RST
24VAC
BAT
Valve Common Wire
Connect the Two
Transformer Wires to
the Two AC Terminals
Valve 1
Valve 2
Valve 3
Valve 4
Valve
Wires
3
MOUNTING THE CONTROLLER TO WALL
NOTE: The indoor XC is not waterproof or weather resis-
tant, and must be installed indoors or in a protected area.
1. Secure one screw into the wall. Install screw anchors if attaching
to drywall or masonry wall.
2. Slide the keyhole on top of the controller over the screw.
3. Secure the controller in place by installing screws in the holes
below the terminal strip.
Do not plug transformer into power source until control-
ler is mounted and all valve wiring has been connected.
CONNECTING VALVES AND TRANSFORMER
Installation of the XC should only be done by trained personnel.
1. Route valve wires between the control valve location and controller.
2. At valves, attach a common wire to either solenoid wire on all
valves. This is most commonly a white colored wire. Attach a
separate control wire to the remaining wire of each valve. All wire
connections should be done using waterproof connectors.
3. Route the valve wires through the conduit. Attach the conduit
through the bottom right side of the controller.
4. Secure the white valve common wire to the C (Common) screw on
the terminal strip. Attach each of the individual valve control wires
to the appropriate station terminals and tighten their screws.
5. Indoor Models: route the transformer cable through the hole on
the left side of the controller and connect the wires to the two
screws marked 24VAC.
Outdoor Models: transformer wires are already connected to the
AC terminals so all that is required is to connect primary power to
the junction box (see below).
E – High Voltage Wiring (Outdoor Model only)
NOTE: XC outdoor models are water and weather resis-
tant. Connecting the outdoor XC to primary AC power
should only be done by a licensed electrician following
all local codes. Improper installation could result in
shock or fire hazard.
1. Route AC power cable and conduit through the ½" (13mm) conduit
opening on the left side bottom of the cabinet.
2. Connect one wire to each of the two wires inside the junction box.
The ground wire should be connected to the green wire. Wire nuts
are provided to make these connections. Note: For E models
only: Connect the wires to the AC terminal block inside the junc-
tion box. AC supply wires must be 14 AWG (1.85 mm) or larger
with appropriate circuit breaker for the wire size. A switch or cir-
cuit-breaker shall be included in the building installation (in close
proximity to the controller, within easy reach of the operator) and
marked as the disconnecting device for the equipment.
3. Replace the junction box cover.
ACTIVATING THE BATTERY
After installing your XC make sure to remove the bat-
tery contact insulator to allow the XC to keep time in
the event of a power outage.
ENG
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter XC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter XC in the language / languages: English as an attachment in your email.

The manual is 3,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hunter XC

Hunter XC User Manual - German - 17 pages

Hunter XC Quick start guide - Dutch - 1 pages

Hunter XC User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info