to select VFO mode.
Set the desired frequency using the keypad.
Set other data, if required.
É Push [FUNC] then [EMW] for 1 sec. to pro-
gram.
MW
A
BAND VFO
2
SCAN
5
MID
1
MONI
1
MONI
4
HIGH
C
ENT
MW
FUNC
A
CLR
CALL
MR
Call channel VFO mode then
for 1 sec.
for 1 sec.
Beep
Beep
Beep
IC-2710H.qxd 02.2.8 16:55 Page 38 (1,1)
SCRATCH PAD MEMORY
8
39
What is a scratch pad
memory?
During VFO operation, the transceiver automatically memo-
rizes operating frequency information, separate from regular
memory channels, when transmitting on a new frequency.
The 3 previously operated frequencies for each band can be
recalled.
NOTE: When memory mode is selected, the frequency is
not programmed into a scratch pad.
Calling up a scratch pad
memory
Select the call channel by pushing the desired bands
[M/CALL] once or twice. (A large C appears.)
To transmit on the scratch pad memory, select the desired band
as the main band in advance.
Rotate the selected bands tuning dial to select a scratch
pad memory.
Previously transmitted frequency and one of L1L3 appears.
When first applying power or after CPU resetting, scratch pad
memories contain no data and therefore cannot be accessed.
Push the selected bands [V/MHz] or [M/CALL] to exit the
scratch pad memory.
The 3rd scratch pad memory will be cleared when trans-
mitting on a new frequency. If the transmit frequency is
already stored in a scratch pad memory, the scratch pad
memory is not cleared but the order is changed.
When transmitting on a scratch pad memory, the scratch
pad memory becomes the 1st scratch pad memory and
the order is changed.
Newest
Oldest
The oldest written frequency is cleared.
Order is changed if
transmitting on this
channel.
DUP
DUP
IC-2710H.qxd 02.2.8 16:55 Page 39 (1,1)
8
SCRATCH PAD MEMORY
40
Push the desired bands tuning dial.
Select the call channel by pushing the selected bands
[M/CALL] once or twice.
A large C appears.
Rotate the selected bands tuning dial to select the desired
scratch pad memory.
One of L1”–“L3 appears.
Push [(S.MW)MW] momentarily.
“” ashes to indicate VFO as the transferring channel.
Rotate the tuning dial to select the desired memory chan-
nel if required.
Push and hold [(S.MW)MW] to transfer.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Push [(MR)CALL] for 1 sec. to select the call
channel.
Ç Push [Z] one or more times to select the de-
sired scratch pad memory.
É Push [FUNC] then [EMW] momentarily.
“” ashes to indicate VFO as the transferring
channel.
Ñ Push [Y] or [Z] to select the desired memory
channel if required.
Ö Push [FUNC] then [EMW] for 1 sec. to transfer.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Push and hold [(MR)CALL] to select the call
channel.
Ç Push [Z] one or more times to select a duplex
scratch pad memory.
Once entering a scratch pad memory, [Y] can also
be used for selection.
É Push [MR] or [VFO] to exit the scratch pad
memory.
Transferring scratch pad
memory contents
Transferring scratch pad memory contents to the VFO is done
similarly to transferring regular memory/call channel contents.
CALL
Push for 1 sec.
then
S.MW MW
MW
FUNC
A
CLR
MW
IC-2710H.qxd 02.2.8 16:55 Page 40 (1,1)
SCAN OPERATION
9
41
FULL SCAN (p. 42)
Repeatedly scans all fre-
quencies over the entire
band. Used as the sim-
plest scan without any pre-
liminary settings neces-
sary.
PROGRAMMED SCAN
(p. 42)
Repeatedly scans bet-
ween two user-
programmed frequencies.
Used for checking for fre-
quencies within a speci-
fied range such as repeat-
er output frequencies, etc.
3 pairs of scan edges are
available.
SCAN RESUME CONDITION
(p. 46)
5 resume conditions are
available: 3 timer scans,
pause scan and empty
scan. When receiving a
signal, pause scan paus-
es until the signal disap-
pears; timer scans pause
for 5, 10 or 15 sec. Empty
pause scan pauses until a
signal appears.
MEMORY SCAN (p. 42)
Repeatedly scans memo-
ry channels except for skip
channels. Used for often-
called channels and by-
passing normally busy
channels such as repeat-
er frequencies.
Band
edge
Band
edge
Scan
Jump
Band
edge
Band
edge
Scan
Jump
Scan edges
SKIP
SKIP
Mch 1 Mch 5
Mch 2 Mch 3 Mch 4
Mch 6
Mch 80
Mch 7
Pause
scan
Receiving
a signal
Timer
scan
Empty
pause
scan
Pausing
Pausing
2 sec.
2 sec.
Scan types
Scanning searches for transmitted signals automatically and
makes it easier to locate new stations for contact or listening
purposes.
Scanning with tone squelch:
When an optional tone squelch is in use, tone decode
scan acivates instead of the above scans. To activate the
above scans with the tone squelch function, push and hold
[Y] or [Z] on the microphone.
Each band has 3 scan types and 5 resume conditions to suit
your needs. Scans on both bands can be operated separately
or simultaneously.
IC-2710H.qxd 02.2.8 16:55 Page 41 (1,1)
Scan start/stop
D Pre-operation
Common setting: scan resume condition. (p. 46)
For programmed scan: program the scan edges. (p. 43)
For memory scan: program 2 or more memory chan-
nels; set memory skip settings, if de-
sired. (p. 45)
D Operation
Push the desired bands tuning dial.
Select VFO mode for full/programmed scan; or memory
mode for memory scan with the selected bands [V/MHz]
switch.
Set the selected bands squelch to the point where noise
is muted.
Push [(V/MHz)SCAN] for 1 sec. to start the scan.
When the optional tone squelch is in use, [(V/MHz)SCAN] starts
the tone scan.
To change the scanning direction, rotate the selected bands tun-
ing dial.
The memory channel readout indicates the scan type as follows:
9
SCAN OPERATION
42
To select the scan range while operating full/programmed
scan, push [SET] several times.
To stop the scan, push [
(VMHz)SCAN].
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Push [VFO] to select VFO mode for full/pro-
grammed scan; or push [MR] to select memory
mode for memory scan.
Ç Push [HYSQL] or [AZSQL] one or more times
to set the squelch just closed.
É Push [SCAN] to start the scan.
[Y]/[Z] also start the scan when pushed and held.
Ñ To select the scan range while operating
full/programmed scan, push [SET] several
times.
Ö To stop the scan push [ECLR].
SCAN
2
SET
B
During full scan
Push to select full scan
and scan edge
pairs in sequence.
SET L
During programmed scan
Indicates scan edge channels.
P1 stands for 1A/1b.
P1 to P3 are available when
they are programmed.
During memory scan
IC-2710H.qxd 02.2.8 16:55 Page 42 (1,1)
9
SCAN OPERATION
43
Programming scan edges
Scan edges can be programmed in the same manner as
memory channels. Scan edges are programmed into pairs of
scan edge channels, 1A/1b to 3A/3b, in memory channels.
Push the desired bands tuning dial.
Set the desired frequency in VFO mode:
Push the selected bands [V/MHz] to select VFO mode.
Set the frequency using the selected bands tuning dial.
Set other data (e.g. offset frequency, etc.) if required.
Push [S.MW] momentarily.
•“! and the memory channel number ashes.
[EXAMPLE]: Programming 145.30 MHz and 145.80 MHz for the VHF scan edges 1A and 1b.
159
159
S.MW MW
Push
VHF
tuning
dial.
then rotate
Rotate
Push
momentarily
S.MW MW
S.MW MW
Push
and hold
continue pushing
Program 1b in the same manner.
Rotate the tuning dial to select a scan edge channel (1A to
3A).
Push [(S.MW)MW] for 1 sec. to program.
3 beeps may sound and the frequency is programmed.
Scan edge 1b is automatically selected when continuing to push
[(S.MW)MW] after programming.
To program a frequency for the other pair of scan edges,
1b to 3b, repeat steps and .
If the same frequency is programmed into both scan edges, pro-
grammed scan will not function.
IC-2710H.qxd 02.2.8 16:55 Page 43 (1,1)
9
SCAN OPERATION
44
Programming scan edges via
the microphone
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Set the desired frequency in VFO mode:
Push [VFO] to select VFO mode.
Set the frequency using the keypad.
Ç Push [FUNC] then [EMW] momentarily.
É Push [Y] or [Z] to select scan edge channels.
Ñ Push [FUNC] then [EMW] for 1 sec. to pro-
gram.
[EXAMPLE]: Programming 145.30 MHz and 145.80 MHz for the VHF scan edges 1A and 1b.
159
159159
Push Push then
momentarily
Program 1b
in the same
manner.
PushPush for 1 sec. and
continue pushing
VFO
3
PRIO
0
VOL
5
MID
1
MONI
4
HIGH
C
A
ENT
MW
FUNC
A
CLR
then
MW
FUNC
CLR
Y
3 beeps may sound and the VFO contents (including the sub-
audible tone frequency, etc.) are programmed.
Memory channel number advances to the next scan edge chan-
nel (1b to 3b) when continuing to push [EMW] after program-
ming.
Ö To program a frequency for the other scan edge channel,
repeat steps Å
and Ñ.
MW
A
IC-2710H.qxd 02.2.8 16:55 Page 44 (1,1)
9
SCAN OPERATION
45
Skip channel setting
The memory skip function speeds up scanning by checking
only desired memory channels. Set the memory channels to
be skipped or scanned as follows.
Push the desired bands tuning dial.
Select the memory channel to program or to cancel the
skip function on:
Select memory mode by pushing the selected bands [M/CALL]
once or twice.
Rotate the selected bands tuning dial to select the memory
channel.
Push [SET] one or more times until CHS appears as
shown above.
Pushing [MONI] reverses the order of selection.
Rotate the selected bands tuning dial to turn the skip func-
tion ON or OFF on the selected channel.
•“~ appears : The memory channel is skipped during
(CHS-on) memory scan.
•“~ disappears : The memory channel is scanned during
(CHS-OFF) memory scan.
USING
SET MODE
Separate setting for each band
SKIP
The display shows that VHF
memory channel 10 is set as
a skip channel.
Push the selected bands tuning dial to exit set mode.
NOTE: Scan edge memory channels cannot be specied
as skip channels, however, they are skipped during mem-
ory scan anyway.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Select the memory channel to program or to
cancel the skip function on:
Select memory mode by pushing [MR].
Push [Y] or [Z] to select a memory channel.
Ç Push [FSET] one or more times until CHS ap-
pears as shown at left.
Pushing [GENT] reverses the order of selection
once entering set mode.
É Push [Y] or [Z] to set or cancel the skip infor-
mation.
See item at left for skip indicator details.
Ñ Push [ECLR] to exit set mode.
SET
B
IC-2710H.qxd 02.2.8 16:55 Page 45 (1,1)
9
SCAN OPERATION
46
Scan resume
condition
The scan resume condition can be selected as timer, pause
or empty pause scan. The empty pause scan is useful for
finding unused frequencies. The resume condition is also
used for priority watch. (p. 47)
Push the desired bands tuning dial.
Push [SET] one or more times until SCt or SCP appears
as shown above.
Pushing [MONI] reverses the order of selection.
Cancel the DTMF encoder or optional pager/code squelch in ad-
vance. (p. 49, 59, 62)
Separate setting for each band
The display shows that the
scan resumes 15 sec. after it
stops.
USING
SET MODE
Rotate the selected bands tuning dial to set the desired
timer.
•“SCt-15 : Scan pauses 15 sec. while receiving a signal.
•“SCt-10 : Scan pauses 10 sec. while receiving a signal.
•“SCt-5 : Scan pauses 5 sec. while receiving a signal.
•“SCP-2 : Scan pauses until the signal disappears and then re-
sumes 2 sec. thereafter.
•“SCt-EP : Scan pauses on a frequency that is not busy and re-
sumes 2 sec. after a signal appears.
Push the selected bands tuning dial to exit set mode.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Push [FSET] one or more times until SCt or
SCP appears as shown at left.
Pushing [GENT] reverses the order of selection
once entering set mode.
Cancel the DTMF memory encoder or pager/code
squelch in advance. (pgs. 49, 59, 62)
Ç Push [Y] or [Z] to select the scan resume con-
dition.
See item above for scan resume condition details.
É Push [ECLR] to exit set mode.
SET
B
IC-2710H.qxd 02.2.8 16:55 Page 46 (1,1)
PRIORITY WATCH
10
47
Priority watch types
Priority watch checks for signals on a memory or call chan-
nel every 5 sec. while operating on a VFO frequency. The
transceiver has 3 priority watch types to suit your needs. You
can transmit on the VFO frequency while the priority watch
operates.
The watch resumes according to the selected scan resume
condition. See p. 46 for details.
NOTE:
Priority watch cannot be started from a scratch pad
memory.
The DTMF memory encoder or optional pager/code
squelch are turned OFF when priority watch starts.
If the optional pocket beep function is activated, the
transceiver automatically selects the tone squelch func-
tion when priority watch starts.
When SCt-EP is selected for the scan resume condi-
tion, the priority watch pauses on a no-signal channel.
(p. 46)
MEMORY CHANNEL
WATCH (p. 48)
MEMORY SCAN WATCH
(p. 48)
CALL CHANNEL WATCH
(p. 48)
VFO
frequency
Memory
channel
5 sec.
125 msec.
VFO
frequency
Mch 1
Mch 0
Mch 2
Mch 49
5 sec.
125 msec.
SKIP
VFO
frequency
Call
channel
5 sec.
125 msec.
While operating on a VFO
frequency, priority watch
checks for a signal on the
selected memory channel
every 5 sec.
A memory channel with skip
information can be watched.
While operating on a VFO
frequency, priority watch
checks for signals on each
memory channel in se-
quence.
The memory skip function and
memory area setting are use-
ful to speed up the scan.
While operating on a VFO
frequency, priority watch
checks for a signal on the
call channel every 5 sec.
IC-2710H.qxd 02.2.8 16:55 Page 47 (1,1)
10
PRIORITY WATCH
48
Priority watch operation
Push the desired bands tuning dial.
Select VFO mode; then, set an operating frequency.
Set the watching channel(s).
For memory channel watch:
Select the desired memory channel.
For memory scan watch:
Select memory mode; then, push [
(V/MHz)SCAN] for 1 sec.
to start memory scan.
For call channel watch:
Select the call channel by pushing the selected bands
[M/CALL] once or twice.
Push the selected bands [
(M/CALL)PRIO] for 1 sec. to start
the watch.
The transceiver checks the memory or call channel frequency
every 5 sec.
The watch resumes according to the selected scan resume con-
dition. (p. 46)
While the watch is pausing, pushing the selected bands
[M/CALL] resumes the watch manually.
Push the selected bands [M/CALL] while the display
shows the VFO frequency to stop the watch.
PRIO
While pausing on the
memory or call chan-
nel, PRIO flashes.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Select VFO mode; then, set an operating fre-
quency.
Ç Set the watching channel(s).
For memory channel watch:
Push [MR] then [Y] or [Z] to select the desired
memory channel.
For memory scan watch:
Push [MR] then [SCAN] to start the memory
scan.
For call channel watch:
Push and hold [
(MR)CALL] to select the call
channel.
É Push [PRIO] to start the watch.
The transceiver checks the memory or call channel
frequency every 5 sec.
The watch resumes according to the selected scan
resume condition. (p. 46)
To resume the watch manually while pausing, push
[PRIO] or [ECLR].
Ñ To stop the watch, push [ECLR] once (or twice
while watch pauses).
PRIO
3
IC-2710H.qxd 02.2.8 16:55 Page 48 (1,1)
DTMF MEMORY ENCODER
11
49
Programming a DTMF code
DTMF codes are used for autopatching, accessing repeaters,
controlling other equipment, etc. The transceiver has 8 DTMF
memory channels (d1 d8) for storage of often-used DTMF
codes of up to 16 digits.
NOTE: DTMF memory channels are commonly used for
both bands. Therefore, programming each band is not
necessary.
Push [DTMF] once and d appears in place of the main
bands 100 MHz digit as shown below.
Push [(VOL)SET] to enter the programming condition.
Rotate the main bands tuning dial to select the desired
channel.
Push [SET] or [MONI] to select the cursor.
Rotate the main bands dial to select a digit.
•“E stands for M and F stands for #.
Repeat steps and until the last digit is entered.
The S/RF indicator shows the digit group. The indication in-
creases every 6 digits.
Select “–” to clear the remaining digits when programming over a
previously used memory channel.
Push the main bands tuning dial to exit the programming
condition.
Clearing the DTMF memory
contents
Push [DTMF] to turn the DTMF memory encoder ON.
Push [SET] to enter the programming condition.
Rotate the main bands tuning dial to select the desired
channel.
Push [SET L] (for VHF display) or [MONI] (for UHF display)
to activate the 1st digit.
Rotate the main bands tuning dial to select “–” and clear
the memory channel contents.
Push the main bands tuning dial to exit the programming
condition.
d appears in place of
the 100 MHz digit.
IC-2710H.qxd 02.2.8 16:55 Page 49 (1,1)
11
DTMF MEMORY ENCODER
50
Programming a DTMF code via the microphone
[EXAMPLE]: Programming 5428AB453 into DTMF memory channel d4.
DTMF codes can be directly programmed via the
keypad on the microphone. The contents can be
overwritten, but cannot be cleared via the micro-
phone. See the page at left for clearing the con-
tents.
Ä Push [FUNC] then [DTMF] to turn the DTMF memory
function ON.
•“d appears in place of the 100 MHz digit.
Å Push [FSET] to enter the programming condition.
Ç Push [Y] or [Z] to select the desired channel.
DTMF
6
É Push the desired digit keys.
When the first digit is input, previous memory contents are
cleared automatically.
•“E stands for M and F stands for #.
Push [Y] then [Z], and repeat this step when making a mistake.
The S/RF indicator shows the digit group. The indication in-
creases every 6 digits.
Ñ Push the [BAND] to exit the programming condition.
The [ECLR] key cannot be used to exit. If pushed, A is input,
and the previously programmed data is erased. Reprogram again
in such a case.
Push
8
DUP+
5
MID
5
MID
4
HIGH
4
HIGH
A
CLR
then
FUNC
DTMF
6
LOW
B
SET
B
SET
2
SCAN
3
PRIO
BAND
IC-2710H.qxd 02.2.8 16:55 Page 50 (1,1)
11
DTMF MEMORY ENCODER
51
Transmitting a DTMF code
D Using the DTMF memory function
(automatic transmission)
The selected DTMF code is transmitted at each push of the
PTT switch when the DTMF memory encoder is turned ON.
Push [DTMF] to turn the DTMF memory encoder ON.
•“d appears in place of the main bands 100 MHz digit.
Push [SET] to enter the programming condition.
Rotate the main bands tuning dial to select the desired
DTMF memory channel.
Push [PTT] to transmit the selected DTMF code.
At each push of [PTT], the selected DTMF code is transmitted.
The speaker emits the DTMF tones sent.
Push [DTMF] to cancel the function.
•“d disappears.
When an optional UT-49 is installed, push [DTMF] several times until
a number appears for the 100 MHz digit and REMO disappears.
Ä Push [FUNC] then [DTMF] to turn the DTMF
memory encoder ON.
•“d appears in place of the main bands 100 MHz
digit.
Å Push [FSET] to enter the programming condi-
tion.
Ç Push [Y] or [Z] to select the desired channel.
DTMF
6
É Push [PTT] to transmit the selected DTMF code.
At each push of [PTT], the selected DTMF code is transmitted.
Ñ Push [ECLR] to cancel the function.
D Transmitting a DTMF memory channel directly
Ä Push [FUNC] then [DTMF] to turn the DTMF
memory encoder ON.
•“d appears in place of the main bands 100 MHz
digit.
Å Push [DTMF-S], then push the desired DTMF
channel number.
•“1 to 8 are available for channel numbers.
Ç Push [DTMF-S] again to deactivate the DTMF
setting.
É Push [ECLR] to turn the DTMF memory en-
coder OFF.
When the DTMF memory encoder is turned ON con-
tinuously, each push of the PTT transmits the previ-
ously selected DTMF code.
DTMF-S
IC-2710H.qxd 02.2.8 16:55 Page 51 (1,1)
11
DTMF MEMORY ENCODER
52
DTMF speed
The rate at which DTMF memories send individual DTMF
characters can be set to accommodate operating needs. This
setting does not affect an optional pager or code squelch op-
eration.
Push [POWER] to turn power OFF.
While pushing [(VOL)SET L] (left side), push [POWER] for
1 sec. to turn power ON and enter initial set mode.
Push [(VOL)SET L] or [(SQL)MONI] to select the dtd dis-
play as shown above.
Rotate the main bands tuning dial to select the desired
speed as shown in the table at right.
Push [POWER] momentarily to exit initial set mode.
USING
INITIAL SET MODE
Common setting for each band
The display shows the fas-
test DTMF speed is selected.
DISPLAY INTERVAL SPEED
dtd-1 100 msec. 5.0 cps
dtd-2 200 msec. 2.5 cps
dtd-3 300 msec. 1.6 cps
dtd-5 500 msec. 1.0 cps
cps=
characters/second
IC-2710H.qxd 02.2.8 16:55 Page 52 (1,1)
POCKET BEEP AND TONE SQUELCH
12
53
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Set the operating frequency.
Ç Program the subaudible tone frequency in set
mode.
See p. 29 for programming details.
É Push [FUNC] then [T SQLS] to turn the
pocket beep ON.
Turn OFF the pager or code squelch to activate the
pocket beep. (pgs. 59, 62) The pocket beep cannot
be used with the pager or code squelch.
Ñ When a signal with the correct tone is received,
the transceiver emits beep tones for 30 sec.
and ashes S.
Ö Push [PTT] to answer or push [ECLR] to stop
the beeps and ashing.
Tone squelch is automatically selected.
Pushing [FUNC] then [TSQL] also selects the tone
squelch.
Ü To cancel the function, push [FUNC] then
[GT-OFF].
D Waiting for a call from a specic station
A subaudible tone matched with the stations frequency is
necessary. Use the tone squelch on the next page or a sub-
audible tone encoder (p. 29).
Pocket beep operation
This function uses subaudible tones for calling and can be
used as a common pager to inform you that someone has
called while you were away from the transceiver.
To operate the pocket beep function, an optional UT-104 is
necessary. See p. 65 for installation details.
D Waiting for a call from a specic station
Push the desired bands tuning dial.
Set the operating frequency.
Program the subaudible tone frequency in set mode.
See p. 29 for programming details.
Push [(DTMF)T] for 1 sec., 2 times to indicate T SQLS
in the function display.
Turn OFF the pager or code squelch to activate the pocket beep.
(pgs. 59, 62) The pocket beep cannot be used in combination
with the pager or code squelch.
When a signal with the correct tone is received, the trans-
ceiver emits beep tones and ashes S.
Beep tones sound for 30 sec. To stop the beeps manually, push
the tuning dial (or any key).
•“S ashes coninuously until step or .
When receiving another call while S is ashing, no beeps sound.
Push [PTT] to answer.
Tone squelch is automatically selected when transmitting.
Push [(DTMF)T] for 1 sec. once or twice to cancel the function.
T SQLS
8
T-OFF
C
optional UT-104
IC-2710H.qxd 02.2.8 16:55 Page 53 (1,1)
12
POCKET BEEP AND TONE SQUELCH
54
Tone squelch operation
The tone squelch opens only when receiving a signal with the
same pre-programmed subaudible tone. This function can be
activated on both bands with separate tone frequencies si-
multaneously. To operate the tone squelch function, an op-
tional UT-104 is necessary.
Push the desired bands tuning dial.
Set the operating frequency.
Program the subaudible tone frequency in set mode.
See p. 29 for programming details.
Push [(DTMF)
T] for 1 sec., several times until T SQL ap-
pears in the function display.
The pager or code squelch can be used together with the tone
squelch. (p. 62)
When the received signal includes the correct tone, the
squelch opens and the signal can be heard.
When the received signal includes an incorrect tone, the squelch
does not open. However, the S/RF indicator shows the received
signal strength.
To open the accessed bands squelch manually, push the ac-
cessed bands [MONI].
Operate the transceiver in the normal way (push [PTT] to
transmit; release [PTT] to receive).
To cancel the tone squelch, push [(DTMF)T] for 1 sec.
•“T SQL disappears from the function display.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Set the operating frequency.
Ç Program the subaudible tone frequency in set
mode.
See p. 29 for programming details.
É Push [FUNC] then [T SQL] to turn the tone
squelch ON.
The pager or code squelch can be used with the
tone squelch. (p. 62)
Ñ When the received signal includes the correct
tone, the squelch opens and the signal can be
heard.
When the received signal includes and incorrect
tone, the squelch does not open. However, the S/RF
indicator shows the received signal strength.
To open the accessed bands squelch manually,
push [MONI].
Ö Operate the transceiver in the normal way
(push [PTT] to transmit; release [PTT] to re-
ceive).
Ü To cancel the tone squelch, push [FUNC] then
[GT-OFF].
T SQL
9
T-OFF
C
IC-2710H.qxd 02.2.8 16:55 Page 54 (1,1)
12
POCKET BEEP AND TONE SQUELCH
55
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Set the desired frequency to be checked for a
tone frequency e.g. repeater input frequency.
Ç Push [FUNC] then [T SQL] to turn the tone
squelch ON.
É Push [SCAN] to start the tone scan.
Ñ When the tone frequency is matched, the
squelch opens and the tone frequency is pro-
grammed into the selected mode such as VFO,
memory/call channel or scratch pad memory.
Ö Push [ECLR] to stop the scan.
Ü Push [FUNC] then [GT-OFF] to deactivate the
tone squelch or push [FUNC] then [TONE] to
activate the tone encoder with the detected
tone frequency.
NOTE: The decoded tone frequency is programmed tem-
porarily when a memory or call channel is selected.
However, this will be cleared when overwriting the mem-
ory/call channel.
Tone scan
By monitoring a signal that is being transmitted on a repeater
input frequency, you can determine the tone frequency nec-
essary to open a repeater.
An optional UT-104 is required to activate the tone scan.
Push the desired bands tuning dial.
Set the desired frequency to be checked for a tone fre-
quency e.g. repeater input frequency.
Push [(DTMF)T] for 1 sec., 3 times to display T SQL.
Push [(V/MHz)SCAN] for 1 sec. to start the tone scan.
To change the scanning direction, rotate the selected bands tun-
ing dial.
When the tone frequency is matched, the squelch opens
and the tone frequency is programmed into the selected
mode such as VFO, memory/call channel or scratch pad
memory.
Push [(V/MHz)SCAN] to stop the scan.
Push [(DTMF)T] for 1 sec. to deactivate the tone squelch or
twice to activate the tone encoder with the detected tone
frequency.
DUP
T SQL
T SQL
9
IC-2710H.qxd 02.2.8 16:55 Page 55 (1,1)
PAGER AND CODE SQUELCH
13
56
Pager function
The pager functions can be used only when an optional
UT-49 is installed. This function uses DTMF codes for paging
and can be used as a message pager to inform you of a
callers identity even if you leave the transceiver temporarily
unattended.
Personal calls and group calls are available with the pager
function. Personal calls use the receiving parties ID code for
calling. The receiving parties display shows your ID code and
other stations in the party know that you called.
Group calls use the group code for calling. All station displays
show the group code and all stations know that someone in
your group called.
To use the pager function in your group, all stations need the
pager function.
No answer back
Answer
back
No pager
111
333/555
222/555
111/555
beep
beep
No answer back
Answer
back
No pager
555
333/555
222/555
111/555
beep
beep
beep
beep
beep
beep
PAGER SIMULATION: Personal call PAGER SIMULATION: Group call
optional UT-49
IC-2710H.qxd 02.2.8 16:55 Page 56 (1,1)
13
PAGER AND CODE SQUELCH
57
Code channels
D Before programming
The pager and code squelch functions require ID codes and a
group code. These codes are 3-digit DTMF codes and must
be written in the code channels before operation. The trans-
ceiver has separate code channels for each band.
D Code channel assignment
* Code channel P automatically memorizes an ID code when receiv-
ing a pager call. The contents in channel P cannot be changed
manually.
ID OR
GROUP CODE
CODE CHANNEL
NUMBER
RECEIVE ACCEPT
OR RECEIVE INHIBIT
Your ID code 0 Receive accept only.
Other parties
ID code
15
Receive inhibit should
be programmed in each
channel.
Group code One of 15
Receive accept must be
programmed.
Memory space* P Receive inhibit only.
RECEIVE ACCEPT AND INHIBIT
Code channels 15 can store the transmit codes for per-
sonal calls to other individuals and the group codes for
group calls.
The group codes should be programmed as receive ac-
cept (“” disappears) to receive all calls from group
members.
If transmit codes are not programmed as receive inhibit,
the transceiver accepts calls directed to other individuals
and your answer back may confuse other members in your
groupthis is not a selective calling system. Therefore,
transmit codes should be programmed as receive inhibit
(“” appears) so the transceiver rejects calls directed to
other individuals.
SKIP
SKIP
IC-2710H.qxd 02.2.8 16:55 Page 57 (1,1)
13
PAGER AND CODE SQUELCH
58
Code programming
Push the desired bands tuning dial.
Each band has separate code channels.
Push [DTMF] 2 times to turn the pager function ON.
•“P appears in place of the 100 MHz digit.
Push [(VOL)SET] to select the code channel setting display.
Rotate the selected bands tuning dial to select the desired
code channel, 05.
Code channel P cannot be used for programming.
Push [(SQL)MONI] or [(VOL)SET] to select the digit to be
programmed.
Rotate the selected bands tuning dial to set the digit.
Repeat and until the last digit is programmed.
Push [DTMF] to set the code channel for receive inhibit
or receive accept.
When receive inhibit is set, “” appears.
Code channel 0 cannot be set as receive inhibit.
See p. 57 for receive inhibit or receive accept details.
Push the selected bands tuning dial to exit the setting dis-
play.
SKIP
159
The display shows that
VHF code channel 0
(your ID code) is pro-
grammed for 248.
Ä Push [BAND] to select the desired band, if nec-
essary.
Each band has separate code channels.
Å Push [FUNC] then [PGR] to turn the pager
function ON.
•“P appears in place of the 100 MHz digit.
Ç Push [FSET] to select the code channel setting
display.
É Push [Y] or [Z] to select and set the desired
code channel, 05.
Code channel P cannot be used for programming.
Ñ Push the numeral keys to enter the desired
3-digit code.
Digits are automatically stored once the 3rd digit has
been entered.
Ö Push [FSET] to set the code channel for re-
ceive inhibit or receive accept.
When receive inhibit is set, “” appears.
Code channel 0 cannot be set as receive inhibit.
See p. 57 for receive inhibit or receive accept de-
tails.
Ü Push [ECLR] to exit the setting display.
SKIP
SET
B
IC-2710H.qxd 02.2.8 16:55 Page 58 (1,1)
13
PAGER AND CODE SQUELCH
59
Pager operation
D Calling a specic station
Push the desired bands tuning dial.
Set the operating frequency.
Push [DTMF] 2 times to turn the pager function ON.
•“P appears in place of the 100 MHz digit.
An optional tone squelch can be used together with the pager
function, although the pocket beep cannot be used. (p. 54)
Select the desired code channel:
Push [SET].
Rotate the selected bands tuning dial to select the code chan-
nel.
Push the selected bands tuning dial to exit the setting display.
Push [PTT] to transmit the pager code.
Wait for an answer back.
When the transceiver receives an answer back code, the func-
tion display shows the other parties ID or group code and beeps.
(p. 60)
After confirming a connection, push the selected bands
tuning dial to display the operating frequency.
DO NOT push numeral keys on the microphone while a 3-digit
code is indicated, or code channel contents are changed.
Push [DTMF] once to select code squelch or 2 times (or 3
times for U.S.A. version) to select the non-selective calling
system.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Set the operating frequency.
Ç Push [FUNC] then push [PGR] to turn the
pager function ON.
•“P appears in place of the 100 MHz digit.
An optional tone squelch can be used together with
the pager function. (p. 54)
É Select the desired code channel:
Push [FSET].
Push [Y] or [Z] to select the code channel.
Push [ECLR] to exit the setting display.
Ñ Push [PTT] to transmit the pager code.
Ö Wait for an answer back.
When the transceiver receives an answer back
code, the function display shows the other parties
ID or group code and beeps. (p. 60)
Ü After conrming a connection, push [ECLR] to
display the operating frequency.
DO NOT push numeral keys on the microphone
while a 3-digit code is indicated, or code channel
contents are changed.
á Push [FUNC] then [C SQL] to select code
squelch or push [ECLR] to select the non-se-
lective calling system.
Pushing [FUNC] then [FD-OFF] also selects the
non-selective calling system.
PGR
4
IC-2710H.qxd 02.2.8 16:55 Page 59 (1,1)
13
PAGER AND CODE SQUELCH
60
D Waiting for a call from a specic station
Push the desired bands tuning dial.
Set the operating frequency.
Push [DTMF] to turn the pager function ON.
•“P appears in place of the 100 MHz digit.
An optional tone squelch can be used together with the pager
function, although the pocket beep cannot be used. (p. 54)
Wait for a call.
When receiving a call, the other parties ID or group code ap-
pears; S and the channel number blink as shown on the next
page.
DO NOT push numeral keys on the microphone while a 3-digit
code is indicated, or code channel contents are changed.
Push [PTT] to send an answer back call and display the
operating frequency.
Push [DTMF] once to select the code squelch system or 2
times (or 3 times for U.S.A. version) to select the non-se-
lective calling system.
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Set the operating frequency.
Ç Push [FUNC] then [PGR] to turn the pager
function ON.
•“P appears in place of the 100 MHz digit.
An optional tone squelch can be used together with
the pager function. (p. 54)
É Wait for a call.
When receiving a call, the other parties ID or group
code appears; S and the channel number blink
as shown on the next page.
DO NOT push numeral keys on the microphone
while a 3-digit code is indicated, or code channel
contents are changed.
Ñ Push [PTT] to send an answer back call and
display the operating frequency.
Ö Push [FUNC] then [C SQL] to select code
squelch or push [ECLR] to select the non-se-
lective calling system.
Pushing [FUNC] then [FD-OFF] also selects the
non-selective calling system.
PGR
4
IC-2710H.qxd 02.2.8 16:55 Page 60 (1,1)
13
PAGER AND CODE SQUELCH
61
Code squelch function
The code squelch function can be used only when an optional
UT-49 is installed.
Code squelch operation provides communication with silent
standby since you only receive calls from stations which know
your ID or group code. To use the code squelch function in
your group, all stations need the code squelch function.
The code squelch function transmits a 3-digit code prior to
voice transmission in order to open the receiving stations
code squelch.
PERSONAL CALLS
This display appears when
you are called with your ID
code and the calling stations
ID code is 263.
GROUP CALLS
This display appears when
you are called with the group
code, 123, and 123 has been
programmed into code chan-
nel 5.
ERROR INFORMATION
When the transceiver receives
an incomplete signal, E ap-
pears.
SKIP
159
159
SKIP
159
E appears
CODE SQUELCH SIMULATION:
No code squelch
function
111
111/555
000/555
000
IC-2710H.qxd 02.2.8 16:55 Page 61 (1,1)
13
PAGER AND CODE SQUELCH
62
Ä Push [BAND] to select the desired band, if nec-
essary.
Å Set the operating frequency.
Ç Push [FUNC] then [C SQL] to turn the code
squelch ON.
•“C appears in place of the 100 MHz digit.
An optional tone squelch can be used together with
the code squelch. (p. 54)
É Select the desired code channel:
Push [FSET].
Push [Y] or [Z] to select the code channel.
Push [ECLR] to exit the setting display.
Ñ Operate the transceiver in the normal way
(push [PTT] to transmit; release [PTT] to re-
ceive).
Prior to voice transmission, a 3-digit transmit code
is sent each time [PTT] is pushed in order to open
the receiving stations code squelch.
Ö To cancel the code squelch push [ECLR].
Pushing [FUNC] then [FD-OFF] also cancels the
code squelch.
Code squelch operation
Push the desired bands tuning dial.
Set the operating frequency.
Push [DTMF] 3 times to turn the code squelch ON.
•“C appears in place of the 100 MHz digit as shown below.
An optional tone squelch can be used together with the code
squelch, although the pocket beep cannot be used. (p. 54)
Select the desired code channel:
Push [SET].
Rotate the selected bands tuning dial to select the code chan-
nel.
Push the selected bands tuning dial to exit the setting display.
Operate the transceiver in the normal way (push [PTT] to
transmit; release [PTT] to receive).
Prior to voice transmission, a 3-digit transmit code is sent each
time [PTT] is pushed in order to open the receiving stations code
squelch.
To cancel the code squelch, push [DTMF] once (or 2 times
for the U.S.A. version).
The display shows the operating frequency.
C appears in place
of the 100 MHz digit.
C SQL
5
CLR
A
IC-2710H.qxd 02.2.8 16:55 Page 62 (1,1)
EXTERNAL DTMF REMOTE (U.S.A. version only)
14
63
When installing the optional UT-49
DTMF DECODER UNIT
, the
U.S.A. version can be remotely controlled using DTMF sig-
nals on the sub band. To operate external DTMF remote, a
144 MHz or 430(440) MHz transceiver with a DTMF encoder
is required.
Set the sub band frequency to receive a control signal
(DTMF code).
The optional tone squelch function can be used for the sub band
to increase remote control reliability. (p. 54)
Program a 3-digit password into the sub bands code chan-
nel 5, if desired. (p. 58)
The initial value of code channel 5 is 000; receive accept. If you
do not require the password, set the channel as receive inhibit.
Select the main band by pushing a tuning dial, then set the
desired frequency for operation.
Push [DTMF] one or more times until REMO appears to
select standby for the remote control.
Set the operating frequency of the controller transceiver
equal to the sub band frequency of the IC-2710H.
Make sure a tone frequency is set when using the optional tone
squelch function with the IC-2710H.
The external DTMF remote does not accept a control signal on
the main band frequency.
From the controller transceiver, transmit the DTMF code as
follows:
•“# and REMO ash while receiving a control signal.
To cancel standby for the remote control, push [DTMF].
•“REMO disappears.
Pushing [FUNC] then [FD-OFF] also cancels standby for the re-
mote control
Password
(if programmed)
(or
F)
(or
E)
Command
(See examples at right)
B # B
M
optional UT-49
IC-2710H.qxd 02.2.8 16:55 Page 63 (1,1)
14
EXTERNAL DTMF REMOTE
64
[ENT] 100
MHz
10
MHz
1 MHz 100
kHz
10 kHz
3D14 4
VFO
mode
144.750 MHz
CALL MR VFO CLR
[ENT]
2 digits
2D15
Memory
mode
Memory channel 15
Scratch pad
memory 2
7
1 2 3 A
HIGH
4 5 6 B
LOW1
7 8 9 C
UP ENTDOWN
M
0 # D
5
[EXAMPLE]
DTMF KEYPAD
[DOWN] [DOWN]
1
Call
channel
MM
[EXAMPLE]: Setting the operating frequency to 145.8125 MHz (when the VHF tuning step is 12.5 kHz).
Note for the [ENT] key
When the entered frequency is outside of the frequency coverage, the input
digits will be cleared.
To adjust the frequency less than 10 kHz or to select a scan edge memory
channel (1A, 1b), use the [UP] or [DOWN] key.
Password
(if programmed)
(or F) [ENT] (or E)(UP)
Frequency setting
B123 3# D 1458
VFO
mode
#
M
0 B
IC-2710H.qxd 02.2.8 16:55 Page 64 (1,1)
OPTIONAL UNIT INSTALLATION
15
65
Optional unit installation
There are 2 optional internal units available.
UT-49
DTMF DECODER UNIT
The following functions are added when the UT-49 is in-
stalled:
Pager function
Code squelch
External DTMF remote function (U.S.A. version only)
UT-104
TONE SQUELCH UNIT
The following functions are added when the UT-104 is in-
stalled:
Tone decode scan
Tone squelch (CTCSS tone decoder)
Pocket beep function
For installation of either unit, proceed as follows:
Turn power OFF then disconnect the DC power cable.
Set the transceiver upside down, then unscrew the one
screw from the bottom cover.
Open the bottom cover. (g. 1)
Use a at head screwdriver or similar at instrument to lever the
bottom cover open via the 2 openings towards the rear.
RWARNING! NEVER attempt to open the cover using your
nails, this may result in injury.
Plug the unit into the proper position as specified in the
above illustration. (g. 2, 3)
Replace the bottom cover and tighten the screw.
Bottom cover
fig. 1
fig. 2
fig. 3
Openings
UT-104
UT-49
IC-2710H.qxd 02.2.8 16:55 Page 65 (1,1)
WIRELESS OPERATION
16
66
Connection
Wireless remote control is available when the following op-
tions are used:
HM-90
WIRELESS MICROPHONE
EX-1759
INFRARED RECEIVER
The BC-96
MICROPHONE HOLDER
is additionally recommended
for use with the HM-90, since the HM-90s internal battery re-
quires charging.
D Recommended connection
HM-90
WIRELESS MICROPHONE
The HM-90s internal battery should be charged when the mi-
crophone is not being held.
Charging period: 1.5 hrs. with timer
(or 8 hrs. when battery is exhausted)
Operating period: 12 hrs (Operation : standby= 1 : 4)
D Charging method
Choose a method from one of the following:
Connect the cable from the HM-90 to the EX-1759.
Connect the BC-96 and EX-1759; then put the HM-90 into
the BC-96 (refer to the diagram at left).
Use the CP-1
CIGARETTE LIGHTER CABLE
to connect the
BC-96 and cigarette lighter socket.
D Turning the wireless remote ON/OFF
When you use the HM-90 as a wired microphone, turn OFF
the wireless remote control circuit if desired.
LOCK
AFC AFC-OFF PTT-M MW
PGR
CALL
123A
456B
MR VFO CLR
C-SQL DTMF D-OFF
HIGH MID LOW SET
The diagram shows that
the wireless remote con-
trol function is turned
ON.
Dip switch
1 2 3 4
ON
OFF
optional EX-1759 and HM-90
IC-2710H EX-1759
BC-96
Use the
microphones
cable
HM-90
IC-2710H.qxd 02.2.8 16:55 Page 66 (1,1)
16
WIRELESS OPERATION
67
EX-1759 installation
The EX-1759
INFRARED RECEIVER
can be installed for 2 differ-
ent purposes depending on the HM-90 charger. This is be-
cause the EX-1759 has both an infrared receiver and a
microphone connector which contains microphone charging
capabilities.
When using the BC-96 with external DC input
Attach the EX-1759 to a suitable location for receiving in-
frared signals, e.g. sunvisor, etc.
When using the connector for a microphone charger
Attach the EX-1759 to a suitable location for receiving in-
frared signals and where it can be connected to a cable, e.g.
the console, etc.
NOTE: DO NOT attach the EX-1759 where it will be sub-
ject to direct sunlight as it cannot detect infrared signals
under such conditions.
(When using BC-96
with external DC)
(When using the mic
connector for mic
charging.)
The installation clip can be oriented in 1 of 4 ways.
EX-1759
Optional infrared sub receiver
An optional EX-1513
INFRARED SUB RECEIVER
is available to
increase the remote control reliablility and extend the control-
lable area. Connect the EX-1513 to the inside connector of
the EX-1759.
NOTE: The supplied microphone, HM-98, can be con-
nected and used with the EX-1759, however, the optional
wireless microphone cannot be used in such a case.
IC-2710H.qxd 02.2.8 16:55 Page 67 (1,1)
16
WIRELESS OPERATION
68
HM-90 switches
PTT SWITCH
Push and hold to transmit; release to receive.
Toggles between transmitting and receiving while the
one-touch PTT function is in use.
BAND SWITCHES [BAND SELECT Y,Z]
Select the desired band as the main band.
Activate the para-watch function when pushed and held
when the main band is selected.
Activate the sub band access function after pushing
[FUNC] on the rear panel.
MONITOR SWITCH [MONI]
Toggles between opening and closing the accessed bands
squelch.
BAND
SELECT
MONI
REMOTE CONTROL MICROPHONE
VOLSQL
LOCK
JAPAN
AFC AFC-OFF PTT-M MW
PGR
CALL
123 A
456 B
M
0# D
MR VFO CLR
C-SQL DTMF D-OFF
SCAN
MONI
FUNC
DTMF
KEY
DTMF
MEMO
MUTE SQL ENT
789 C
DUP DUP
+
SIMP SPCH
PRIO REAR LOCK DEMO
TONE
HIGH MID LOW SET
T-SQLS T-SQL T-OFF
Front and side panels Rear panel
SQUELCH LEVEL UP/DOWN SWITCHES
[YSQL], [ZSQL]
Vary the accessed bands squelch threshold point for noise
mute.
FREQUENCY UP/DOWN SWITCHES [UP], [DN]
Push either switch to change the operating frequency,
memory channel, set mode contents, etc.
Push and hold either switch to start scanning.
ACTIVITY INDICATOR [UP], [DN]
Lights red while a key is pushed; lights green while the
one-touch PTT function is in use.
AUDIO VOLUME UP/DOWN SWITCHES
[YVOL], [ZVOL]
Adjust the accessed bands audio level.
MODE INDICATOR
Indicates the microphone condition.
Lights red when [FUNC] is pushed.
Lights green when [DTMF KEY] is pushed.
Lights orange when [DTMF MEMO] is pushed.
LOCK SWITCH [LOCK]
Locks all switches and keys on the microphone except for
the PTT switch.
KEYPAD
Used for controlling the transceiver, transmitting a DTMF
memory channel, etc.
IC-2710H.qxd 02.2.8 16:55 Page 68 (1,1)
16
WIRELESS OPERATION
69
D Keypad
KEY FUNCTION
SECONDARY FUNCTION (After )
FUNC
OTHER FUNCTIONS
Calls up a call channel. No secondary function.
After :
Input the appropriate digit
for frequency or memory
channel selection.
After :
Transmit the appropriate
DTMF code.
After :
Transmit the appropriate
DTMF memory contents.
[1] to [8] can be used for
DTMF memory.
DTMF
MEMO
DTMF
KEY
D
ENT
DEMO
Selects memory mode. No secondary function.
Selects VFO mode. Turns the one-touch PTT function ON
and OFF.
Selects high output power. Turns the optional pager function ON.
Selects mid output power. Turns the optional code squelch function
ON.
Selects low output power. Turns the DTMF memory function ON.
Selects duplex. Turns the subaudible tone encoder ON.
Selects + duplex. Turns the optional pocket beep function
ON.
Selects simplex. Turns the optional tone squelch function
ON.
Mutes both bands audio signals. Starts and stops a priority watch.
AFC
CALL
1
AFC-OFF
2
MR
PTT-M
3
VFO
PGR
4
HIGH
5
C-SQL
MID
6
DTMF
LOW
7
DUP
TONE
8
DUP
+
T-SQLS
9
SIMP
T-SQL
0
MUTE
PRIO
IC-2710H.qxd 02.2.8 16:55 Page 69 (1,1)
16
WIRELESS OPERATION
70
KEY FUNCTION
SECONDARY FUNCTION (After )
FUNC
OTHER FUNCTIONS
Clears a digit before entry.
Cancels the scan, priority watch, pager,
code squelch or DTMF memory function.
Writes the VFO contents into the memory
channel or call channel.
Advances the memory channel number
when continuously pushed after program-
ming is completed.
After :
Transmit the appropriate
DTMF code.
[
B
MONI]
Transmits a 1750 Hz tone
call signal for 1 sec.
[
A
SQL]
Transmits a 1750 Hz tone
call signal while pushing.
DTMF
KEY
Enters set mode and advances the set
mode selection order.
Turns the pager, code squelch, DTMF
memory or DTMF remote function OFF.
Decreases the set mode selection order
after entering set mode.
NOTE:
The IC-2710H has no voice synthesizer
function.
Turns the subaudible tone encoder, or op-
tional pocket beep/tone squelch OFF.
Sets the keypad for numeral input. Enters and exits demonstration mode.
Opens and closes the accessed bands
squelch.
Starts and stops scanning.
Starts tone scan while an optional tone
squelch is in use.
Selects 1 of the 4 preset squelch levels. Locks all the keys on the microphone key-
pad.
MW
A
CLR
B
D-OFF
SET
C
SPCH
T-OFF
D
ENT
DEMO
M
SCAN
MONI
#
SQL
REAR LOCK
IC-2710H.qxd 02.2.8 16:55 Page 70 (1,1)
16
WIRELESS OPERATION
71
Microphone
address
The transceiver has 8 possible microphone addresses to help
prevent interference from other HM-90
WIRELESS MICRO
-
PHONES
. Set both the microphone address and microphone
dip switch to the same value as follows.
NOTE: When the supplied microphone is connected, the
transceiver rejects control signals from the HM-90 even
when the microphone address is matched.
D Microphone address
Push [POWER] to turn power
OFF.
While pushing [(VOL)SET L],
turn power ON to enter initial
set mode.
Push [SET] a few times to se-
lect the Adr display as
shown at right.
Rotate the left-hand tuning dial to set the microphone ad-
dress to 07 or to turn the microphone control OFF.
When Adr-oF is selected, the transceiver rejects all control sig-
nals from the HM-90.
Turn power OFF to exit initial set mode.
USING
INITIAL SET MODE
The display shows the mi-
crophone address is set to 1.
D Microphone dip switch
Remove the switch cover from the microphone rear panel.
Set the microphone dip switch and the microphone ad-
dress to the same value as shown below.
Replace the switch cover.
MICROPHONE
ADDRESS
DIP SWITCH
S11 S12 S13
Adr-0 OFF OFF OFF
Adr-1 (default) ON OFF OFF
Adr-2 OFF ON OFF
Adr-3 ON ON OFF
Adr-4 OFF OFF ON
Adr-5 ON OFF ON
Adr-6 OFF ON ON
Adr-7 ON ON ON
LOCK
AFC AFC-OFF PTT-M MW
PGR
CALL
123A
456B
MR VFO CLR
C-SQL DTMF D-OFF
HIGH MID LOW SET
Dip switch
ON
OFF
1 2 3
(S1)
Switch cover
IC-2710H.qxd 02.2.8 16:55 Page 71 (1,1)
OTHER FUNCTIONS
17
72
Beep tones on/off
You can select silent operation by turning beep tones OFF or
you can select to have conrmation beeps sound at the push
of a switch by turning beep tones ON.
Push power to turn power OFF.
While pushing [(VOL)
SET L], turn power ON to enter initial
set mode.
Push [(VOL)
SET L] one or more times until bEP appears.
Pushing [(SQL)MONI] reverses the order of selection.
Rotate the left-hand tuning dial to select the condition.
•“bEP-oF: Beep tones are turned OFF.
•“bEP-on: Beep tones are turned ON.
Push [POWER] momentarily to exit initial set mode.
Time-out timer
To prevent accidental prolonged transmission with the one-
touch PTT function, etc., the transceiver has a time-out timer.
This timer cuts a transmission OFF after 3, 5, 15 or 30 min. of
continuous transmission. This timer can be cancelled (de-
fault).
Approx. 10 sec. before the time-out timer passes, the trans-
ceiver emits a beep tone as a warning.
Push [POWER] to turn power OFF.
While pushing [(VOL)SET L], turn power ON to enter initial
set mode.
Push [(VOL)SET L] one or more times until tot appears.
Pushing [
(SQL)MONI] reverses the order of selection.
Rotate the left-hand tuning dial to select the desired time-
out time or turn the timer OFF (oF).
Push [POWER] momentarily to exit initial set mode.
USING
INITIAL SET MODE
USING
INITIAL SET MODE
The display shows that beep
tones are turned ON.
The display shows that the 5
min. timer is selected.
TOT
The display shows that the
time-out timer is cancelled.
IC-2710H.qxd 02.2.8 16:55 Page 72 (1,1)
17
OTHER FUNCTIONS
73
Auto power-off
The auto power-off function conveniently turns the transceiver
power OFF after a preset time in which no operations are per-
formed. In this way, when you forget to turn the power OFF,
the transceiver automatically turns itself OFF, thereby con-
serving battery power.
The time can be set to 30 min., 1 hr., 2 hr. or turned OFF. The
selected time is retained even when the transceiver is turned
OFF via the auto power-off function. To cancel the function,
select oF in step below.
Push [POWER] to turn power
OFF.
While pushing [(VOL)SET L],
turn power ON to enter initial
set mode.
Push [(VOL)SET L] one or
more times until PoF appears.
Pushing [
(SQL)MONI] reverses the order of selection.
Rotate the left-hand tuning dial to select the desired auto
power-off time or turn the timer OFF (oF).
•“AO appears when an auto power-off time is set.
Push [POWER] momentarily to exit initial set mode.
Cooling fan
setting
The transceiver has a heatsink and cooling fan to radiate
heat. The cooling fan automatically turns ON while transmit-
ting and remains ON for 2 min. after transmitting. The cool-
ing fan can be activated continuously, if desired.
Push power to turn power OFF.
While pushing [(VOL)SET L], turn power ON to enter initial
set mode.
Push [(VOL)SET L] one or more times until FAn appears.
Pushing [
(SQL)MONI] reverses the order of selection.
Rotate the left-hand tuning dial to set the cooling fan to au-
tomatic (At) or continuous (on).
Push [POWER] momentarily to exit initial set mode.
USING
INITIAL SET MODE
USING
INITIAL SET MODE
The display shows that the
30 min. timer is selected.
AO
The display shows that the
cooling fan is set for au-
tomatic operation.
The display shows that the
cooling fan is set for contin-
uous operation.
IC-2710H.qxd 02.2.8 16:55 Page 73 (1,1)
17
OTHER FUNCTIONS
74
Microphone [F-1]/[F-2] keys
Switches on the transceivers front panel can be assigned to
the microphones [F-1] and [F-2] keys.
Turn power OFF.
While pushing the desired switch on the transceiver and
[F-1] or [F-2] on the microphone, turn power ON.
The switches function is programmed into the key ([F-1] or [F-2]).
Default setting
The following functions are assigned to the [F-1]/[F-2] keys
when rst applying power or after CPU resetting:
[F-1]: VHF band tuning dial switch
[F-2]: UHF band tuning dial switch
Display dimmer setting
Adjust the intensity intensity to suit lighting conditions and
personal preference.
Push and hold [VOL(SET)D] (right side) until d-1”–“d4 ap-
pears as shown below.
Rotate the tuning dial (right side) to set the desired inten-
sity.
Intensity can be set from d1 (dark) to d4 (bright).
Push [VOL(SET)
D] to return to normal operation.
Demonstration display
A demonstration function is available at power ON. This func-
tion gives you a quick visual introduction to the function dis-
play indicators.
While pushing either tuning dial, push [POWER] to turn
power ON.
The transceiver cycles through a visual tour of the function dis-
play indicators.
Push any switch to exit demonstration mode and enter the
normal operating condition temporarily.
NOTE: The transceiver automatically returns to demon-
stration mode after 2 min. in which no operations are per-
formed. To deactivate the demonstration display
permanently, perform step again.
9
IC-2710H.qxd 02.2.8 16:55 Page 74 (1,1)
MAINTENANCE
18
75
Troubleshooting
If your transceiver seems to be malfunctioning, please check
the following points before sending it to a service center.
PROBLEM POSSIBLE CAUSE SOLUTION REF.
No power comes on. Power connector has a poor contact.
Polarity of the power connection is reversed.
Blown fuse.
Check the connector pins.
Reconnect the power cable observing the proper
polarity. Replace the fuse, if damaged.
Check the cause, then replace the fuse.
pgs.
13, 77
p. 77
No sound comes from the
speaker.
Volume level is too low.
The squelch level is set too tight.
An optional selective call or squelch function is
activated such as tone squelch, pocket beep,
pager or code squelch.
Rotate [VOL] clockwise.
Set the squelch level to the threshold.
Turn the appropriate function OFF.
p. 20
p. 20
pgs.
53, 54,
59, 62
Sub band signals are not au-
dible.
The sub band mute function is activated. Turn the function OFF. p. 23
Sensitivity is low and only
strong signals are audible.
Antenna feedline or the antenna connector sol-
der has a poor contact or is short circuited.
Check, and if necessary, replace the feedline or
solder the antenna connector again.
p. 14
No contact possible with an-
other station.
The transceiver is set to semi-duplex.
The other station is using code or tone squelch.
Set to simplex.
Turn ON the optional code squelch (UT-49) or
optional tone squelch (UT-104 ).
p. 28
pgs.
62, 54
Repeater cannot be ac-
cessed.
Wrong offset frequency is programmed.
Wrong subaudible tone frequency is pro-
grammed.
Correct the offset frequency.
Correct the subaudible tone frequency.
p. 30
p. 29
Frequency cannot be set.
The frequency lock function is activated.
Priority watch is paused on the watching fre-
quency.
Turn the function OFF.
Push [(M/CALL)PRIO] to resume the watch.
p. 16
p. 48
IC-2710H.qxd 02.2.8 16:55 Page 75 (1,1)
18
MAINTENANCE
76
PROBLEM POSSIBLE CAUSE SOLUTION REF.
Frequency cannot be set via
microphone.
The frequency lock function is activated.
The microphone keypad lock function is acti-
vated.
Priority watch is paused on the watching fre-
quency.
Push and hold [
(VFO)
LOCK] to deactivate the
frequency lock function.
Push [FUNC], then [A16KEY LOCK] to deacti-
vate the microphone keypad lock function.
Push the selected bands [(M/CALL)PRIO] to re-
sume the watch.
p. 16
p. 16
p. 48
Some memory channels
cannot be selected via the
microphone keypad.
The input channel number has not yet been pro-
grammed.
Rotate the tuning dial to check whether the
channel has been programmed or not.
p. 32
Scan does not operate. Squelch is open.
The selected scan edge memory channels (e.g.
1 A and 1b) have the same frequencies (for pro-
grammed scan).
Only 1 memory channel is programmed or other
channels are set as skip channels.
Priority watch is activated.
Set the squelch to the threshold point.
Reset the scan edges.
Program other memory channels or cancel the
memory skip function in the desired channels.
Turn the function OFF.
p. 20
p. 43
pgs.
33, 45
p. 48
Transmission is automati-
cally cut off.
Time-out timer is activated. Set the timer to OFF. p. 72
Transmission continues
even when the PTT is re-
leased.
One-touch PTT function is activated. Turn the function OFF. p. 26
The function display shows
erroneous information.
The CPU is malfunctioning. Reset the transceiver.
p. 77
IC-2710H.qxd 02.2.8 16:55 Page 76 (1,1)
18
MAINTENANCE
77
Fuse replacement
If the fuse blows or the transceiver stops functioning, nd the
source of the problem if possible, and replace the damaged
fuse with a new, rated one (FGB 20 A) as shown in the dia-
gram below.
Partial resetting
If you want to initialize the operating conditions without clear-
ing the memory contents, etc., a partial reset function is avail-
able for the transceiver. The partial reset can be performed
independently for each band.
While pushing either left or right, or both [V/MHz] switches,
turn power ON to partially reset the transceiver.
Initialized settings: VFO frequency, SET mode settings.
Retained settings: Memory channels, call channels, offset
freq. in memory/call, DTMF memory,
pager and code squelch settings, initial
SET mode settings.
Resetting the transceiver
The function display may occasionally display erroneous in-
formation, (e.g. when first applying power). This may be
caused externally by static electricity or other factors.
If this problem occurs, turn power OFF. After waiting a few
seconds, turn power ON again. If the problem persists, per-
form the following procedure.
Partial resetting is alternatively available. See previous sec-
tion for details.
Push [POWER] to turn power OFF.
While pushing both left and right [S.MW] switches, turn
power ON.
All LCD segments appear momentarily, the initial display appears
and the transceiver is reset.
CAUTION: Resetting the transceiver CLEARS all
memory information, and initializes all values in the trans-
ceiver.
IC-2710H.qxd 02.2.8 16:55 Page 77 (1,1)
SPECIFICATIONS
19
78
General
Frequency coverage
VERSION VHF UHF
144148 MHz
440450 MHz
Asia
144148 MHz
430440 MHz
Europe 144146 MHz 430440 MHz
Italy
144146 MHz 430440 MHz
Tx
Rx
136174 MHz*
2
Tx
Rx
136174 MHz*
2
400479 MHz*
3
*
1
118136 MHz is usable in the VHF display only; guaranteed frequency cov-
erage is 144148 MHz.
*
2
Guaranteed frequency coverage is 144148 MHz.
*
3
Guaranteed frequency coverage is 430440 MHz.
Mode : FM, AM*
(*U.S.A. version only; 118136 MHz)
Antenna impedance : 50 (SO-239)
Power supply requirement : 13.8 V DC ± 15%
Usable temperature range : 10°C to +60°C; +14°F to +140°F
Dimensions : 140(W) x 40(H) x 212.4(D) mm
(projections not included) 5
1
2(W) x 1
9
16(H) x 8
3
8(D) in
Weight : 1.4 kg; 3.1 lb
Transmitter
Modulation system : Variable reactance frequency
modulation
Max. frequency deviation : ± 5.0 kHz
Spurious emissions : Less than 60 dB
Microphone impedance : 600 (8-pin modular)
Output power and current drain:
Receiver
Receive system : Double conversion superheterodyne
Intermediate frequencies :
Left display band 1st 45.05 MHz 2nd 455 kHz
Right display band 1st 57.65 MHz 2nd 455 kHz
Sensitivity (for 12 dB SINAD) : Less than 0.16 µV (incl. para watch)
Squelch sensitivity : Less than 0.13 µV
(at threshold)
Selectivity : More than 15 kHz/6 dB
Less than 30 kHz/60 dB
Spurious response : More than 60 dB
rejection ratio
Audio output power : More than 2.4 W at 10% distortion
with the 8 internal speaker
Current drain :
Max rated audio/both bands 1.8 A
Max audio/either band 1.5 A (squelch closed on other band)
Squelched on both bands 1.2 A
CONDITION POWER
144 MHz
50 W
10 W
5 W
430(440) MHz
12.0 A
6.5 A
4.5 A
11.0 A35 W
10 W 6.5 A
5 W 4.5 A
High
Low
Mid
High
Mid
Low
All stated specications are subject to change without notice or
obligation
CURRENT
U.S.A.
118174 MHz*
1
Rx
Tx
IC-2710H.qxd 02.2.8 16:55 Page 78 (1,1)
OPTIONS
20
79
Some of the following options may not be available due to
variations in local electrical standards, etc. If you have any
questions regarding options please consult your Icom Dealer.
D Antenna
AH-32 144/430(440) MHz DUAL BAND ANTENNA
Dual band mobile antenna.
Frequency range: 144148 MHz and 430450 MHz.
Max. input power: 150 W
AHB-32 TRUNK MOUNT
Trunk mount with a coaxial cable for the AH-32.
D Speakers
SP-7 EXTERNAL SPEAKER
For base station use. Cable length: 1.0 m; 3.3 ft
SP-10 EXTERNAL SPEAKER
Compact design. Cable length: 1.5 m; 4.9 ft
SP-12 EXTERNAL SPEAKER
Slim-type. Cable length: 2.0 m; 6.6 ft
D Separation accessories
OPC-600/601 SEPARATION CABLE
For operation with the front panel detached.
Cable length
OPC-600: 3.5 m; 11.5 ft OPC-601: 7.0 m; 23.0 ft
MB-58 REMOTE CONTROLLER BRACKET
Mounts the remote controller in a convenient location for op-
eration with the front panel detached from the main body.
MB-65 REMOTE CONTROLLER BRACKET
Mounts the remote controller with MB-58. Adjustable angle
and direction for optimum installation positioning.
OPC-440/647 MIC EXTENSION CABLE
Cable length
OPC-440: 5.0 m; 16.4 ft OPC-647: 2.5 m; 8.2 ft.
OPC-347 DC POWER CABLE
Has a 20 A capacity and a length of 7.0 m (23.0 ft).
OPC-441 SPEAKER EXTENSION CABLE
Cable length: 5.0 m; 16.4 ft.
SP-7 SP-10 SP-12
MB-65
IC-2710H.qxd 02.2.8 16:55 Page 79 (1,1)
20
OPTIONS
80
D Wireless microphone accessories
HM-90 WIRELESS MICROPHONE
Infrared, full remote control microphone. Wired remote con-
trol is also possible.
EX-1759 INFRARED RECEIVER
Used to receive control signals from the HM-90.
EX-1513 INFRARED SUB RECEIVER
Used with the EX-1759 to increase remote control reliability
and extend the controllable area.
BC-96 MICROPHONE HOLDER
Holds the HM-90 body in a convenient place and supplies
power to the charging circuit of the HM-90. Has a charging
indicator.
CP-13/L CIGARETTE LIGHTER CABLE WITH NOISE FILTER
OPC-288/L DC POWER CABLE
Supply power to the BC-96 for charging the Ni-Cd battery in-
side the HM-90 when the BC-96 cannot be connected to the
EX-1759 directly.
D Internal units for function enhancements
UT-49 DTMF DECODER UNIT
Provides pager and code squelch functions. Also provides an
external DTMF function for the U.S.A. version only.
UT-104 TONE SQUELCH UNIT
Provides pocket beep, tone squelch and tone scan functions.
D Others
MB-17A MOBILE MOUNTING BRACKET
One-touch bracket. Transceiver body is easily attached and
removed.
IC-PS30 DC POWER SUPPLY
Provides 13.8 V DC and 25 A max. for base station use.
CS-2710 CLONING SOFTWARE + OPC-646 CLONING CABLE
Provides quick and easy programming of items, including
memory channels and set mode contents, for local repeater
frequencies, etc.
HM-90
BC-96 MB-17A
IC-2710H.qxd 02.2.8 16:55 Page 80 (1,1)
MODE ARRANGEMENT
21
81
MEMORY MODE (p. 32)
VFO MODE (p. 15)
CALL CHANNEL (p. 37)
SCRATCH PAD
MEMORY (p. 39)
See p. 49 for details.
DTMF MEMORY
CODE CHANNEL
Used for programming
the code channel for
pager and code squelch
(p. 57).
M/CALL
V/MHz
SCAN
V/MHz
SCAN
SET L
or no operation
for 30 sec.
SEL L
*
1
Only appears
*
2
Only appears
When the DTMF
memory encoder is
activated.
When the pager or code squelch is in use.
M/CALL
Although the following chart refers mainly to the VHF band, the transceiver has the same
mode arrangement in the UHF band.
IC-2710H.qxd 02.2.8 16:55 Page 81 (1,1)
Y
CHANNEL
r programming
e channel for
d code squelch
INITIAL SET MODESET MODE
MONISEL L
SEL L
Sub band mute (p. 23)
SKIP
Skip channel*
2
setting (p. 45)
Beep tone on/off (p. 72)
Turn power ON while pushing [SET L].
Time-out timer (p. 72)
Auto power-off (p. 73)
DUP
T
Auto repeater* (p. 31)
* U.S.A. version only.
Cooling fan setting (p. 73)
Microphone address (p. 74)
MONI
DTMF speed (p. 52)
Offset frequency
(p. 30)
DUP
Scan resume
condition (p. 46)
Tuning step*
1
(p. 18)
Subaudible tone
frequency (p. 29)
T
*
1
Only appears when entering SET mode from VFO mode.
*
2
Only appears when entering SET mode from memory mode.
activated.
When the pager or code squelch is in use.
21
MODE ARRANGEMENT
82
IC-2710H.qxd 02.2.8 16:55 Page 82 (1,1)
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003 Japan
A-5382H-1EX
Printed in Japan
Copyright © 1996 by Icom Inc.
Count on us!
IC-2710H.qxd 02.2.8 16:55 Page 83 (1,1)
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-2710H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-2710H in the language / languages: English as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info