The controller has 3 separate log files.
Each individual log has the date and time of the event at
the top of the screen.
Each type of log will show the most recent event first.
Use the + and buttons to step through events, forward or
backward.
Alarm Log tracks all unusual events that require attention.
The Attention display (or “Fault, in earlier versions) that
appears when the dial is in the Run position will almost
always have one or more corresponding Alarm Log
entries, with more detail. Turn the dial to Data History and
select Alarm Log whenever an ATTENTION display occurs.
Controller Log tracks general changes or occurrences for
the controller. Most of these are not alarm events.
Station Log tracks all station activity, including normal
and abnormal activity. It can be used simply to verify
whether irrigation occurred, or used as part of the
diagnostic process.
ALARM LOG MESSAGES
Sensor State Change Sensor changed state (Closed/
Open)
Missed Irrigation A station missed irrigating
Power Outage Controller or facepack power was
lost
Power Restore Controller or facepack power was
restored
ADM Fault A fault was reported by ADM
Pump Fault A pump decoder reported a fault
Station Fault A station decoder reported a fault
Pump Dec Failure A pump decoder failed
Sta Dec Failure A station decoder failed
Sensor Decoder A sensor decoder reported a fault
Alarm Log, Missed Irrigation “Mode Labels
Mode appears when a station failed to complete irrigation
for some reason, and indicates why the station was
supposed be running in the first place.
Scheduled Station was running as part of an
automatic Field Controller Program (FCP)
(A, B, C, D, E, or F)
System
Event
Station was running as a System
Automatic Event
Manual Prg
All
Station was running as part of a Manual
All Stations Program
Custom
Manual
Station was running as part of a Custom
Manual Program
Manual
Station
Station was running as a Manual One
Station
SME Station was running as a System Manual
Event
MR
Program
Station was running as part of a
Manual All Stations program started by
Maintenance Radio
MR SSG Station was running as part of a SSG
started by MR
MR Station Station was running as a Manual One
Station started by MR
ICR
Program
Station was running as part of a Manual
All Stations program started by ICR
remote
ICR Station Station was running as a Manual One
Station started by ICR
ETS Progam Station was running as part of a Manual
All Stations started by ET System
ETS Station Station was running as a Manual One
Station started by ET System
Learn Event Station was running as part of the Learn
process
Test Event Station was running as part of the Test
program
aCC/aGC loG messaGes .............................................................
91


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter ACC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter ACC in the language / languages: English as an attachment in your email.

The manual is 7,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hunter ACC

Hunter ACC User Manual - German - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info