661332
28
Zoom out
Zoom in
Previous page
1/186
Next page
- 26 -
Outdoor board failure
module board failure between
outdoor board and module
board
EE10
Communication wire is broken
Outdoor board or module
board failure
Restart the power supply or
change the broken board
Module board failure
EE11
The data is wrong or the
module board is broken
Restart the power supply or
change the broken board
Direct main current’s voltage
too high or too low protection
EE12
The pressure is too high or too
low
The inner communication
contactor is broken
Check the power supply
Change the contactor
Over current protection
EE13
Electric supply pressure is too
low, the heat pump is overload
Check the power supply
Check the water temperature
whether it is too high
IPM module temperature
sensing circuit output
failure
EE14
IPM module temperature
sensor output is abnormal
Check the PC board or
replace the new one
IPM module temperature
too high protection
EE15
Check the PC board or
replace the new one
Malfunction
Error code
Reason
Solution
PFC module protection
EE16
Check the PC board or
replace the new one
DC fan failure
EE17
Check the PC board or
replace the new one
PFC module temperature
sensing internal circuit
failure
EE18
Check the PC board or
replace the new one
PFC module high
temperature protection
EE19
Check the PC board or
replace the new one
Input power failure
EE20
The supply voltage
fluctuates too much
Check the PC board or
replace the new one
Software control failure
EE21
Compressor runs out of step
Check the PC board or
replace the new one
Current detection circuit
failure
EE22
The amplifier output
voltage signal is abnormal
Check the PC board or
replace the new one
Compressor start failure
EE23
Check the PC board or
replace the new one
Driving board ambient
temperature bulb failure
EE24
Compressor phase failure
EE25
1. Wiring wrong
2. Connection of 1 phase or
2 phases.
Monitoring the controller
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hydro-Pro Inverter 13 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hydro-Pro Inverter 13 in the language / languages: English, German, Dutch, Danish, French, Polish as an attachment in your email.

The manual is 4,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info