685907
93
Zoom out
Zoom in
Previous page
1/100
Next page
86
Message Description
IRRIGATION STOPPED BY
MAINT RADIO
Irrigation was stopped by
maintenance radio
PAUSE MODE SET BY
MAINT RADIO
Pause Mode set by
Maintenance Radio
PAUSE MODE CANCELLED
BY MAINT RADIO
Pause Mode cancelled by
Maintenance Radio
FCP MODE SET AT
CONTROLLER
FCP Mode set at controller
EVENT MODE SET AT
CONTROLLER
Event Mode set at
controller
FCP MODE SET BY
CENTRAL
FCP Mode set by central
EVENT MODE SET BY
CENTRAL
Event Mode set by central
PROG OFF CANCELLED AT
CONTROLLER
Programmable Off was
cancelled at controller
CUST MAN PROGRAM X
RESET BY CENTRAL
Custom Manual Program X
was reset by the central
ALL FCPs RESET BY
CENTRAL
All Field Controller
Programs (A to F) were
reset by central
ALL CUST PROGRAMS
RESET BY CENTRAL
All Customer Manual
Programs (1 to 4) were
reset by central
ALL STATION DATA RESET
BY CENTRAL
All station related data was
reset by central
ALL SSG DATA RESET BY
CENTRAL
All SSG related data was
reset by central
ALL P/MV DATA RESET BY
CENTRAL
All Pump/Master Valve
data was reset by central
ALL SENSOR DATA RESET
BY CENTRAL
All Sensor 1 to 4 data was
reset by central
ALL FLOW SENSOR DATA
RESET BY CENTRAL
All Flow Sensor data was
reset by central
FLOW ACCUMULATORS
RESET BY CENTRAL
All Flow Accumulators
were reset by central
FLOW TOTALS RESET BY
CENTRAL
All Flow Totals were reset
by central
TIME OR DATE CHANGED
AT CONTROLLER
The time and/or date was
changed at the controller
TIME OR DATE CHANGED
BY CENTRAL
The time and/or date was
changed by the central
STATION LOGS
Station Log records all station activity in the controller.
The Mode labels are the same as shown in the Run dial
position, when stations are running.
Mode Meaning
AUTO Automatic Field Controller Program (FCP)
AUTOEV Automatic System Event
MAN Manual Station/Program
CUST Custom Manual Program
MAN-EV Manual System Event
MRP Maintenance Radio Program
MRS Maintenance Radio Station
ICR ICR Program/Station
ETS ET System Program/Station
LEARN Learn Mode
TEST Test Program
PAUSE Paused Program/Station
SUSP Suspended Program/Station
The Status portion shows the type of event, or the reason
a station did not complete. Each start and stop of a station
is recorded. If a station has aPause or “Delayed event,
it does not necessarily indicate a malfunction. There are
several causes that may occur during normal irrigation.
Status Description
System Pause Pause issued by controller or central
System Susp Suspend issued by central
Sensor Pause Pause initiated from sensor activation
Sensor Susp Suspend initiated from sensor
activation
No Water Win Station ran into no water window
Complete Station completed run time
Delayed Soak completed
Interrupted Indicates that a station was
interrupted by pause/suspend
Max Sta Run Station could not run since max
stations were already running
Overcurrent Station shut down due to overcurrent
Stopped Station was stopped due to dial put in
Off, Stop Irrigation command received
or higher priority event
Man Sta Chg Station stopped due to manual station
advance
Flow Pause Irrigation was delayed due to flow
isolation process
ADM Flt Susp Irrigation was suspended due to an
ADM fault
Dec Com Fail Irrigation was stopped due to a comm
failure with decoder
93


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter ACC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter ACC in the language / languages: English as an attachment in your email.

The manual is 7,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hunter ACC

Hunter ACC User Manual - German - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info