801409
7
Zoom out
Zoom in
Previous page
1/35
Next page
3. Flowmeter location: Flow meters are installed between the master valve and zone
valves. To avoid false alerts, there should be no water taps or other uncontrolled water use
on the downstream side of the flow meter. If all solenoids connected to the controller are
not grouped together, it may be necessary to install more than one flow meter. For proper
installation and optimal water flow, use the chart below when determining pipe length. The
pipe bringing water into the flow meter needs to be 10 times longer than the width of the
pipe. The pipe carrying water away from the meter needs to be 5 times the width of the
pipe.
4. Cable (shielded direct-burial cable must be used): Two-wire cable is required. The
cable gauge is determined by the total length of cable between the controller and the flow
meter. The cable should consist of 2 dedicated wires and must not be in the same conduit
or cable bunch as the solenoid wires. Do not share the common wire of the solenoids with
the common of the sensors. If desired, the flex cable can be used to run inside the conduit.
That flex cable measures ¼” BSP, which also fits ¼” NPT.
IMPORTANT: Shielded direct-burial cable is commonly available. Manufacturers include
Paige Electric and Regency Wire.
The following instructions assume you have already
installed your Hydrawise controller
1. Flowmeter body: The flow meter has a marking on the body indicating the direction of
water flow. Installation of the flow meter must be in the correct orientation with water
flowing in the direction of the arrow on the flow meter body. All HC Flow Meters must be
installed horizontally with the dial facing upward.
Copyright 2023 Hunter Industries. All Rights Reserved. 7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter Hydrawise App at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter Hydrawise App in the language / languages: English as an attachment in your email.

The manual is 4.42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info