1. The First Stoking
Open the door. Place two pieces of wood (5-8 cm in diameter) horizontally in the
bottom of the combustion compartment. Place 5-8 pieces of kindling randomly
on top. Place two firelighters in between the top layers of kindling. Light up the
firelighters and close the stove door. Set the temperature level to level 1. Let the
fire burn out and do not restoke even if there is a restoking alarm. When the fire
has died out completely, the door must be opened and stay open while the stove
cools down to room temperature.
2. The Second Stoking
Open the door. Place two pieces of wood (5-8 cm in diameter) horizontally in the bottom of the com-
bustion compartment. Place 5-8 pieces of kindling randomly on top. Place two firelighters in between
the top layers of kindling. Light up the fire-lighters and close the stove door. Set the temperature level
to level 2. When there is a restoking alarm, you should restoke. Put at least two pieces of wood into
the stove, weighing up to 1 kg each. Let the fire burn and let the stove cool down to room temperature
before the next lighting.
3. The Third Stoking
Repeat the second stoking. Set the temperature level to level 3. Let the fire burn and allow the stove to
cool down after the fire has died out.
Restoking:
Follow the general instructions, see the sections “Lighting up” and “Stoking”.
Lighting Up
A successful combustion process requires that the wood is lit in the right way. A cold stove and a cold
chimney challenge the combustion process. Be careful to make a good lighting with suitably dry wood,
using kindling and lighting the fire in the top layers of kindling. It is important to achieve a high flue gas
temperature quickly.
Open the door. Place two pieces of wood (5-8 cm in diameter) horizontally in the
bottom of the combustion compartment. Place 5-8 pieces of kindling randomly
on top. Place two fire-lighters in between the top layers of kindling. Light up the
fire-lighters and close the stove door. Select the desired room temperature level.
As soon as the door is opened the HWAM® SmartControlTM is activated. If lighting up does not occur
within 15 minutes, the HWAM® SmartControlTM will automatically go back to standby and the dampers
in the Air box will be closed.
If the smoke temperature does not reach a high enough level after lightning or stoking, the app IHS Smart
Control
TM
and the wireless room temperature sensor emit a restoking alarm, even if there is still unburned
wood and flames in the combustion chamber. The restoking alarm is emitted to make you aware that the
fire needs more energy. Restoking with small pieces of kindling wood can often provide a more rapid
and sufficient temperature rise.
The HWAM
®
SmartControl
TM
closes all three air dampers in the Air box when the stove is in standby mode.
This prevents hot air from the room to enter the chimney (heat loss). This might on the other hand result in a
very cold chimney when the stove is lit. In certain cases it is necessary to assist the draught in the chimney by
opening the door to the burning chamber 3-5 minutes before lightning the stove. Read more on www.hwam.com
about the function of the chimney.
Important!
The ash pit must not be opened when lighting up. It must always be closed when the stove is in use.
Otherwise the HWAM® SmartControlTM does not function. The door should only be opened when
lighting up, when restoking, and when cleaning the stove. Never leave a stove before there are lasting
flames in the wood after firing!
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam 3520 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam 3520 in the language / languages: English as an attachment in your email.

The manual is 1.57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hwam 3520

Hwam 3520 User Manual - English - 56 pages

Hwam 3520 User Manual - German - 44 pages

Hwam 3520 User Manual - Dutch - 32 pages

Hwam 3520 User Manual - Danish - 56 pages

Hwam 3520 User Manual - French - 32 pages

Hwam 3520 User Manual - Italian - 44 pages

Hwam 3520 User Manual - Swedish - 56 pages

Hwam 3520 User Manual - Spanish - 44 pages

Hwam 3520 User Manual - Norwegian - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info