Dimension Terminal Position Minimum
Distance
(mm)
A Directly below an openable window or other opening e.g. air brick 300
B Below gutters, soil pipes or drain pipes 300
C Below eaves 300
D Below balconies or car port roofs 600
E From vertical drain pipes and soil pipes 75
F From internal or external corners 600
G Above ground, roof or balcony level 300
H From a surface facing a terminal 600
I From a terminal discharging towards another terminal 600
J From an opening in a car port (e.g. door, window) into a dwelling 1200
K Vertically from a terminal on the same wall 1500
L Horizontally from a terminal on the same wall 300
Timber framed dwellings
When installing the fl ue in properties of timber framed construction, the regulations (BS 5440:
Part 1:1990) must be adhered to.
Post installation checks
Before leaving the appliance connected to the gas supply, the installer is required visually to
examine the appliance and fl ueway to ensure that:
a) The seal between the combustion chamber and the room is intact and in good condition.
b) The fl ue has been correctly sealed using the sealing tape as recommended.
c) There are no debris contained within the fl ue assembly.
d) The joint between the terminal and the wall is weatherproof.
e) All pipe work has been purged
Standard fl ue connection
The fl ue to which the appliance is to be attached must conform to BS 5440 1990:pt.1. Before the
appliance is installed, the fl ue system or chimney must be inspected and passed as suitable.
This stove is suitable for installation onto either fl exible or fabricated steel fl ue system and is also
suitable for pre-cast fl ues, pre-cast chimney block, pre-cast fl ue block and ridge tile vent.
The minimum effective height of the fl ue must be three metres measured from the hearth to the
termination of the fl ue. If the fl ue has any non-vertical sections, the height should be increased
in line with BS 5440 pt.1. Prior to installation, the installer should ensure that the fl ue is free from
obstruction, ideally should be swept and subsequently smoke tested. Ensure that any dampers
are fi xed in a permanently open position.
Sealing the fl ue joints
The fl ue joints must be weather sealed to prevent moisture entering the fl ue system. It is recom-
mended that the fl ue joints be sealed with a high temperature tape, such as aluminium tape.
Vent terminal
The vent terminal must be located in accordance with BS5440:Part 1:1990 for natural draught
Balanced Flue or Natural Draughts. This standard is summarised below (drawing E)
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam Figaro gas at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam Figaro gas in the language / languages: English, German, Danish, Swedish as an attachment in your email.

The manual is 0,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hwam Figaro gas

Hwam Figaro gas User Manual - Dutch, French, Italian - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info