For experienced operators, the fastest steps to initial
programming are as follows.
1. Set Current Date/Time: Use the arrow buttons to
navigate, and the +/- buttons to change. Set the Date
and Time and choose Units of Measure.
2. Set Watering Start Time: Each automatic Program
has 10 start times. At this position, use the
Programs button to select individual programs,
and the 10 possible start times for that program will
appear. Use arrows to navigate and +/- to change
See SETTING PROGRAM OVERLAP OPTIONS on
page 36 for more information..
3. Set Station Run Times: At this dial position, use
the Programs button to select the program you are
setting up. Then, use the +/- buttons to change the
hours:minutes:seconds run time for each station.
Use the up and down arrows to move to the next
station. TIP: Use the Copy and Paste buttons to move
quickly through large numbers of similar stations.
Set the first station’s run time, then press Copy. Use
the Up arrow to move to the next station, and press
Paste.
4. Set Days to Water: Use the Programs button to
select the Program. Use the arrows to move to Day
Sched, and choose Schedule Type (Day of Week,
Interval, or Odd/Even).
5. Set Pump Operation (optional): The two Pump/
Master Valve outputs may be set by station at this
position. If no pump or Master Valve is in use, this is
not required.
CELLULAR/GSM (ACC-COM-GSM, GSM-E)
GSM cellular service must have reliable coverage at
installed site.
GSM service must permit and provide Circuit Switched
Data (CSD). IMMS 2.0 connections require CSD and will
use the Data telephone number. No other form of cellular
communications will work. There are no CDMA options for
ACC communications at this time.
UHF RADIO
All UHF radio communications require a license.
All radio communications for ACC work with RAD3 radio
module or later. IMMSR radios, designed for original
IMMS Site Interfaces and Controller Interfaces, will NOT
work with ACC controllers.
poWer faIlures ........................................................................
The ACC’s real time clock is independent of external power
or the 9 VDC battery, and will keep time during a power
failure of virtually any length. When external power is
restored, the ACC will still have the correct time and will
be ready to irrigate.
QuICK sTarT ................................................................................
A Power Outage message will be stored in the Alarm Log,
with time of the outage. Another log is stored when power
is restored.
RAD3 radios are not supplied with antennas, but an
antenna must be provided for the radio to operate, and the
antenna must be installed outside of any metal enclosure
(including the ACC metal cabinet).
Radio communications for the ACC are only to
communicate with other ACCs, and do not provide
communications directly with a central computer. This
should be established with an IMMS-CCC and a hardwire
interface, or by telephone using ACC-COM-POTS or
ACC-COM-GSM (or GSM-E for international applications).
For golf applications using Surveyopr central control
software only, the AGCHUBR provides a direct radio
interface to all radio-equipped ACC/AGC controllers.
See Hunters ACC System Design Guide for important
details regarding design of central control systems.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter ACC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter ACC in the language / languages: English as an attachment in your email.

The manual is 7,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hunter ACC

Hunter ACC User Manual - German - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info